Accuracy and Repeatability of the Polar® RS800sd to Evaluate Stride Rate and Running Speed

The purpose of this study was to evaluate the accuracy and the repeatability of a new running computer system (RS800sd, Polar, Kempele, Finland) which included the measurement of running speed (RS) and stride rate (SR). Eight well-trained triathletes participated in this study. First, they completed an incremental continuous maximum test on a treadmill (from 12 km x h (-1) to 18 km x h (-1)) at 0% grade. Then the subjects took part in a second test to determine RS800sd intra-reproducibility to evaluate running speed. They ran twice during 5 min at a pace corresponding to their maximal lactate steady-state. During these two tests, RS and SR were recorded by the RS800sd system, by an optical sensor system (for RS) and a force-sensitive device (for SR). No difference was found between the RS800sd system and the reference systems both for RS (ICC=0.95) and SR (ICC=0.69). Moreover RS measures were statistically repeatable. This study provided evidence for the validity of the RS800sd system for measuring the kinematic characteristics of running (speed and frequency). Further investigations are needed to replicate these findings at lower running speeds, notably during walking to assess its capacity to evaluate physical activity in natural conditions.

[1]  P. Högberg How do stride length and stride frequency influence the energy-output during running? , 2004, Arbeitsphysiologie.

[2]  J. D. Janssen,et al.  Assessment of energy expenditure for physical activity using a triaxial accelerometer. , 1994, Medicine and science in sports and exercise.

[3]  P. Douglas,et al.  Use of heart rate monitors by endurance athletes: lessons from triathletes. , 1998, The Journal of sports medicine and physical fitness.

[4]  Shauna L. Stephens,et al.  Accuracy of SRM and power tap power monitoring systems for bicycling. , 2004, Medicine and science in sports and exercise.

[5]  Ann C. Snyder,et al.  A simplified approach to estimating the maximal lactate steady state. , 1994 .

[6]  D. Bentley,et al.  Portable gas analyser Cosmed K4b2 compared to a laboratory based mass spectrometer system. , 2005, The Journal of sports medicine and physical fitness.

[8]  Ross Tucker,et al.  An analysis of pacing strategies during men's world-record performances in track athletics. , 2006, International journal of sports physiology and performance.

[9]  R. C. Berger,et al.  Voluntary pacing and energy cost of off-road cycling and running. , 2000, Applied ergonomics.

[10]  Karsten Froberg,et al.  Reexamination of validity and reliability of the CSA monitor in walking and running. , 2003, Medicine and science in sports and exercise.

[11]  Scott E Crouter,et al.  Validity of 10 electronic pedometers for measuring steps, distance, and energy cost. , 2003, Medicine and science in sports and exercise.

[12]  R J Gregor,et al.  Biomechanics of distance running: a longitudinal study. , 1976, Research quarterly.

[13]  G. Atkinson,et al.  Science and cycling: current knowledge and future directions for research , 2003, Journal of sports sciences.

[14]  J P Koralsztein,et al.  Effect of free versus constant pace on performance and oxygen kinetics in running. , 2001, Medicine and science in sports and exercise.

[15]  M. Saito,et al.  Temporal patterns in running , 1974 .

[16]  C Hausswirth,et al.  Physiological Demands of Running During Long Distance Runs and Triathlons , 2001, Sports medicine.

[17]  R. Eston,et al.  Effect of stride length on symptoms of exercise‐induced muscle damage during a repeated bout of downhill running , 2000, Scandinavian journal of medicine & science in sports.

[18]  C. Worringham,et al.  Assessment of speed and position during human locomotion using nondifferential GPS. , 2008, Medicine and science in sports and exercise.

[19]  J. A. Hanson,et al.  Fatigue effects on patterns of movement. , 1971, Ergonomics.

[20]  Elliott Bc,et al.  A biomechanical evaluation of the role of fatigue in middle-distance running. , 1980 .

[21]  David T. Martin,et al.  Evaluation of the Lactate Pro blood lactate analyser , 2000, European Journal of Applied Physiology.

[22]  C. R. Taylor,et al.  Force development during sustained locomotion: a determinant of gait, speed and metabolic power. , 1985, The Journal of experimental biology.

[23]  Shirley Bryan,et al.  Validity of the Actical accelerometer step-count function. , 2007, Medicine and science in sports and exercise.

[24]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[25]  Y Schutz,et al.  Assessment of speed of human locomotion using a differential satellite global positioning system. , 2000, Medicine and science in sports and exercise.

[26]  G. Cavagna,et al.  The sources of external work in level walking and running. , 1976, The Journal of physiology.

[27]  J. Brisswalter,et al.  Effect of cycling cadence on subsequent 3 km running performance in well trained triathletes , 2003, British journal of sports medicine.

[28]  Scott E Crouter,et al.  Accuracy of polar S410 heart rate monitor to estimate energy cost of exercise. , 2004, Medicine and science in sports and exercise.

[29]  E. Howley,et al.  Criteria for maximal oxygen uptake: review and commentary. , 1995, Medicine and science in sports and exercise.

[30]  David J Smith,et al.  Performance Evaluation of Swimmers , 2002, Sports medicine.

[31]  Ross Tucker,et al.  The Role of Information Processing Between the Brain and Peripheral Physiological Systems in Pacing and Perception of Effort , 2006, Sports medicine.

[32]  I. Hunter,et al.  Preferred and optimal stride frequency, stiffness and economy: changes with fatigue during a 1-h high-intensity run , 2007, European Journal of Applied Physiology.

[33]  T. Noakes,et al.  Neuromuscular factors determining 5 km running performance and running economy in well-trained athletes , 2006, European Journal of Applied Physiology.