Quantitative dynamic contrast‐enhanced MRI for mouse models using automatic detection of the arterial input function

Dynamic contrast‐enhanced MRI (DCE‐MRI) is widely accepted for the evaluation of cancer. DCE‐MRI, a noninvasive measurement of microvessel permeability, blood volume and blood flow, is extremely useful for understanding disease mechanisms and monitoring therapeutic responses in preclinical research. For the accurate quantification of pharmacokinetic parameters using DCE‐MRI, determination of the arterial input function (AIF) from a large arterial vessel near the tumor is required. However, a manual determination of AIF in mouse MR images is often difficult because of the small spatial dimensions or the location of the tumor. In this study, we propose an algorithm for the automatic detection of AIF from mouse DCE‐MR images using Kendall's coefficient of concordance. The proposed method was tested with computer simulations and then applied to tumor‐bearing mice (n = 8). Results from computer simulations showed that the proposed algorithm is capable of categorizing simulated AIF signals according to their noise levels. We found that the resulting pharmacokinetic parameters computed from our method were comparable with those from the manual determination of AIF, with acceptable differences in Ktrans (5.14 ± 3.60%), ve (6.02 ± 3.22%), vp (5.10 ± 7.05%) and kep (5.38 ± 4.72%). The results of the current study suggest the usefulness of an automatically defined AIF using Kendall's coefficient of concordance for quantitative DCE‐MRI in mouse models for cancer evaluation. Copyright © 2011 John Wiley & Sons, Ltd.

[1]  Areen K. Al-Bashir,et al.  Dynamic contrast-enhanced magnetic resonance imaging of vascular changes induced by sunitinib in papillary renal cell carcinoma xenograft tumors. , 2009, Neoplasia.

[2]  W C Eckelman,et al.  Pharmacokinetic analysis of blood distribution of intravenously administered 153Gd-labeled Gd(DTPA)2- and 99mTc(DTPA) in rats. , 1990, Magnetic resonance imaging.

[3]  B. Rosen,et al.  High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis , 1996, Magnetic resonance in medicine.

[4]  O Henriksen,et al.  Quantitation of blood‐brain barrier defect by magnetic resonance imaging and gadolinium‐DTPA in patients with multiple sclerosis and brain tumors , 1990, Magnetic resonance in medicine.

[5]  Tony F. Chan,et al.  Active contours without edges , 2001, IEEE Trans. Image Process..

[6]  Jianhua Yao,et al.  Automatic Determination of Arterial Input Function for Dynamic Contrast Enhanced MRI in Tumor Assessment , 2008, MICCAI.

[7]  P. Tofts,et al.  Measurement of the blood‐brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts , 1991, Magnetic resonance in medicine.

[8]  R W Cox,et al.  AFNI: software for analysis and visualization of functional magnetic resonance neuroimages. , 1996, Computers and biomedical research, an international journal.

[9]  C. Cuénod,et al.  Epithelial ovarian tumors: value of dynamic contrast-enhanced MR imaging and correlation with tumor angiogenesis. , 2008, Radiology.

[10]  Edward F. Jackson,et al.  A phase I surrogate endpoint study of SU6668 in patients with solid tumors , 2004, Investigational New Drugs.

[11]  K. Murase,et al.  Determination of arterial input function using fuzzy clustering for quantification of cerebral blood flow with dynamic susceptibility contrast‐enhanced MR imaging , 2001, Journal of magnetic resonance imaging : JMRI.

[12]  Yingli Lu,et al.  Regional homogeneity approach to fMRI data analysis , 2004, NeuroImage.

[13]  Egill Rostrup,et al.  Partial volume effect (PVE) on the arterial input function (AIF) in T1‐weighted perfusion imaging and limitations of the multiplicative rescaling approach , 2009, Magnetic resonance in medicine.

[14]  J. Djurhuus,et al.  In vivo measurements of relaxivities in the rat kidney cortex , 2000, Journal of magnetic resonance imaging : JMRI.

[15]  R. Zhou,et al.  MRI estimation of the arterial input function in mice. , 2003, Academic radiology.

[16]  A. Crespo,et al.  Morphological and haematological parameters in the Algerian mouse (Mus spretus) inhabiting an area contaminated with heavy metals. , 2001, Environmental pollution.

[17]  N J Pelc,et al.  Rapid calculation of T1 using variable flip angle gradient refocused imaging. , 1987, Magnetic resonance imaging.

[18]  R. Forthofer,et al.  Rank Correlation Methods , 1981 .

[19]  D. Altman,et al.  Measuring agreement in method comparison studies , 1999, Statistical methods in medical research.

[20]  Søren Christensen,et al.  Automatic selection of arterial input function using cluster analysis , 2006, Magnetic resonance in medicine.

[21]  J. Engelbach,et al.  Magnetic resonance imaging defines cervicovaginal anatomy, cancer, and VEGF trap antiangiogenic efficacy in estrogen-treated K14-HPV16 transgenic mice. , 2009, Cancer research.

[22]  F Frouin,et al.  Reduced capillary perfusion and permeability in human tumour xenografts treated with the VEGF signalling inhibitor ZD4190: an in vivo assessment using dynamic MR imaging and macromolecular contrast media. , 2003, Magnetic resonance imaging.

[23]  M. Wendland,et al.  Vascular permeability during antiangiogenesis treatment: MR imaging assay results as biomarker for subsequent tumor growth in rats. , 2008, Radiology.

[24]  Geoffrey J M Parker,et al.  Comparison of model‐based arterial input functions for dynamic contrast‐enhanced MRI in tumor bearing rats , 2009, Magnetic resonance in medicine.

[25]  Tianzi Jiang,et al.  Regional coherence changes in the early stages of Alzheimer’s disease: A combined structural and resting-state functional MRI study , 2007, NeuroImage.

[26]  V. Haughton,et al.  Automatic calculation of the arterial input function for cerebral perfusion imaging with MR imaging. , 2003, Radiology.

[27]  L R Schad,et al.  Pharmacokinetic parameters in CNS Gd-DTPA enhanced MR imaging. , 1991, Journal of computer assisted tomography.

[28]  W. J. Lorenz,et al.  Pharmacokinetic Mapping of the Breast: A New Method for Dynamic MR Mammography , 1995, Magnetic resonance in medicine.