Evaluating the effect of coating equipment on tablet film quality using terahertz pulsed imaging.

In this study, terahertz pulsed imaging (TPI) was employed to investigate the effect of the coating equipment (fluid bed and drum coater) on the structure of the applied film coating and subsequent dissolution behaviour. Six tablets from every batch coated with the same delayed release coating formulation under recommended process conditions (provided by the coating polymer supplier) were mapped individually to evaluate the effect of coating device on critical coating characteristics (coating thickness, surface morphology and density). Although the traditional coating quality parameter (weight gain) indicated no differences between both batches, TPI analysis revealed a lower mean coating thickness (CT) for tablets coated in the drum coater compared to fluid bed coated tablets (p<0.05). Moreover, drum coated tablets showed a more pronounced CT variation between the two sides and the centre band of the biconvex tablets, with the CT around the centre band being 22.5% thinner than the top and bottom sides for the drum coated tablets and 12.5% thinner for fluid bed coated tablets. The TPI analysis suggested a denser coating for the drum coated tablets. Dissolution testing confirmed that the film coating density was the drug release governing factor, with faster drug release for tablets coated in the fluid bed coater (98 ± 4% after 6h) compared to drum coated tablets (72 ± 6% after 6h). Overall, TPI investigation revealed substantial differences in the applied film coating quality between tablets coated in the two coaters, which in turn correlated with the subsequent dissolution performance.

[1]  Rasmus Bro,et al.  Increasing process understanding by analyzing complex interactions in experimental data. , 2009, Journal of pharmaceutical sciences.

[2]  Yaochun Shen,et al.  Elimination of scattering effects in spectral measurement of granulated materials using terahertz pulsed spectroscopy , 2008 .

[3]  F. Podczeck COMPARISON OF IN-VITRO DISSOLUTION PROFILES BY CALCULATING MEAN DISSOLUTION TIME (MDT) OR MEAN RESIDENCE TIME (MRT) , 1993 .

[4]  P. Costa,et al.  An alternative method to the evaluation of similarity factor in dissolution testing. , 2001, International journal of pharmaceutics.

[5]  J. Kauffman,et al.  Raman spectroscopy of coated pharmaceutical tablets and physical models for multivariate calibration to tablet coating thickness. , 2007, Journal of pharmaceutical and biomedical analysis.

[6]  P. Taday,et al.  Terahertz pulsed spectroscopy and imaging in the pharmaceutical setting ‐ a review , 2007, The Journal of pharmacy and pharmacology.

[7]  Yaochun Shen,et al.  Analysis of coating structures and interfaces in solid oral dosage forms by three dimensional terahertz pulsed imaging. , 2007, Journal of pharmaceutical sciences.

[8]  R. Reed,et al.  Rapid at-line analysis of coating thickness and uniformity on tablets using laser induced breakdown spectroscopy. , 2002, Journal of pharmaceutical and biomedical analysis.

[9]  Yaochun Shen,et al.  Monitoring the film coating unit operation and predicting drug dissolution using terahertz pulsed imaging. , 2009, Journal of pharmaceutical sciences.

[10]  Kenneth R. Morris,et al.  Quantitative analysis of film coating in a pan coater based on in-line sensor measurements , 2005, AAPS PharmSciTech.

[11]  Stuart C. Porter Scale-Up of Film Coating , 2001 .

[12]  Yaochun Shen,et al.  Delayed release tablet dissolution related to coating thickness by terahertz pulsed image mapping. , 2008, Journal of pharmaceutical sciences.

[13]  Kirk E. Wilson,et al.  The Influence of Tablet Shape and Pan Speed on Intra-tablet Film Coating Uniformity , 1997 .

[14]  M Pepper,et al.  Analysis of sustained-release tablet film coats using terahertz pulsed imaging. , 2007, Journal of controlled release : official journal of the Controlled Release Society.

[15]  Y. Roggo,et al.  Characterizing process effects on pharmaceutical solid forms using near-infrared spectroscopy and infrared imaging. , 2005, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[16]  Carl Wassgren,et al.  Intra-tablet coating variability for several pharmaceutical tablet shapes , 2011 .

[17]  Yaochun Shen,et al.  Applications of terahertz pulsed imaging to sustained-release tablet film coating quality assessment and dissolution performance. , 2008, Journal of controlled release : official journal of the Controlled Release Society.

[18]  Yaochun Shen,et al.  Investigating dissolution performance critical areas on coated tablets: a case study using terahertz pulsed imaging. , 2010, Journal of pharmaceutical sciences.

[19]  Robert Gurny,et al.  Terahertz pulsed imaging, a novel process analytical tool to investigate the coating characteristics of push-pull osmotic systems. , 2010, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[20]  Rowe Rc Gloss measurement on film coated tablets , 1985 .

[21]  J. Torrado,et al.  Effect of drug release rate on bioavailability of different aspirin tablets , 1996 .

[22]  Jukka Rantanen,et al.  Building quality into a coating process , 2009, Pharmaceutical development and technology.

[23]  M. Aulton,et al.  Pharmaceutical Coating Technology , 1995 .

[24]  Gabriele Reich,et al.  Near-infrared spectroscopy and imaging: basic principles and pharmaceutical applications. , 2005, Advanced drug delivery reviews.

[25]  J. Rantanen,et al.  Tablet surface characterisation by various imaging techniques. , 2003, International journal of pharmaceutics.

[26]  Vincent P. Wallace,et al.  Terahertz pulsed imaging of knee cartilage , 2010, Biomedical optics express.

[27]  M. E. Aulton,et al.  Assessment of the Thickness Variation and Surface Roughness of Aqueous Film Coated Tablets Using a Light-Section Microscope , 1995 .

[28]  R. Rowe Gloss measurement on film coated tablets , 1985, The Journal of pharmacy and pharmacology.

[29]  R. Rowe Tablet-tablet contact and mutual rubbing within a coating drum — an important factor governing the properties and appearance of tablet film coatings , 1988 .

[30]  Shuncong Zhong,et al.  Terahertz in-line sensor for direct coating thickness measurement of individual tablets during film coating in real-time. , 2011, Journal of pharmaceutical sciences.