Blood trauma induced by clinically accepted oxygenators.

Hemolysis remains one of the most serious problems during cardiopulmonary bypass (CPB), extracorporeal membrane oxygenation (ECMO), and percutaneous cardiopulmonary support (PCPS). However, the hemolytic characteristics associated with oxygenators are not well defined. A specialized hemolysis test protocol for oxygenators was developed. A comparative study was performed following this protocol to determine the hemolytic characteristics of the clinically available oxygenators during CPB; pressure drop measurements in the blood chamber were also performed. Four oxygenators (Medtronic Affinity, Cobe Optima, Terumo Capiox SX25, and Bard Quantum) were evaluated. Fresh blood from healthy Dexter calves anticoagulated with citrate phosphate dextrose adenine solution was used. The blood flow was fixed at 5 L/min, similar to that used in CPB. The Normalized Index of Hemolysis for Oxygenators (NIHO) has been modified according to the American Society of Testing and Materials (ASTM) standards. The NIH value, which was obtained from the circuit without an oxygenator, was subtracted from the primary NIH value, obtained from the circuit with an oxygenator to eliminate the effects of a centrifugal pump or other artifacts. The NIHO value was the lowest in the Affinity (0.0116 ± 0.0017) and increased from Affinity < Optima (0.0270 ± 0.0038) < Capiox (0.0335 ± 0.0028) < Quantum (0.0416 ± 0.0015 g/100 L). The Optima and Capiox did not demonstrate a significant difference. In addition, this NIHO value has a close relationship to the pressure drop. In conclusion, this new evaluation method is suitable to compare the biocompatibility performance of different types of clinically available oxygenators for CPB usage.

[1]  V. Videm,et al.  Biocompatibility of extracorporeal circulation. In vitro comparison of heparin-coated and uncoated oxygenator circuits. , 1991, The Journal of thoracic and cardiovascular surgery.

[2]  Yukihiko Nosé,et al.  Effect of surface roughness on hemolysis in a centrifugal blood pump. , 1996 .

[3]  Y Nosé,et al.  Hemolysis in different centrifugal pumps. , 2008, Artificial organs.

[4]  E. Fosse,et al.  Reduced complement activation with heparin-coated oxygenator and tubings in coronary bypass operations. , 1992, The Journal of thoracic and cardiovascular surgery.

[5]  Y. Nosé,et al.  COMPARISON OF PROTEIN ADSORPTION AND PLATELET ADHESION ON THE SURFACE OF OXYGENATOR MEMBRANES , 1997 .

[6]  J. Linneweber,et al.  Preclinical Evaluation of a Hollow Fiber Silicone Membrane Oxygenator for Extracorporeal Membrane Oxygenator Application , 2000, ASAIO journal.

[7]  L. Foubert,et al.  Impact of oxygenator design on hemolysis, shear stress, and white blood cell and platelet counts. , 1996, Journal of cardiothoracic and vascular anesthesia.

[8]  Y. Nosé,et al.  Comparison of the Gyro C1E3 and BioMedicus centrifugal pump performances during cardiopulmonary bypass. , 1997, Artificial organs.

[9]  Y. Ohara,et al.  Hemolytic characteristics of a pivot bearing supported Gyro centrifugal pump (C1E3) simulating various clinical applications. , 1996, Artificial organs.

[10]  Y. Shomura,et al.  Clinical Evaluation of a Silicone Coated Hollow Fiber Oxygenator , 1997, ASAIO journal.

[11]  T Koller,et al.  Contribution to the in vitro testing of pumps for extracorporeal circulation. , 1967, The Journal of thoracic and cardiovascular surgery.

[12]  Y. Nosé,et al.  Development of an antithrombogenic and antitraumatic blood pump: the Gyro C1E3. , 2000, ASAIO journal.

[13]  J. Hayashi,et al.  Biocompatibility of a silicone-coated polypropylene hollow fiber oxygenator in an in vitro model. , 1999, The Annals of thoracic surgery.