A voltage-based observer design for membrane water content in PEM fuel cells

This paper presents a scheme for estimating membrane water content in polymer electrolyte membrane (PEM) fuel cells from voltage, current, temperature, and several pressure measurements. The approach is to exploit the resistive voltage drop which is closely associated with membrane water content. To distinguish this resistive drop from other voltage losses we make use of a well-developed fuel cell voltage model that characterizes each loss term, as well as the open circuit voltage. The unmeasured hydrogen and oxygen partial pressure values in the open-circuit model are estimated with a variant of the hydrogen and oxygen observers developed by M. Arcak et al. (2004). Preliminary experimental results, obtained at the Connecticut Global Fuel Cell Center, are presented and discussed.

[1]  T. Springer,et al.  Polymer Electrolyte Fuel Cell Model , 1991 .

[2]  Effect of collector plate resistance on fuel cell stack performance , 1998 .

[3]  R. S. Glass,et al.  Sensor Needs and Requirements for Fuel Cells and CIDI/SIDI Engines , 2000 .

[4]  James Larminie,et al.  Fuel Cell Systems Explained , 2000 .

[5]  Petar V. Kokotovic,et al.  Nonlinear observers: a circle criterion design and robustness analysis , 2001, Autom..

[6]  F. Büchi,et al.  Investigation of the Transversal Water Profile in Nafion Membranes in Polymer Electrolyte Fuel Cells , 2001 .

[7]  B. Andreaus,et al.  Analysis of performance losses in polymer electrolyte fuel cells at high current densities by impedance spectroscopy , 2002 .

[8]  Trung Van Nguyen,et al.  Diagnostic Tool to Detect Electrode Flooding in Proton-Exchange-Membrane Fuel Cells , 2003 .

[9]  James Larminie,et al.  Fuel Cell Systems Explained: Larminie/Fuel Cell Systems Explained , 2003 .

[10]  Chao-Yang Wang,et al.  In situ water distribution measurements in a polymer electrolyte fuel cell , 2003 .

[11]  M. D. Rooij,et al.  Electrochemical Methods: Fundamentals and Applications , 2003 .

[12]  S. Bortoff,et al.  Nonlinear observer design for fuel processing reactors in fuel cell power systems , 2004, Proceedings of the 2004 American Control Conference.

[13]  Murat Arcak,et al.  A nonlinear observer design for fuel cell hydrogen estimation , 2004, IEEE Transactions on Control Systems Technology.

[14]  Denise A. McKay,et al.  Measurement of Liquid Water Accumulation in a PEMFC with Dead-Ended Anode , 2008 .

[15]  Frano Barbir,et al.  Relationship between pressure drop and cell resistance as a diagnostic tool for PEM fuel cells , 2005 .