Electromagnetic (EM) catheter path tracking in ultrasound-guided brachytherapy of the breast

To evaluate a novel navigation system for breast brachytherapy, based on ultrasound (US)-guided catheter needle implantations followed by electromagnetic (EM) tracking of catheter paths. Breast phantoms were produced, containing US–visible tumors. Ultrasound was used to localize the tumor pose and volume within the phantom, followed by planning an optimal catheter pattern through the tumor using navigation software. An electromagnetic (EM)-tracked catheter needle was used to insert the catheters in the desired pattern. The inserted catheters were visualized on a post-implant CT, serving as ground truth. Electromagnetic (EM) tracking and reconstruction of the inserted catheter paths were performed by pulling a flexible EM guidewire through each catheter, performed in two clinical brachytherapy suites. The accuracy of EM catheter tracking was evaluated by calculating the Hausdorff distance between the EM-tracked and CT-based catheter paths. The accuracy and clinical feasibility of EM catheter tracking were also evaluated in three breast cancer patients, performed in a separate experiment room. A total of 71 catheter needles were implanted into 12 phantoms using US guidance and EM navigation, in an average ± SD time of 8.1 ± 2.9 min. The accuracy of EM catheter tracking was dependent on the brachytherapy suite: 2.0 ± 1.2 mm in suite 1 and 0.6 ± 0.2 mm in suite 2. EM catheter tracking was successfully performed in three breast brachytherapy patients. Catheter tracking typically took less than 5 min and had an average accuracy of 1.7 ± 0.3 mm. Our preliminary results show a potential role for US guidance and EM needle navigation for implantation of catheters for breast brachytherapy. EM catheter tracking can accurately assess the implant geometry in breast brachytherapy patients. This methodology has the potential to evaluate catheter positions directly after the implantation and during the several fractions of the treatment.

[1]  Thomas R Mackie,et al.  A dosimetric comparison of accelerated partial breast irradiation techniques: multicatheter interstitial brachytherapy, three-dimensional conformal radiotherapy, and supine versus prone helical tomotherapy. , 2007, International journal of radiation oncology, biology, physics.

[2]  Lawrence B Marks,et al.  Accelerated partial breast irradiation consensus statement from the American Society for Radiation Oncology (ASTRO). , 2009, Journal of the American College of Surgeons.

[3]  Aaron Fenster,et al.  A compact mechatronic system for 3D ultrasound guided prostate interventions. , 2011, Medical physics.

[4]  Milan Sonka,et al.  3D Slicer as an image computing platform for the Quantitative Imaging Network. , 2012, Magnetic resonance imaging.

[5]  Andras Lasso,et al.  Navigated Breast Tumor Excision Using Electromagnetically Tracked Ultrasound and Surgical Instruments , 2016, IEEE Transactions on Biomedical Engineering.

[6]  Gabor Fichtinger,et al.  Needle Navigation and Catheter Reconstruction for Breast Brachytherapy Using Open Source Software , 2019, Acta Polytechnica Hungarica.

[7]  Alphonse G. Taghian,et al.  Accelerated Partial Breast Irradiation: Executive summary for the update of an ASTRO Evidence-Based Consensus Statement. , 2017, Practical radiation oncology.

[8]  Ehsan Dehghan,et al.  Electromagnetic tracking for catheter reconstruction in ultrasound-guided high-dose-rate brachytherapy of the prostate. , 2014, Brachytherapy.

[9]  Gabor Fichtinger,et al.  OpenIGTLink: an open network protocol for image‐guided therapy environment , 2009, The international journal of medical robotics + computer assisted surgery : MRCAS.

[10]  Paul Kessler,et al.  Needle tip tracking for ultrasound‐guided peripheral nerve block procedures—An observer blinded, randomised, controlled, crossover study on a phantom model , 2019, Acta anaesthesiologica Scandinavica.

[11]  Michael C Kirk,et al.  A dosimetric comparison of three-dimensional conformal, intensity-modulated radiation therapy, and MammoSite partial-breast irradiation. , 2006, Brachytherapy.

[12]  Christoph Bert,et al.  Electromagnetic tracking (EMT) technology for improved treatment quality assurance in interstitial brachytherapy , 2017, Journal of applied clinical medical physics.

[13]  F. Vicini,et al.  Accelerated partial breast irradiation: a dosimetric comparison of three different techniques. , 2005, Brachytherapy.

[14]  Andras Lasso,et al.  PLUS: Open-Source Toolkit for Ultrasound-Guided Intervention Systems , 2014, IEEE Transactions on Biomedical Engineering.

[15]  Christoph Bert,et al.  Assessment of the implant geometry in fractionated interstitial HDR breast brachytherapy using an electromagnetic tracking system. , 2017, Brachytherapy.

[16]  Jun Zhou,et al.  Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: a preliminary performance study. , 2013, Medical physics.

[17]  Nikolaos K. Uzunoglu,et al.  CT-based software for 3-D localization and reconstruction in stepping source brachytherapy , 1997, IEEE Transactions on Information Technology in Biomedicine.

[18]  G. Marinello,et al.  Paris System for Interstitial Brachytherapy , 2009 .