Physical validation of a patient-specific contact finite element model of the ankle.

A validation study was conducted to determine the extent to which computational ankle contact finite element (FE) results agreed with experimentally measured tibio-talar contact stress. Two cadaver ankles were loaded in separate test sessions, during which ankle contact stresses were measured with a high-resolution (Tekscan) pressure sensor. Corresponding contact FE analyses were subsequently performed for comparison. The agreement was good between FE-computed and experimentally measured mean (3.2% discrepancy for one ankle, 19.3% for the other) and maximum (1.5% and 6.2%) contact stress, as well as for contact area (1.7% and 14.9%). There was also excellent agreement between histograms of fractional areas of cartilage experiencing specific ranges of contact stress. Finally, point-by-point comparisons between the computed and measured contact stress distributions over the articular surface showed substantial agreement, with correlation coefficients of 90% for one ankle and 86% for the other. In the past, general qualitative, but little direct quantitative agreement has been demonstrated with articular joint contact FE models. The methods used for this validation enable formal comparison of computational and experimental results, and open the way for objective statistical measures of regional correlation between FE-computed contact stress distributions from comparison articular joint surfaces (e.g., those from an intact versus those with residual intra-articular fracture incongruity).

[1]  R Huiskes,et al.  The biomechanics of the human patella during passive knee flexion. , 1995, Journal of biomechanics.

[2]  Thomas D. Brown,et al.  Finite Element Modeling in Musculoskeletal Biomechanics , 2004 .

[3]  Thomas D Brown,et al.  New methods for assessing cartilage contact stress after articular fracture. , 2004, Clinical orthopaedics and related research.

[4]  Thomas D Brown,et al.  Tensile Engagement of the Peri-Ankle Ligaments in Stance Phase , 2005, Foot & ankle international.

[5]  A. Palmer,et al.  Pressure distribution in the distal radioulnar joint. , 1998, The Journal of hand surgery.

[6]  M. Baratz,et al.  Displaced intra-articular fractures of the distal radius: the effect of fracture displacement on contact stresses in a cadaver model. , 1996, The Journal of hand surgery.

[7]  M. Hull,et al.  How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint. , 2003, Journal of biomechanics.

[8]  A. Tencer,et al.  Effects of intra-articular distal radius depression on wrist joint contact characteristics. , 1996, The Journal of hand surgery.

[9]  T D Brown,et al.  Chronic stress tolerance levels for human articular cartilage: two nonuniform contact models applied to long-term follow-up of CDH. , 1995, Journal of biomechanics.

[10]  T D Brown,et al.  Some effects of global joint morphology on local stress aberrations near imprecisely reduced intra-articular fractures. , 1990, Journal of biomechanics.

[11]  E. Akelman,et al.  An Experimental Model of Femoral Condylar Defect Leading to Osteoarthrosis , 1993, Journal of orthopaedic trauma.

[12]  Donald D Anderson,et al.  A three-dimensional finite element model of the radiocarpal joint: distal radius fracture step-off and stress transfer. , 2005, The Iowa orthopaedic journal.

[13]  T. Brown,et al.  Articulated external fixation of the ankle: minimizing motion resistance by accurate axis alignment. , 1999, Journal of biomechanics.

[14]  Freddie H. Fu,et al.  Intraarticular Contact Stresses with Simulated Ankle Malunions , 1994, Journal of orthopaedic trauma.

[15]  Thomas D Brown,et al.  Intra-articular Contact Stress Distributions at the Ankle Throughout Stance Phase–patient-specific Finite Element Analysis as a Metric of Degeneration Propensity , 2006, Biomechanics and modeling in mechanobiology.

[16]  R. Brand,et al.  Joint contact stress: a reasonable surrogate for biological processes? , 2005, The Iowa orthopaedic journal.

[17]  A Leardini,et al.  The Role of the Passive Structures in the Mobility and Stability of the Human Ankle Joint: A Literature Review , 2000, Foot & ankle international.

[18]  S B Murphy,et al.  Planning acetabular redirection osteotomies based on joint contact pressures. , 1999, Clinical orthopaedics and related research.

[19]  Thomas D Brown,et al.  Cartilage thickness in cadaveric ankles: measurement with double-contrast multi-detector row CT arthrography versus MR imaging. , 2004, Radiology.

[20]  T. Brown,et al.  Incongruity versus Instability in the Etiology of Posttraumatic Arthritis , 2004, Clinical orthopaedics and related research.

[21]  Gordon Clapworthy,et al.  Modern visualisation tools for research and education in biomechanics , 2004, Proceedings. Eighth International Conference on Information Visualisation, 2004. IV 2004..

[22]  Z. Jin,et al.  Contact mechanics analysis of metal-on-metal hip resurfacing prostheses , 2004, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[23]  S. Van Sint Jan,et al.  Modern visualisation tools for research and education in biomechanics , 2004 .

[24]  T D Brown,et al.  Contact stress aberrations following imprecise reduction of simple tibial plateau fractures , 1988, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.