A New Protection System for Islanding Detection in LV Distribution Systems

The growth of penetration of Distributed Generators (DGs) is increasing the risk of unwanted islanded operation in Low Voltage (LV) distribution systems. In this scenario, the existing anti-islanding protection systems, installed at the DG premises and based on classical voltage and frequency relays, are no longer effective, especially in the cases of islands characterized by a close match between generation and load. In this paper, a new protection system for islanding detection in LV distribution systems is proposed. The classical voltage and frequency relays in the DG interface protections are enriched with an innovative Smart Islanding Detector, which adopts a new passive islanding detection method. The aim is to keep the advantages of the classical relays while overcoming the problem of their limited sensitivity in detecting balanced islands. In the paper, to define the requirements of the anti-islanding protection system, the events causing the islanded operation of the LV distribution systems are firstly identified and classified. Then, referring to proposed protection system, its architecture and operation are described and, eventually, its performance is analyzed and validated by experimental laboratory tests, carried out with a hardware-in-the-loop technique.

[1]  Wil L. Kling,et al.  Future LV distribution network design and current practices in the Netherlands , 2011, 2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies.

[2]  Giuseppe Fusco,et al.  Islanding detection method based on a Thevenin-like model , 2015 .

[3]  Maurizio Delfanti,et al.  Coordination of interface protection systems for DG applications in MV distribution networks , 2013 .

[4]  R. Teodorescu,et al.  Overview of recent Grid Codes for PV power integration , 2012, 2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM).

[5]  V. Bufano,et al.  Innovative solutions to control unintentional islanding on LV network with high penetration of distributed generation , 2013 .

[6]  Giuseppe Fusco,et al.  A smart device for islanding detection in distribution system operation , 2015 .

[7]  R. Teodorescu,et al.  Overview of recent grid codes for wind power integration , 2010, 2010 12th International Conference on Optimization of Electrical and Electronic Equipment.

[8]  R. Turri,et al.  Risk of unintentional islanding in LV distribution networks with inverter-based DGs , 2013, 2013 48th International Universities' Power Engineering Conference (UPEC).

[9]  A. R. Di Fazio,et al.  Threshold setting of an innovative anti-islanding relay for LV distribution systems by real time simulations , 2014 .

[10]  Jaebok Lee,et al.  Transient false tripping characteristic analysis of ground fault circuit interrupter , 2004, 2004 International Conference on Power System Technology, 2004. PowerCon 2004..

[11]  Olimpo Anaya-Lara,et al.  Reducing unnecessary disconnection of renewable generation from the power system , 2007 .

[12]  D. V. Nicolae,et al.  LV self balancing distribution network reconfiguration for minimum losses , 2009, 2009 IEEE Bucharest PowerTech.

[13]  J. R. McDonald,et al.  UK distribution system protection issues , 2007 .

[14]  Alexandre Oudalov,et al.  Islanding detection in smart grids , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[15]  S. Chowdhury,et al.  Impacts of DG on the operation of auto-reclosing devices in a power network , 2011, 2011 IEEE Power and Energy Society General Meeting.

[16]  Wilsun Xu,et al.  False operation of vector surge relays , 2004, IEEE Transactions on Power Delivery.

[17]  D.V. Nicolae,et al.  Reconfiguration and Load Balancing in the LV and MV Distribution Networks for Optimal Performance , 2007, IEEE Transactions on Power Delivery.

[18]  M. Fotuhi-Firuzabad,et al.  Incorporating Service Quality Regulation in Distribution System Maintenance Strategy , 2011, IEEE Transactions on Power Delivery.

[19]  Miles A Redfern,et al.  Protection against loss of utility grid supply for a dispersed storage and generation unit , 1993 .