Three-leg inverter-based distribution static compensator topology for compensating unbalanced and non-linear loads

This study proposes a new three-leg voltage source inverter (VSI)-based distribution static compensator (DSTATCOM) topology to compensate unbalanced and non-linear loads in low-voltage three-phase four-wire distribution systems. The proposed topology uses a three-leg VSI with a single DC storage capacitor. This scheme has an additional small AC capacitor which is connected between negative DC bus to the system neutral. As the proposed topology uses a single DC-link capacitor, the DC voltage balancing issues associated with the popular split capacitor neutral clamped VSI topology is avoided. Moreover, the topology is able to compensate neutral current without using four-leg inverter topology. Analysis and modelling of the proposed topology is explained in detail. Simulation studies are carried out to verify the performance of the proposed scheme and results are presented. The performance of the new topology has been compared with conventional three-leg two level split capacitor VSI-based DSTATCOM topology. Results are also experimentally verified on a laboratory prototype of DSTATCOM.

[1]  A. Ghosh,et al.  Control Schemes for DC Capacitor Voltages Equalization in Diode-Clamped Multilevel Inverter-Based DSTATCOM , 2008, IEEE Transactions on Power Delivery.

[2]  A. Ghosh,et al.  Control Strategies for Load Compensation Using Instantaneous Symmetrical Component Theory Under Different Supply Voltages , 2008, IEEE Transactions on Power Delivery.

[3]  Mahesh Kumar Mishra,et al.  DC Capacitor Voltage Equalization in Neutral Clamped Inverters for DSTATCOM Application , 2010, IEEE Transactions on Industrial Electronics.

[4]  B. Singh,et al.  Reduced Rating VSC With a Zig-Zag Transformer for Current Compensation in a Three-Phase Four-Wire Distribution System , 2009, IEEE Transactions on Power Delivery.

[5]  Mahesh K. Mishra,et al.  Improved hysteresis current control of three-level inverter for distribution static compensator application , 2009 .

[6]  Bhim Singh,et al.  Implementation of four-leg distribution static compensator , 2014 .

[7]  Arindam Ghosh,et al.  Inverter topologies for DSTATCOM applications—a simulation study , 2005 .

[8]  Chandan Kumar,et al.  An Improved Hybrid DSTATCOM Topology to Compensate Reactive and Nonlinear Loads , 2014, IEEE Transactions on Industrial Electronics.

[9]  Bidyadhar Subudhi,et al.  Model predictive-based shunt active power filter with a new reference current estimation strategy , 2015 .

[10]  A. Joshi,et al.  A Novel Method of Load Compensation Under Unbalanced and Distorted Voltages , 2007, IEEE Transactions on Power Delivery.

[11]  Leonardo Bruno Garcia Campanhol,et al.  Application of shunt active power filter for harmonic reduction and reactive power compensation in three-phase four-wire systems , 2014 .

[12]  Pramod Agarwal,et al.  Neutral current compensation in three-phase, four-wire systems: A review , 2012 .

[13]  Taehyung Kim,et al.  Shunt active filter based on three-level inverter for three-phase four-wire systems , 2009 .

[14]  Bhim Singh,et al.  Digital signal processor implementation and performance evaluation of split capacitor, four-leg and three H-bridge-based three-phase four-wire shunt active filters , 2011 .

[15]  An Luo,et al.  Injection-type hybrid active power filter in high-power grid with background harmonic voltage , 2011 .

[16]  Malabika Basu,et al.  Real-time control of shunt active power filter under distorted grid voltage and unbalanced load condition using self-tuning filter , 2014 .

[17]  M. K. Mishra,et al.  A DSTATCOM Topology With Reduced DC-Link Voltage Rating for Load Compensation With Nonstiff Source , 2012, IEEE Transactions on Power Electronics.

[18]  T. M. Gruzs A survey of neutral currents in three-phase computer power systems , 1989 .

[19]  Kamal Al-Haddad,et al.  Comprehensive Study of DSTATCOM Configurations , 2014, IEEE Transactions on Industrial Informatics.

[20]  Malabika Basu,et al.  Harmonic power compensation capacity of shunt active power filter and its relationship with design parameters , 2014 .

[21]  Mahesh K. Mishra,et al.  An Investigation on Design and Switching Dynamics of a Voltage Source Inverter to Compensate Unbalanced and Nonlinear Loads , 2009, IEEE Transactions on Industrial Electronics.

[22]  Arindam Ghosh,et al.  Load compensating DSTATCOM in weak AC systems , 2003 .

[23]  Arindam Ghosh,et al.  A new approach to load balancing and power factor correction in power distribution system , 2000 .

[24]  Avik Bhattacharya,et al.  Parallel-Connected Shunt Hybrid Active Power Filters Operating at Different Switching Frequencies for Improved Performance , 2012, IEEE Transactions on Industrial Electronics.

[25]  P. N. Tekwani,et al.  Analysis, design and digital implementation of a shunt active power filter with different schemes of reference current generation , 2014 .

[26]  Hurng-Liahng Jou,et al.  Novel Circuit Topology for Three-Phase Active Power Filter , 2007, IEEE Transactions on Power Delivery.

[27]  B. Singh,et al.  A T-Connected Transformer and Three-leg VSC Based DSTATCOM for Power Quality Improvement , 2008, IEEE Transactions on Power Electronics.

[28]  Boon-Teck Ooi,et al.  Regulating and equalizing DC capacitance voltages in multilevel STATCOM , 1997 .

[29]  P. Salmeron,et al.  Analysis and design of different control strategies of hybrid active power filter based on the state model , 2012 .

[30]  An Luo,et al.  Distribution static compensator based on an improved direct power control strategy , 2014 .

[31]  Qijuan Chen,et al.  Shunt active power filter with enhanced dynamic performance using novel control strategy , 2014 .

[32]  Chi-Seng Lam,et al.  Hysteresis current control of hybrid active power filters , 2012 .

[33]  Mahmadasraf A. Mulla,et al.  Compensation of three-phase diode rectifier with capacitive filter working under unbalanced supply conditions using series hybrid active power filter , 2014 .