Assessing sleep architecture and continuity measures through the analysis of heart rate and wrist movement recordings in healthy subjects: comparison with results based on polysomnography.

OBJECTIVE The objective of the study was to evaluate the reliability of a new methodology for assessing sleep architecture descriptors based on heart rate and body movement recordings. METHODS Twelve healthy male and female subjects between 18 and 40 years of age, without sleep disorders and not taking any drug or medication that could affect sleep, were recorded continuously during five consecutive nights. Together with the standard polysomnography, heart rate was recorded with a Holter and wrist movements by actimetry. Of the 60 recorded nights, 48 artifact-free nights were analyzed by two independent and well-trained visual scorers according to the rules of the American Academy of Sleep Medicine. Sleep stages were assigned to every 30-s epoch. In parallel, the same nights were analyzed by the new methodology using only heart rate and actimetry data, allowing a 1-s epoch sleep stage classification. Sleep architecture was measured for 48 nights, independently for the two manual scorings and the automatic analysis. RESULTS Over 42 nights, the intra-class correlation coefficient, used to assess the consistency or reproducibility of quantitative measurements made by different observers, was classified as excellent when all 12 descriptors were combined. Analyses of the individual descriptors showed excellent interclass correlation for eight and good for four of the 12. CONCLUSION The automatic analysis of heart rate and body movement during sleep allows for the evaluation of sleep architecture and continuity that is equivalent to those obtained by manual scoring of polysomnography. The technique used here is simple and robust to allow for home sleep monitoring.

[1]  A Värri,et al.  A simple format for exchange of digitized polygraphic recordings. , 1992, Electroencephalography and clinical neurophysiology.

[2]  Alfred L. Loomis,et al.  Electrical potentials of the human brain , 1936 .

[3]  R. Rosenberg,et al.  The American Academy of Sleep Medicine inter-scorer reliability program: sleep stage scoring. , 2013, Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine.

[4]  Atul Malhotra,et al.  Sleep staging based on autonomic signals: a multi-center validation study. , 2011, Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine.

[5]  S. Nevsimalova,et al.  Spectral analysis of heart rate variability in sleep. , 2005, Physiological Research.

[6]  A. Rechtschaffen A manual of Standardized Terminology , 1968 .

[7]  Chris Berka,et al.  Retrospective cross-validation of automated sleep staging using electroocular recording in patients with and without sleep disordered breathing , 2012, International archives of medicine.

[8]  R. Strecker,et al.  Recent Developments in Home Sleep-Monitoring Devices , 2012, ISRN neurology.

[9]  Alain Muzet,et al.  Body movements during sleep as a predictor of stage change , 1972 .

[10]  Frederic Roche,et al.  Cardiac variability and heart-rate increment as a marker of sleep fragmentation in patients with a sleep disorder: a preliminary study. , 2007, Sleep.

[11]  D. Rapoport,et al.  Interobserver agreement among sleep scorers from different centers in a large dataset. , 2000, Sleep.

[12]  John R. Shambroom,et al.  Validation of an automated wireless system to monitor sleep in healthy adults , 2012, Journal of sleep research.

[13]  K. McGraw,et al.  Forming inferences about some intraclass correlation coefficients. , 1996 .

[14]  A. Chesson,et al.  The American Academy of Sleep Medicine (AASM) Manual for the Scoring of Sleep and Associated Events: Rules, Terminology and Technical Specifications , 2007 .

[15]  L. Meltzer,et al.  Direct comparison of two new actigraphs and polysomnography in children and adolescents. , 2012, Sleep.

[16]  J. Carrier,et al.  Wake detection capacity of actigraphy during sleep. , 2007, Sleep.

[17]  Thomas Penzel,et al.  Inter-scorer reliability between sleep centers can teach us what to improve in the scoring rules. , 2013, Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine.

[18]  D. Cicchetti Guidelines, Criteria, and Rules of Thumb for Evaluating Normed and Standardized Assessment Instruments in Psychology. , 1994 .

[19]  W. Dement,et al.  Cyclic variations in EEG during sleep and their relation to eye movements, body motility, and dreaming. , 1957, Electroencephalography and clinical neurophysiology.

[20]  C. Pollak,et al.  The role of actigraphy in the study of sleep and circadian rhythms. , 2003, Sleep.

[21]  Bronwyn Stevens,et al.  The 2007 AASM recommendations for EEG electrode placement in polysomnography: impact on sleep and cortical arousal scoring. , 2011, Sleep.

[22]  Meng Xiao,et al.  Sleep stages classification based on heart rate variability and random forest , 2013, Biomed. Signal Process. Control..

[23]  P. Anderer,et al.  Interrater reliability for sleep scoring according to the Rechtschaffen & Kales and the new AASM standard , 2009, Journal of sleep research.

[24]  L. Johnson,et al.  Computer extraction of an ultradian cycle in sleep from manually scored sleep stages. , 1973, International journal of chronobiology.

[25]  A. Rechtschaffen,et al.  A manual of standardized terminology, technique and scoring system for sleep stages of human subjects , 1968 .

[26]  R. Burr,et al.  Interpretation of normalized spectral heart rate variability indices in sleep research: a critical review. , 2007, Sleep.

[27]  Luca Citi,et al.  Instantaneous monitoring of sleep fragmentation by point process heart rate variability and respiratory dynamics , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[28]  M. Dumont,et al.  Interdependency between heart rate variability and sleep EEG: linear/non-linear? , 2004, Clinical Neurophysiology.

[29]  M. Bresler,et al.  Differentiating between light and deep sleep stages using an ambulatory device based on peripheral arterial tonometry , 2008, Physiological measurement.

[30]  W. Baust,et al.  The regulation of heart rate during sleep. , 1969, Experimental brain research.

[31]  A. Sadeh The role and validity of actigraphy in sleep medicine: an update. , 2011, Sleep medicine reviews.

[32]  Sonia Ancoli-Israel,et al.  Comparison of sleep parameters from actigraphy and polysomnography in older women: the SOF study. , 2008, Sleep.

[33]  M. Dumont,et al.  A study of the dynamic interactions between sleep EEG and heart rate variability in healthy young men , 2003, Clinical Neurophysiology.

[34]  Characteristics of rapid eye movement production during REM sleep in man: organization and rhythmicity. , 1983, Electroencephalography and clinical neurophysiology.

[35]  N. Butkov,et al.  Digital analysis and technical specifications. , 2007, Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine.

[36]  Alain Muzet,et al.  Sleep Processes Exert a Predominant Influence on the 24-h Profile of Heart Rate Variability , 2002, Journal of biological rhythms.

[37]  S. Cerutti,et al.  Sleep staging classification based on HRV: Time-variant analysis , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[38]  A. Muzet,et al.  Sleep stage scoring using the neural network model: comparison between visual and automatic analysis in normal subjects and patients. , 1996, Sleep.

[39]  E. Wolpert A Manual of Standardized Terminology, Techniques and Scoring System for Sleep Stages of Human Subjects. , 1969 .