A complete distortion correction for MR images: I. Gradient warp correction

MR images are known to be distorted because of both gradient nonlinearity and imperfections in the B0 field, the latter caused either by an imperfect shim or sample-induced distortions. This paper describes in detail a method for correcting the gradient warp distortion, based on a direct field mapping using a custom-built phantom with three orthogonal grids of fluid-filled rods. The key advance of the current work over previous contributions is the large volume of the mapping phantom and the large distortions (>25 mm) corrected, making the method suitable for use with large field of view, extra-cranial images. Experimental measurements on the Siemens AS25 gradient set, as installed on a Siemens Vision scanner, are compared with a theoretical description of the gradient set, based on the manufacturer's spherical harmonic coefficients. It was found that over a volume of 320x200x340 mm3 distortions can be successfully mapped to within the voxel resolution of the raw imaging data, whilst outside this volume, correction is still good but some systematic errors are present. The phenomenon of through-plane distortion (also known as 'slice warp') is examined in detail, and the perturbation it causes to the measurements is quantified and corrected. At the very edges of the region of support provided by the phantom, through-plane distortion is extreme and only partially corrected by the present method. Solutions to this problem are discussed. Both phantom and patient data demonstrate the efficacy of the gradient warp correction.

[1]  S. Riederer,et al.  Correction for gradient nonlinearity in continuously moving table MR imaging , 2004, Magnetic resonance in medicine.

[2]  Steve Webb,et al.  Radiotherapy treatment planning of prostate cancer using magnetic resonance imaging alone. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[3]  Martin O Leach,et al.  A complete distortion correction for MR images: II. Rectification of static-field inhomogeneities by similarity-based profile mapping , 2005, Physics in medicine and biology.

[4]  M A Moerland,et al.  Analysis and correction of geometric distortions in 1.5 T magnetic resonance images for use in radiotherapy treatment planning. , 1995, Physics in medicine and biology.

[5]  A. Jones Diagnostic imaging as a measuring device for stereotactic neurosurgery , 1993, Physiological measurement.

[6]  W. J. Lorenz,et al.  Correction of spatial distortion in magnetic resonance angiography for radiosurgical treatment planning of cerebral arteriovenous malformations. , 1992, Magnetic resonance imaging.

[7]  R. Pötter,et al.  Effect of distortions and asymmetry in MR images on radiotherapeutic treatment planning , 2000, International journal of cancer.

[8]  D P Dearnaley,et al.  Radiotherapy planning of the pelvis using distortion corrected MR images: the removal of system distortions. , 2000, Physics in medicine and biology.

[9]  Huawei Zhao,et al.  Use of spherical harmonic deconvolution methods to compensate for nonlinear gradient effects on MRI images , 2004, Magnetic resonance in medicine.

[10]  G. Arfken Mathematical Methods for Physicists , 1967 .

[11]  Gary H. Glover,et al.  MR susceptibility misregistration correction , 1993, IEEE Trans. Medical Imaging.

[12]  M. O’Donnell,et al.  NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities. , 1985, Medical physics.

[13]  G. Glover,et al.  Mr geometric distortion correction for improved frame‐based stereotaxic target localization accuracy , 1995, Magnetic resonance in medicine.

[14]  Richard Pötter,et al.  Aspects of MR Image Distortions in Radiotherapy Treatment Planning , 2001, Strahlentherapie und Onkologie.

[15]  J. Michael Fitzpatrick,et al.  Geometrical image transformation to compensate for MRI distortions , 1990, Medical Imaging: Image Processing.

[16]  L Walton,et al.  Stereotactic localization with magnetic resonance imaging: a phantom study to compare the accuracy obtained using two-dimensional and three-dimensional data acquisitions. , 1997, Neurosurgery.

[17]  G. Bednarz,et al.  Evaluation of the spatial accuracy of magnetic resonance imaging-based stereotactic target localization for gamma knife radiosurgery of functional disorders. , 1999, Neurosurgery.

[18]  D. Jeanmonod,et al.  Accuracy of MRI-guided stereotactic thalamic functional neurosurgery , 1999, Neuroradiology.

[19]  Deming Wang,et al.  A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging. , 2004, Magnetic resonance imaging.

[20]  M A Moerland,et al.  Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imaging. , 1992, Magnetic resonance imaging.