Signal dropout correction-based ultrasound segmentation for diastolic mitral valve modeling

Abstract. Three-dimensional ultrasound segmentation of mitral valve (MV) at diastole is helpful for duplicating geometry and pathology in a patient-specific dynamic phantom. The major challenge is the signal dropout at leaflet regions in transesophageal echocardiography image data. Conventional segmentation approaches suffer from missing sonographic data leading to inaccurate MV modeling at leaflet regions. This paper proposes a signal dropout correction-based ultrasound segmentation method for diastolic MV modeling. The proposed method combines signal dropout correction, image fusion, continuous max-flow segmentation, and active contour segmentation techniques. The signal dropout correction approach is developed to recover the missing segmentation information. Once the signal dropout regions of TEE image data are recovered, the MV model can be accurately duplicated. Compared with other methods in current literature, the proposed algorithm exhibits lower computational cost. The experimental results show that the proposed algorithm gives competitive results for diastolic MV modeling compared with conventional segmentation algorithms, evaluated in terms of accuracy and efficiency.

[1]  Terry M. Peters,et al.  Dynamic heart phantom with functional mitral and aortic valves , 2015, Medical Imaging.

[2]  Paul A. Yushkevich,et al.  Fully automatic segmentation of the mitral leaflets in 3D transesophageal echocardiographic images using multi-atlas joint label fusion and deformable medial modeling , 2014, Medical Image Anal..

[3]  Nicholas Dwork,et al.  Formulation of image fusion as a constrained least squares optimization problem , 2017, Journal of medical imaging.

[4]  Michael I Miga,et al.  Evaluation of model-based deformation correction in image-guided liver surgery via tracked intraoperative ultrasound , 2016, Journal of medical imaging.

[5]  Michael I Miga,et al.  Model-based correction of tissue compression for tracked ultrasound in soft tissue image-guided surgery. , 2014, Ultrasound in medicine & biology.

[6]  Terry M. Peters,et al.  Real-time segmentation in 4D ultrasound with continuous max-flow , 2012, Medical Imaging.

[7]  Eigil Samset,et al.  Semiautomated biventricular segmentation in three-dimensional echocardiography by coupled deformable surfaces , 2017, Journal of medical imaging.

[8]  Terry M. Peters,et al.  Hierarchical max-flow segmentation framework for multi-atlas segmentation with Kohonen self-organizing map based Gaussian mixture modeling , 2016, Medical Image Anal..

[9]  Eigil Samset,et al.  Parametric ultrasound and fluoroscopy image fusion for guidance of left ventricle lead placement in cardiac resynchronization therapy , 2015, Journal of medical imaging.

[10]  Maryellen L. Giger,et al.  Segmentation of breast masses on dedicated breast computed tomography and three-dimensional breast ultrasound images , 2014, Journal of medical imaging.

[11]  Robert D. Howe,et al.  Patient-Specific Mitral Leaflet Segmentation from 4D Ultrasound , 2011, MICCAI.

[12]  Johan G Bosch,et al.  Fully automatic detection of salient features in 3-d transesophageal images. , 2014, Ultrasound in medicine & biology.

[13]  Robert D. Howe,et al.  Mitral Annulus Segmentation From 3D Ultrasound Using Graph Cuts , 2010, IEEE Transactions on Medical Imaging.

[14]  Xue-Cheng Tai,et al.  A Convex and Exact Approach to Discrete Constrained TV-L1 Image Approximation , 2011 .

[15]  Mila Nikolova,et al.  Algorithms for Finding Global Minimizers of Image Segmentation and Denoising Models , 2006, SIAM J. Appl. Math..

[16]  Henry Leung,et al.  Performance analysis of statistical optimal data fusion algorithms , 2014, Inf. Sci..

[17]  Martin Rajchl,et al.  Optimization-based interactive segmentation interface for multiregion problems , 2016, Journal of medical imaging.

[18]  J. Gardin,et al.  Burden of valvular heart diseases: a population-based study , 2006, The Lancet.

[19]  Mauro Pepi,et al.  Semi-automated segmentation and quantification of mitral annulus and leaflets from transesophageal 3-D echocardiographic images. , 2015, Ultrasound in medicine & biology.

[20]  Terry M. Peters,et al.  Patient-specific indirectly 3D printed mitral valves for pre-operative surgical modelling , 2017, Medical Imaging.

[21]  Nassir Navab,et al.  Patient-Specific Modeling and Quantification of the Aortic and Mitral Valves From 4-D Cardiac CT and TEE , 2010, IEEE Transactions on Medical Imaging.

[22]  Xue-Cheng Tai,et al.  A Continuous Max-Flow Approach to Potts Model , 2010, ECCV.

[23]  Tony F. Chan,et al.  Active contours without edges , 2001, IEEE Trans. Image Process..