Correction of the Respiratory Motion of the Heart by Tracking of the Center of Mass of Thresholded Projections: A Simulation Study Using the Dynamic MCAT Phantom.

During normal breathing, heart motion is about 15 mm along the body axis in humans. We propose a method to track and to correct this motion after a list-mode acquisition which involves the recording of a signal proportional to respiratory volume. We use the dynamic MCAT (DMCAT) chest phantom to simulate 24 temporal frames regularly spaced during the respiratory cycle, for 60 projection angles over 360/spl deg/. A 15-mm respiratory translation motion is simulated for the heart, liver and spleen. Thresholding of projections is used to reduce the influence of static activity on calculation of the axial center-of-mass (aCOM). Variation in the impact of attenuation as a function of projections and noise in the low-count projections rebinned from list-mode acquisitions is seen to limit ones ability to track respiratory motion using the aCOM. By including the recording of a signal proportional to the relative respiratory volume with the list-mode acquisition counts from different respiratory cycles can be combined to produce projections with common respiratory volumes. We have determined that the aCOMs determined from summing these common-volume based projections over the anterior to left-anterior oblique projection angles can be used to track respiratory motion as a function of the volume signal. Using this information on the variation of the aCOM as a function of the volume signal, the entire list-mode acquisition can then be rebinned into a projection set which is corrected for respiratory motion. After motion tracking, the mean absolute difference between the true motion curve and the aCOM curve is 0.10 cm for noisy studies. After correction no heart motion is visible on a cine display of projections. The polar map of myocardial MIBI uptake after motion correction is closer to that obtained when no respiratory motion is present than without correction.

[1]  G. J. Klein,et al.  Real-time system for respiratory-cardiac gating in positron tomography , 1997 .

[2]  Lee-Tzuu Chang,et al.  A Method for Attenuation Correction in Radionuclide Computed Tomography , 1978, IEEE Transactions on Nuclear Science.

[3]  Benjamin M. W. Tsui,et al.  Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms , 1999 .

[4]  Respiratory gating in magnetic resonance imaging: improved image quality over non-gated images for equal scan time. , 1991, Clinical imaging.

[5]  T Kumazaki,et al.  Development of respiratory gated myocardial SPECT system , 1999, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[6]  Michael A. King,et al.  A study of possible causes of artifactual decreases in the left ventricular apex with SPECT cardiac perfusion imaging , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[7]  B E Oppenheim,et al.  A method using a digital computer for reducing respiratory artifact on liver scans made with a camera. , 1971, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  J. Petasnick,et al.  Quantification of the respiratory motion artifact in radioisotope scanning with the rectilinear focused collimator scanner and the gamma scintillation camera. , 1966, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  K. Murata,et al.  Accurate contiguous sections without breath-holding on chest CT: value of respiratory gating and ultrafast CT. , 1994, AJR. American journal of roentgenology.

[10]  N J Pelc,et al.  Simultaneous temporal resolution of cardiac and respiratory motion in MR imaging. , 1995, Radiology.

[11]  D. Berman,et al.  Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[12]  M. King,et al.  A mathematical model of motion of the heart for use in generating source and attenuation maps for simulating emission imaging. , 1999, Medical physics.

[13]  Jerold Warren Wallis,et al.  An optimal rotator for iterative reconstruction , 1997, IEEE Transactions on Medical Imaging.

[14]  R C Grimm,et al.  Respiratory kinematics of the upper abdominal organs: A quantitative study , 1992, Magnetic resonance in medicine.

[15]  P Schmidlin,et al.  Development and comparison of computer methods for organ motion correction in scintigraphy. , 1975, Physics in medicine and biology.

[16]  P B Hoffer,et al.  Motion corrected hepatic scintigraphy: an objective clinical evaluation. , 1978, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  J. Cacioppo,et al.  Impedance pneumography: noise as signal in impedance cardiography. , 1999, Psychophysiology.

[18]  H. Hricak,et al.  Magnetic resonance imaging with respiratory gating: techniques and advantages. , 1984, AJR. American journal of roentgenology.

[19]  P B Hoffer,et al.  A simple device for reducing motion artifacts in gamma camera images. , 1972, Radiology.

[20]  S. Riederer,et al.  Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary Imaging , 1995, Magnetic resonance in medicine.

[21]  G. Zeng,et al.  Three-dimensional SPECT reconstruction of combined cone-beam and fan-beam data , 1992 .

[22]  I. G. Zubal,et al.  Dual Gated Nuclear Cardiac Images , 1984, IEEE Transactions on Nuclear Science.

[23]  D. Berman,et al.  Detection and correction of patient motion in dynamic and static myocardial SPECT using a multi-detector camera. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.