Design and Characterization of a Sampling System Based on $\Sigma$–$\Delta$ Analog-to-Digital Converters for Electrical Metrology

This paper describes a sampling system designed using a commercial sigma-delta analog-to-digital converter (Sigma-Delta ADC). In addition to characterization measurements using a conventional high-quality signal generator, a Josephson waveform synthesizer that provides ultimately noise- and drift-free voltages was used. To evaluate the suitability of this sampling system as part of a transfer power standard, additional comparisons of the root-mean-square (RMS) values measured were performed against a thermal converter and the primary power sampling standard at the Physikalisch-Technische Bundesanstalt, Braunschweig, Germany. Initial analysis of the measurement data shows an effective resolution in the range of 18-19 bits at an equivalent sampling rate of 64 kHz. The integral nonlinearity error of the system was measured to be within plusmn7 muV/V or one least significant bit at this resolution.

[1]  Gabor C. Temes,et al.  Understanding Delta-Sigma Data Converters , 2004 .

[2]  Enrico Mohns An audio frequency multiplier with planar thermal converters for power measurements , 2008, 2008 Conference on Precision Electromagnetic Measurements Digest.

[3]  Torsten Funck,et al.  Synthesis of precision waveforms using a SINIS Josephson junction array , 2005, IEEE Transactions on Instrumentation and Measurement.

[4]  Harald Moser,et al.  Primary AC Power Standard Based on Programmable Josephson Junction Arrays , 2007, IEEE Transactions on Instrumentation and Measurement.

[5]  W.G.K. Ihlenfeld,et al.  A new sampling transfer standard of highest accuracy for AC quantities , 2008, 2008 Conference on Precision Electromagnetic Measurements Digest.

[6]  E. Mohns,et al.  A sampling system based on Σ—Δ analog-to-digital converters , 2008, 2008 Conference on Precision Electromagnetic Measurements Digest.

[7]  Ralf Behr,et al.  The Josephson effect based primary ac power standard at PTB: progress report , 2008, 2008 Conference on Precision Electromagnetic Measurements Digest.

[8]  E. Mohns,et al.  Characterization of a High-Resolution Analog-to-Digital Converter with an Ac Josephson Voltage Source , 2004, 2004 Conference on Precision Electromagnetic Measurements.

[9]  Thomas J. Witt,et al.  Using the Allan variance and power spectral density to characterize dc nanovoltmeters , 2000, Conference on Precision Electromagnetic Measurements. Conference Digest. CPEM 2000 (Cat. No.00CH37031).

[10]  J. Kohlmann,et al.  Improved 10 V SINIS Series Arrays for Applications in AC Voltage Metrology , 2007, IEEE Transactions on Applied Superconductivity.

[11]  Pasquale Daponte,et al.  Modeling and characterization of sigma-delta analog-to-digital converters , 1998, IMTC/98 Conference Proceedings. IEEE Instrumentation and Measurement Technology Conference. Where Instrumentation is Going (Cat. No.98CH36222).

[12]  J. Kohlmann,et al.  Synthesis of precision AC waveforms using a SINIS Josephson junction array , 2002, Conference Digest Conference on Precision Electromagnetic Measurements.

[13]  Harald Moser,et al.  A new scheme for generating and measuring active, reactive, and apparent power at power frequencies with uncertainties of 2.5×10 -6 , 1998, IEEE Trans. Instrum. Meas..

[14]  G. Rietveld,et al.  Calibrating a sampling voltmeter using a binary Josephson system , 2008, 2008 Conference on Precision Electromagnetic Measurements Digest.

[15]  Ralf Behr,et al.  Characterization of a high-resolution analog-to-digital converter with a Josephson AC voltage source , 2005, IEEE Transactions on Instrumentation and Measurement.