Automated resolution of dichlorvos and methylparaoxon pesticide mixtures employing a Flow Injection system with an inhibition electronic tongue.

An amperometric biosensor array has been developed to resolve pesticide mixtures of dichlorvos and methylparaoxon. The biosensor array has been used in a Flow Injection system, in order to operate automatically the inhibition procedure. The sensors used were three screen-printed amperometric biosensors that incorporated three different acetylcholinesterase enzymes: the wild type from Electric eel and two different genetically modified enzymes, B1 and B394 mutants, from Drosophila melanogaster. The inhibition response triplet was modelled using an Artificial Neural Network which was trained with mixture solutions that contain dichlorvos from 10(-4) to 0.1 microM and methylparaoxon from 0.001 to 2.5 microM. This system can be considered an inhibition electronic tongue.

[1]  Jean-Louis Marty,et al.  Biosensors based on highly sensitive acetylcholinesterases for enhanced carbamate insecticides detection , 2006 .

[2]  J. Marty,et al.  Improved multianalyte detection of organophosphates and carbamates with disposable multielectrode biosensors using recombinant mutants of Drosophila acetylcholinesterase and artificial neural networks. , 2000, Biosensors & bioelectronics.

[3]  D. Ivnitski,et al.  A quantitative determination of organophosphate pesticides in organic solvents , 2000 .

[4]  A. L. Hart,et al.  The response of screen-printed enzyme electrodes containing cholinesterases to organo-phosphates in solution and from commercial formulations , 1997 .

[5]  A. Townshend,et al.  Flow-injection determination of paraoxon by inhibition of immobilized acetylcholinesterase , 1990 .

[6]  D. Barceló,et al.  Detection of endocrine-disrupting pesticides by enzyme-linked immunosorbent assay (ELISA): application to atrazine , 1997 .

[7]  Rolf D. Schmid,et al.  A disposable multielectrode biosensor for rapid simultaneous detection of the insecticides paraoxon and carbofuran at high resolution , 1999 .

[8]  Jean-Louis Marty,et al.  Comparative investigation between acetylcholinesterase obtained from commercial sources and genetically modified Drosophila melanogaster: application in amperometric biosensors for methamidophos pesticide detection. , 2004, Biosensors & bioelectronics.

[9]  M. Valle,et al.  Automated SIA System Using an Array of Potentiometric Sensors for Determining Alkaline-Earth Ions in Water , 2007 .

[10]  Ingemar Lundström,et al.  2nd Workshop of the Second Network on Artificial Olfactory Sensing (NOSE II) , 2004 .

[11]  Gabriela Valdés-Ramírez,et al.  Sensitive amperometric biosensor for dichlorovos quantification: Application to detection of residues on apple skin. , 2008, Talanta.

[12]  Alisa Rudnitskaya,et al.  Cross-sensitivity evaluation of chemical sensors for electronic tongue: determination of heavy metal ions , 1997 .

[13]  K. Courtney,et al.  A new and rapid colorimetric determination of acetylcholinesterase activity. , 1961, Biochemical pharmacology.

[14]  Marinella Sabina Turdean,et al.  Synergetic effect of organic solvents and paraoxon on the immobilized acetylcholinesterase , 2008 .

[15]  Jean-Louis Marty,et al.  Insecticide identification using a flow injection analysis system with biosensors based on various cholinesterases , 2005 .

[16]  Jean-Louis Marty,et al.  Screen-printed electrode based on AChE for the detection of pesticides in presence of organic solvents. , 2002, Talanta.

[17]  C. Bessant,et al.  Multivariate Data Analysis in Electroanalytical Chemistry , 2002 .

[18]  Jean-Louis Marty,et al.  Twenty years research in cholinesterase biosensors: from basic research to practical applications. , 2006, Biomolecular engineering.

[19]  Jean-Louis Marty,et al.  Electronic Tongue Using an Enzyme Inhibition Biosensor Array for the Resolution of Pesticide Mixtures , 2008 .

[20]  S. Massry,et al.  Altered acetylcholine metabolism of brain in uremia: role of secondary hyperparathyroidism. , 2008, Journal of renal nutrition : the official journal of the Council on Renal Nutrition of the National Kidney Foundation.

[21]  Salvador Alegret,et al.  Potentiometric bioelectronic tongue for the analysis of urea and alkaline ions in clinical samples. , 2007, Biosensors & bioelectronics.

[22]  S. Higson,et al.  Sonochemically fabricated acetylcholinesterase micro-electrode arrays within a flow injection analyser for the determination of organophosphate pesticides. , 2005, Biosensors & bioelectronics.

[23]  Y. Ni,et al.  Simultaneous voltammetric determination of four carbamate pesticides with the use of chemometrics , 2005 .

[24]  M. Kujawa FAO Plant Production and Protection Paper, Pesticide Residues in Food; Evaluations 1979, 560 Seiten. Food and Agriculture Organization of the United Nations, Rome 1980. , 1982 .

[25]  Serge Kokot,et al.  Simultaneous Determination of Three Organophosphorus Pesticides by Differential Pulse Stripping Voltammetry and Chemometrics , 2004 .

[26]  Jean-Louis Marty,et al.  Enzyme immobilization procedures on screen-printed electrodes used for the detection of anticholinesterase pesticides Comparative study , 2004 .

[27]  Alisa Rudnitskaya,et al.  A flow injection system based on chalcogenide glass sensors for the determination of heavy metals , 2000 .

[28]  Sun Gang,et al.  Application of artificial neural networks coupled with an orthogonal design and optimization algorithms to multifactor optimization of a new FIA system for the determination of uranium(VI) in ore samples , 2000 .