Partial-Discharge Characteristics of Free Spherical Conducting Particles Under AC Condition in Transformer Oils

One of the major problems in the liquid insulation is the particle contamination, which can seriously degrade the withstand voltage of the insulation. The movement of conducting particles under operation voltage can generate incipient discharges that can lead to the complete failure of the insulation system during operation. The partial-discharge characteristics of the free spherical conducting particle in the quasiuniform electric field were studied in this paper in order to better explain the partial-discharge (PD) measurement signals for particle movement and implications for insulation diagnostics in power transformers. The phase-resolved partial-discharge (PRPD) pattern was measured and the PD inception voltage, PD charges, and PD frequency were studied under different applied voltages. The influence of oil aging degree to particle PD characteristics was also studied in this paper. It is observed that the PD pattern is different in a different particle motion stage and the number of particles has a significant influence on PD frequency and a slight influence on PD pattern. The particle is inactive in severely aged transformer oil. The PD charges and PD frequency (pulses number per half ac cycle) reduce with the aging degree of the oil sample.

[1]  Lucian Dascalescu,et al.  Modeling of Conductive Particle Behavior in Insulating Fluids Affected by , 1998 .

[2]  Alan Emsley,et al.  Degradation of cellulosic insulation in power transformers. Part 3: effects of oxygen and water on ageing in oil , 2000 .

[3]  E. Gockenbach,et al.  Influence of carbon particles on the breakdown and partial discharge inception voltage of aged mineral based transformer oil , 1996 .

[4]  Massimo Pompili,et al.  Phase relationship of PD pulses in dielectric liquids under ac conditions , 2000 .

[5]  R. Tobazeon,et al.  Behaviour of free conducting particles and their role on breakdown in oils under AC and DC voltages , 1992 .

[6]  M. Ali,et al.  Degradation of cellulosic insulation in power transformers. Part 2: formation of furan products in insulating oil , 2000 .

[7]  Lucian Dascalescu,et al.  Modelling of conductive particle behaviour in insulating fluids affected by DC electric fields , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[8]  Hossein Borsi,et al.  Influence of carbon particles on the breakdown voltage of transformer oil , 1996, ICDL'96. 12th International Conference on Conduction and Breakdown in Dielectric Liquids.

[9]  A. Cavallini,et al.  PD inference for the early detection of electrical treeing in insulation systems , 2004, IEEE Transactions on Dielectrics and Electrical Insulation.

[10]  Martin D. Judd,et al.  Partial discharge study in transformer oil due to particle movement under DC voltage using the UHF technique , 2008 .

[11]  S. Birlasekaran The measurement of charge on single particles in transformer oil , 1991 .

[12]  A. A. A-Rahim,et al.  Dynamic analysis of motion of spherical metallic particles in non-uniform electric field , 2002 .

[13]  S. Birlasekaran,et al.  The movement of a conducting particle in transformer oil in AC fields , 1993 .

[14]  Kamal Miners,et al.  Particles and Moisture Effect on Dielectric Strength of Transformer Oil Using VDE Electrodes , 1982, IEEE Transactions on Power Apparatus and Systems.

[15]  P. Purkait,et al.  Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformers , 2004, IEEE Transactions on Dielectrics and Electrical Insulation.

[16]  M. Pompili,et al.  PD pulse burst characteristics of transformer oils , 2006, IEEE Transactions on Power Delivery.

[17]  M. Salama,et al.  SVM classification of contaminating particles in liquid dielectrics using higher order statistics of electrical and acoustic PD measurements , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[18]  R. Tobazeon,et al.  Particle-initiated breakdown in a quasi-uniform field in transformer oil , 1995, IEEE Transactions on Dielectrics and Electrical Insulation.

[19]  R. Sarathi,et al.  Investigation of partial discharge activity of conducting particles in liquid nitrogen under DC voltages using uhf technique , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[20]  M. M. Morcos,et al.  Dynamics of metallic particle contaminants in GIS with dielectric-coated electrodes , 2000 .

[21]  M. Pompili,et al.  Partial discharge pulse sequence patterns and cavity development times in transformer oils under AC conditions , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.

[22]  A. Cavallini,et al.  A new methodology for the identification of PD in electrical apparatus: properties and applications , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.