Covalent surface chemical modification of electrodes for cardiac pacing applications.

We report the covalent surface modification of active-fixation pacemaker electrodes with butanethiol or dodecanethiol self-assembled monolayers (SAMs) using a platinum or gold metal-thiolate bond (i.e., changing the chemical identity of the exposed metal electrode from metal to organic) in such fashion that (a) the surface is organic in functionality with lipophilic physicochemical characteristics, (b) a possible degradation product is gold (I)-alkanethiolate with putative anti-inflammatory actions, and (c) current density/electric field strength is increased. Superior acute and chronic pacing performance with dodecanethiol-modified, gold-coated, platinum-iridium alloy pacemaker electrodes was observed with inferential evidence of reduced inflammation and scar. This approach may have applicability in other areas of bioelectrodes with practical applications in clinical cardiology, surgery, neuroscience, and subcutaneous sensors.

[1]  W. Eaglstein,et al.  Gold sodium thiomalate treatment of pemphigus. , 1973, Archives of dermatology.

[2]  R. N. Brogden,et al.  Auranofin. A preliminary review of its pharmacological properties and therapeutic use in rheumatoid arthritis. , 1984, Drugs.

[3]  D. Allara,et al.  Spontaneously organized molecular assemblies. 4. Structural characterization of n-alkyl thiol monolayers on gold by optical ellipsometry, infrared spectroscopy, and electrochemistry , 1987 .

[4]  H. Finklea,et al.  Blocking oriented monolayers of alkyl mercaptans on gold electrodes , 1987 .

[5]  Jacques Mugica,et al.  New perspectives in cardiac pacing , 1988 .

[6]  G. Whitesides,et al.  Formation of monolayer films by the spontaneous assembly of organic thiols from solution onto gold , 1989 .

[7]  J. Messenger,et al.  The Influence of Endocardial Electrode Fixation Status on Acute and Chronic Atrial Stimulation Threshold and Atrial Endocardial Electrogram Amplitude , 1990, Pacing and clinical electrophysiology : PACE.

[8]  G. Whitesides,et al.  Formation of self-assembled monolayers by chemisorption of derivatives of oligo(ethylene glycol) of structure HS(CH2)11(OCH2CH2)mOH on gold , 1991 .

[9]  MICHAEL SKALSKY,et al.  Active Fixation Leads—Long‐Term Threshold Reduction Using a Drug‐Infused Ceramic Collar , 1991, Pacing and clinical electrophysiology : PACE.

[10]  Activity-based pacing: comparison of a device using an accelerometer versus a piezoelectric crystal. , 1992, Pacing and clinical electrophysiology : PACE.

[11]  I. Rubinstein,et al.  Thioaromatic monolayers on gold: a new family of self-assembling monolayers , 1993 .

[12]  G. Payne,et al.  Clinical Experience with a New Lead Comhining Active Fixation with Steroid Elution , 1994, Pacing and clinical electrophysiology : PACE.

[13]  Kenneth A. Ellenbogen,et al.  Clinical Cardiac Pacing , 1995 .

[14]  W. Spencer,et al.  Steroid elution improves the stimulation threshold in an active-fixation atrial permanent pacing lead. A randomized, controlled study. Model 4068 Investigators. , 1995, Circulation.

[15]  A. Ulman,et al.  Formation and Structure of Self-Assembled Monolayers. , 1996, Chemical reviews.

[16]  A. Oto,et al.  Long-term clinical experience with a steroid-eluting active fixation ventricular electrode in children. , 1997, The American journal of cardiology.

[17]  M. Ho,et al.  Hydrolysis and Condensation of Self-Assembled Monolayers of (3-Mercaptopropyl)trimethoxysilane on Ag and Au Surfaces , 1997 .

[18]  Jeanne E. Pemberton,et al.  Air Stability of Alkanethiol Self-Assembled Monolayers on Silver and Gold Surfaces , 1998 .

[19]  Jeanne E. Pemberton,et al.  Effects of Electrolyte and Potential on the in Situ Structure of Alkanethiol Self-Assembled Monolayers on Silver , 1999 .