Evaluation of a green laser pointer for flow cytometry

Flow cytometers typically incorporate expensive lasers with high‐quality (TEM00) output beam structure and very stable output power, significantly increasing system cost and power requirements. Red diode lasers minimize power consumption and cost, but limit fluorophore selection. Low‐cost DPSS laser pointer modules could possibly offer increased wavelength selection but presumed emission instability has limited their use. A $160 DPSS 532 nm laser pointer module was first evaluated for noise characteristics and then used as the excitation light source in a custom‐built flow cytometer for the analysis of fluorescent calibration and alignment microspheres. Eight of ten modules tested were very quiet (RMS noise ≤ 0.6% between 0 and 5 MHz). With a quiet laser pointer module as the light source in a slow‐flow system, fluorescence measurements from alignment microspheres produced CVs of about 3.3%. Furthermore, the use of extended transit times and ≤1 mW of laser power produced both baseline resolution of all 8 peaks in a set of Rainbow microspheres, and a detection limit of <20 phycoerythrin molecules per particle. Data collected with the transit time reduced to 25 μs (in the same instrument but at 2.4 mW laser output) demonstrated a detection limit of ∼75 phycoerythrin molecules and CVs of about 2.7%. The performance, cost, size, and power consumption of the tested laser pointer module suggests that it may be suitable for use in conventional flow cytometry, particularly if it were coupled with cytometers that support extended transit times. Published 2007 Wiley‐Liss, Inc.

[1]  R. Keller,et al.  Ultrasensitive laser-induced fluorescence detection in hydrodynamically focused flows , 1987 .

[2]  Steven W Graves,et al.  Ultrasonic particle‐concentration for sheathless focusing of particles for analysis in a flow cytometer , 2006, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[3]  E Gottwald,et al.  Intracellular HSP72 detection in HL60 cells using a flow cytometry system based on microfluidic analysis. , 2003, BioTechniques.

[4]  D Barnett,et al.  Cytofluorometric methods for assessing absolute numbers of cell subsets in blood. European Working Group on Clinical Cell Analysis. , 2000, Cytometry.

[5]  H. Shapiro Practical Flow Cytometry: Shapiro/Flow Cytometry 4e , 2005 .

[6]  Thomas M. Yoshida,et al.  Development of a mechanism-based, DNA staining protocol using SYTOX orange nucleic acid stain and DNA fragment sizing flow cytometry. , 2000, Analytical biochemistry.

[7]  S. Takayama,et al.  Microfluidics for flow cytometric analysis of cells and particles , 2005, Physiological measurement.

[8]  Jeeseong Hwang,et al.  High-sensitivity bacterial detection using biotin-tagged phage and quantum-dot nanocomplexes. , 2006, Proceedings of the National Academy of Sciences of the United States of America.

[9]  Alan P. Morrison,et al.  Development of a microfluidic device for fluorescence activated cell sorting , 2002 .

[10]  Dmitri Ivnitski,et al.  Biosensors for detection of pathogenic bacteria , 1999 .

[11]  George Janossy,et al.  Precise CD4 T-cell counting using red diode laser excitation: for richer, for poorer. , 2002, Cytometry.

[12]  V. Imbert,et al.  Immunofluorescent quantification of tyrosine phosphorylation of cellular proteins in whole cells by flow cytometry. , 1994, Cytometry.

[13]  S. Takayama,et al.  Use of Air-Liquid Two-Phase Flow in Hydrophobic Microfluidic Channels for Disposable Flow Cytometers , 2002 .

[14]  J. Jett,et al.  Single DNA Fragment Detection by Flow Cytometry , 2002 .

[15]  O. C. Blair,et al.  Practical Flow Cytometry , 1985, The Yale Journal of Biology and Medicine.

[16]  Steven W Graves,et al.  Open, reconfigurable cytometric acquisition system: ORCAS , 2007, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[17]  K. Rowlen,et al.  Design and characterization of a compact dual channel virus counter , 2005, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[18]  R. Hoffman,et al.  Resolution of dimly fluorescent particles: a practical measure of fluorescence sensitivity. , 1998, Cytometry.

[19]  Robert C Habbersett,et al.  An analytical system based on a compact flow cytometer for DNA fragment sizing and single‐molecule detection , 2004, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[20]  W. Telford,et al.  Analysis of violet‐excited fluorochromes by flow cytometry using a violet laser diode , 2003, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[21]  S. Quake,et al.  A microfabricated fluorescence-activated cell sorter , 1999, Nature Biotechnology.

[22]  J. Jett,et al.  Attogram detection limit for aqueous dye samples by laser-induced fluorescence. , 1983, Science.

[23]  Hywel Morgan,et al.  High throughput particle analysis: combining dielectrophoretic particle focussing with confocal optical detection. , 2006, Biosensors & bioelectronics.

[24]  George Janossy,et al.  Multiplexed immunoassays by flow cytometry for diagnosis and surveillance of infectious diseases in resource-poor settings. , 2002, The Lancet. Infectious diseases.

[25]  J. Fahey,et al.  Impact of the international program for Quality Assessment and Standardization for Immunological Measures Relevant to HIV/AIDS: QASI. , 2002, Cytometry.

[26]  B. Autran,et al.  T-cell subset counting and the fight against AIDS: reflections over a 20-year struggle. , 2002, Cytometry.

[27]  Shuichi Takayama,et al.  Towards portable flow cytometry: study on the use of air-sheath-based volume-efficient two-phase microfluidic systems , 2002, Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology.

[28]  Jung Yul Yoo,et al.  Single-cell manipulation and fluorescence detection in benchtop flow cytometry system with disposable plastic microfluidic chip , 2003, SPIE MOEMS-MEMS.