The precision of fit of milled titanium implant frameworks (I-Bridge) in the edentulous jaw.

BACKGROUND New computer numeric controlled (CNC)-milled frameworks for implant-supported prostheses have been introduced. However, no data are available on the precision of fit of these new frameworks. PURPOSE The purpose of this study is to evaluate the precision of fit of a new CNC-milled framework technique (I-Bridge, Biomain AB, Helsingborg, Sweden) using Brånemark System (Nobel Biocare AB, Göteborg, Sweden) and NobelReplace (Nobel Biocare AB) system implants. MATERIALS AND METHODS Ten test frameworks were fabricated for one master model for each implant system. Five additional frameworks were fabricated for five different models simulating clinical cases as controls (Brånemark System). The distortion of implant center point positions was measured in x-, y-, and z-axes and in three dimensions by using a contact-type coordinate measuring machine and a computer program developed specifically for this purpose. Mann-Whitney U-test was used to compare differences of distortion within and between the groups. RESULTS The maximal distortion in arch width (x-axis) and curvature (y-axis) was within 71 and 55 microm for all frameworks, respectively. The mean distortion in absolute figures in x-, y-, z-axes and three dimensions was for "clinical control" frameworks 23, 26, 4, and 34 microm as compared with less than 12, 12, 2, and 17 microm for Brånemark and NobelReplace frameworks, respectively. Control frameworks showed significantly (p < .05) greater mean and range of distortions in x- and y-axes and in three dimensions compared with test frameworks. CONCLUSION All measured frameworks presented signs of misfit, indicating that no framework had a "passive fit." Frameworks produced in a more routine clinical environment seem to present greater levels of distortion as compared with frameworks produced in a strict test situation. However, all measured frameworks presented levels of precision of fit within limits considered to be clinically acceptable in earlier studies of frameworks placed on abutments.

[1]  T. Taylor,et al.  Strain Situation after Fixation of Three-Unit Ceramic Veneered Implant Superstructures , 2005, Implant dentistry.

[2]  I. E. Ruyter,et al.  Implant-fixed, dental bridges from carbon/graphite fibre reinforced poly(methyl methacrylate). , 1987, Biomaterials.

[3]  B R Lang,et al.  Fit of implant frameworks fabricated by different techniques. , 1997, The Journal of prosthetic dentistry.

[4]  U. Lekholm,et al.  Bone response to implant-supported frameworks with differing degrees of misfit preload: in vivo study in rabbits. , 2000, Clinical implant dentistry and related research.

[5]  L. Hjalmarsson,et al.  A 3-year retrospective study of Cresco frameworks: preload and complications. , 2005, Clinical implant dentistry and related research.

[6]  T Jemt,et al.  Precision of CNC-milled titanium frameworks for implant treatment in the edentulous jaw. , 1999, The International journal of prosthodontics.

[7]  G. Murray,et al.  Design of superstructures for osseointegrated fixtures. , 1985, Swedish dental journal. Supplement.

[8]  C Bessing,et al.  Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. , 1994, The International journal of oral & maxillofacial implants.

[9]  Toshiyuki Takahashi,et al.  Fit of implant frameworks: an in vitro comparison between two fabrication techniques. , 2003, The Journal of prosthetic dentistry.

[10]  T Jemt,et al.  Measurements of bone and frame-work deformations induced by misfit of implant superstructures. A pilot study in rabbits. , 1998, Clinical oral implants research.

[11]  I. E. Ruyter,et al.  Mechanical and physical properties of carbon-graphite fiber-reinforced polymers intended for implant suprastructures. , 2007, Dental materials : official publication of the Academy of Dental Materials.

[12]  M. Hulterström,et al.  Cobalt-chromium as a framework material in implant-supported fixed prostheses: a preliminary report. , 1991, The International journal of oral & maxillofacial implants.

[13]  T Jemt,et al.  Three-dimensional distortion of gold alloy castings and welded titanium frameworks. Measurements of the precision of fit between completed implant prostheses and the master casts in routine edentulous situations. , 1995, Journal of oral rehabilitation.

[14]  Riza Gurbuz,et al.  Structure and mechanical properties of Cresco-Ti laser-welded joints and stress analyses using finite element models of fixed distal extension and fixed partial prosthetic designs. , 2005, The Journal of prosthetic dentistry.

[15]  P. Branemark,et al.  Brånemark Novum: a new treatment concept for rehabilitation of the edentulous mandible. Preliminary results from a prospective clinical follow-up study. , 1999, Clinical implant dentistry and related research.

[16]  G. Gurtner,et al.  Statistics in medicine. , 2011, Plastic and reconstructive surgery.

[17]  T. Mattsson,et al.  Clinical performance of a method for the fabrication of implant-supported precisely fitting titanium frameworks: a retrospective 5- to 8-year clinical follow-up study. , 2004, Clinical implant dentistry and related research.

[18]  I Naert,et al.  A comparison of laser-welded titanium and conventional cast frameworks supported by implants in the partially edentulous jaw: a 3-year prospective multicenter study. , 2000, The International journal of prosthodontics.

[19]  C. D. Cromar A biographical study , 1959 .

[20]  George A Zarb,et al.  A comparison of the accuracy of fit of 2 methods for fabricating implant-prosthodontic frameworks. , 2007, The International journal of prosthodontics.

[21]  I. Naert,et al.  Biologic response of immediately versus delayed loaded implants supporting ill-fitting prostheses: an animal study. , 2005, Clinical implant dentistry and related research.

[22]  J. Lindhe,et al.  Bone reactions adjacent to titanium implants subjected to static load. A study in the dog (I). , 2001, Clinical oral implants research.

[23]  I Naert,et al.  The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study. , 2001, Clinical oral implants research.

[24]  Torsten Jemt,et al.  Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible. , 2003, The International journal of prosthodontics.

[25]  Antonio Scarano,et al.  Inflammatory infiltrate, microvessel density, nitric oxide synthase expression, vascular endothelial growth factor expression, and proliferative activity in peri-implant soft tissues around titanium and zirconium oxide healing caps. , 2006, Journal of periodontology.

[26]  S. Brush,et al.  Gauss: A Biographical Study , 1981 .

[27]  J. Rubenstein,et al.  Comparison of interface relationships between implant components for laser-welded titanium frameworks and standard cast frameworks. , 1999, The International journal of oral & maxillofacial implants.

[28]  T. Taylor,et al.  In vivo stress behavior in cemented and screw-retained five-unit implant FPDs. , 2006, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[29]  K. Nilner,et al.  A prospective 5-year multicenter study of the Cresco implantology concept. , 2003, The International journal of prosthodontics.

[30]  B R Lang,et al.  Measuring fit at the implant prosthodontic interface. , 1996, The Journal of prosthetic dentistry.

[31]  S. Palmqvist,et al.  Laser-welded titanium frameworks for implant-supported fixed prostheses: a 5-year report. , 1999, The International journal of oral & maxillofacial implants.

[32]  T. Jemt,et al.  Clinical experiences with laser-welded titanium frameworks supported by implants in the edentulous mandible: a 10-year follow-up study. , 2006, Clinical implant dentistry and related research.

[33]  B. Engquist,et al.  Simplified methods of implant treatment in the edentulous lower jaw: a 3-year follow-up report of a controlled prospective study of one-stage versus two-stage surgery and early loading. , 2005, Clinical implant dentistry and related research.

[34]  Sang-Wan Shin,et al.  Initial osteoblast-like cell response to pure titanium and zirconia/alumina ceramics. , 2007, Dental materials : official publication of the Academy of Dental Materials.

[35]  T. Jemt,et al.  Fixed implant-supported prostheses with welded titanium frameworks. , 1992, The International journal of periodontics & restorative dentistry.

[36]  T. Jemt,et al.  Clinical experiences with laser-welded titanium frameworks supported by implants in the edentulous mandible: a 5-year follow-up study. , 1999, The International journal of prosthodontics.

[37]  Torsten Jemt,et al.  Clinical experience of CNC-milled titanium frameworks supported by implants in the edentulous jaw: a 3-year interim report. , 2002, Clinical implant dentistry and related research.

[38]  I. E. Ruyter,et al.  Implant-fixed, dental bridges from carbon/graphite fibre reinforced poly (methyl methacrylate) , 1986 .