Contribution of a pumped-storage hydropower plant to reduce the scheduling costs of an isolated power system with high wind power penetration

The paper aims at demonstrating that the consideration of constant start-up costs and ramps of the thermal generating units for assessing the contribution of pumped-hydro energy storage to reduce the scheduling costs of hydrothermal power systems with high wind penetration, may yield unrealistic results. For this purpose, an isolated power system is used as a case study. The contribution of a pumped-storage hydropower plant to reduce the system scheduling costs is assessed in the paper by using a hydrothermal weekly unit commitment model. The model considers different start-up costs and ramps of the thermal generating units as a function of the start-up type. The effects of including pumped hydro energy storage in the system on the integration of wind energy, and on the start-ups and capacity factors of the thermal generating units are also evaluated. The results of the paper demonstrate that the consideration of constant start-up costs and ramps of the thermal generating units yields unrealistic results, and that the pumped-storage hydropower plant may help reduce the system scheduling costs by 2.5–11% and integrate wind power and may allow dispensing with some inflexible thermal generating units.

[1]  Sandra Bellekom,et al.  Electric cars and wind energy: Two problems, one solution? A study to combine wind energy and electric cars in 2020 in The Netherlands , 2012 .

[2]  Aidan Tuohy,et al.  Pumped storage in systems with very high wind penetration , 2011 .

[3]  J. P. Deane,et al.  Derivation of Intertemporal Targets for Large Pumped Hydro Energy Storage With Stochastic Optimization , 2013, IEEE Transactions on Power Systems.

[4]  M. Shahidehpour,et al.  Price-based unit commitment: a case of Lagrangian relaxation versus mixed integer programming , 2005, IEEE Transactions on Power Systems.

[5]  René M.J. Benders,et al.  Wind energy, electricity, and hydrogen in the Netherlands , 2007 .

[6]  John Michael Hagerty The role of hydroelectric generation in electric power systems with large scale wind generation , 2012 .

[7]  Filip Johnsson,et al.  Dispatch modeling of a regional power generation system – Integrating wind power , 2009 .

[8]  O. Nilsson,et al.  Hydro unit start-up costs and their impact on the short term scheduling strategies of Swedish power producers , 1997 .

[9]  Giorgio Locatelli,et al.  Assessing the economics of large Energy Storage Plants with an optimisation methodology , 2015 .

[10]  Hao Tian,et al.  Improved gravitational search algorithm for unit commitment considering uncertainty of wind power , 2014, Energy.

[11]  A. Bakirtzis,et al.  Optimal Self-Scheduling of a Thermal Producer in Short-Term Electricity Markets by MILP , 2010, IEEE Transactions on Power Systems.

[12]  G. Sheblé,et al.  Power generation operation and control — 2nd edition , 1996 .

[13]  R.D. Naidoo A Mixed Integer Programming formulation of generator startup costs , 2007, 2007 International Power Engineering Conference (IPEC 2007).

[14]  John S. Anagnostopoulos,et al.  Study of pumped storage schemes to support high RES penetration in the electric power system of Greece , 2012 .

[15]  Anastasios G. Bakirtzis,et al.  A genetic algorithm solution to the unit commitment problem , 1996 .

[16]  E. Denny,et al.  The viability of balancing wind generation with storage , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[17]  W.L. Kling,et al.  Impacts of Wind Power on Thermal Generation Unit Commitment and Dispatch , 2007, IEEE Transactions on Energy Conversion.

[18]  Alireza Soroudi,et al.  Robust optimization based self scheduling of hydro-thermal Genco in smart grids , 2013 .

[19]  Sajad Jafari,et al.  Pumped-storage unit commitment with considerations for energy demand, economics, and environmental constraints , 2010 .

[20]  M. O'Malley,et al.  The relationship between base-load generation, start-up costs and generation cycling , 2008 .

[21]  Li Mo,et al.  Short-term hydrothermal generation scheduling using differential real-coded quantum-inspired evolutionary algorithm , 2012 .

[22]  Andres Ramos,et al.  Tight and Compact MILP Formulation of Start-Up and Shut-Down Ramping in Unit Commitment , 2013, IEEE Transactions on Power Systems.

[23]  Reinerus Benders,et al.  The application of power-to-gas, pumped hydro storage and compressed air energy storage in an electricity system at different wind power penetration levels , 2014 .

[24]  Joachim Raabe,et al.  Hydro power: The design, use, and function of hydromechanical, hydraulic, and electrical equipment , 1985 .

[25]  Kang Li,et al.  A long-term analysis of pumped hydro storage to firm wind power , 2015 .

[26]  Allen J. Wood,et al.  Power Generation, Operation, and Control , 1984 .

[27]  Ramesh C. Bansal,et al.  On some of the design aspects of wind energy conversion systems , 2002 .

[28]  Mohammad Shahidehpour,et al.  The IEEE Reliability Test System-1996. A report prepared by the Reliability Test System Task Force of the Application of Probability Methods Subcommittee , 1999 .

[29]  Mohammad Shahidehpour,et al.  Transmission-constrained intrahour coordination of wind and pumped-storage hydro units , 2013 .

[30]  Mohammad Shahidehpour,et al.  Enhancing the Dispatchability of Variable Wind Generation by Coordination With Pumped-Storage Hydro Units in Stochastic Power Systems , 2013, IEEE Transactions on Power Systems.

[31]  Jose R. Wilhelmi,et al.  Optimal short-term operation and sizing of pumped-storage power plants in systems with high penetration of wind energy , 2010, 2010 7th International Conference on the European Energy Market.

[32]  Michael Milligan,et al.  Enhancing hydropower modeling in variable generation integration studies , 2014 .

[33]  J. A. Carta,et al.  Technical–economic analysis of wind-powered pumped hydrostorage systems. Part I: model development , 2005 .

[34]  J. H. Zheng,et al.  Reliability constrained unit commitment with combined hydro and thermal generation embedded using self-learning group search optimizer , 2015 .

[35]  A. Merlin,et al.  A New Method for Unit Commitment at Electricite De France , 1983, IEEE Transactions on Power Apparatus and Systems.

[36]  G. Strbac,et al.  Value of Bulk Energy Storage for Managing Wind Power Fluctuations , 2007, IEEE Transactions on Energy Conversion.

[37]  José A. Carta,et al.  Wind powered pumped hydro storage systems, a means of increasing the penetration of renewable energy in the Canary Islands , 2006 .

[38]  Wil L. Kling,et al.  Integration of large-scale wind power and use of energy storage in the netherlands' electricity supply , 2008 .