Recent advances in recording electrophysiological data simultaneously with magnetic resonance imaging

Simultaneous recording of brain activity by different neurophysiological modalities can yield insights that reach beyond those obtained by each technique individually, even when compared to those from the post-hoc integration of results from each technique recorded sequentially. Success in the endeavour of real-time multimodal experiments requires special hardware and software as well as purpose-tailored experimental design and analysis strategies. Here, we review the key methodological issues in recording electrophysiological data in humans simultaneously with magnetic resonance imaging (MRI), focusing on recent technical and analytical advances in the field. Examples are derived from simultaneous electroencephalography (EEG) and electromyography (EMG) during functional MRI in cognitive and systems neuroscience as well as in clinical neurology, in particular in epilepsy and movement disorders. We conclude with an outlook on current and future efforts to achieve true integration of electrical and haemodynamic measures of neuronal activity using data fusion models.

[1]  M Seeck,et al.  Functional MRI with simultaneous EEG recording: Feasibility and application to motor and visual activation , 2001, Journal of magnetic resonance imaging : JMRI.

[2]  N. Logothetis,et al.  Negative functional MRI response correlates with decreases in neuronal activity in monkey visual area V1 , 2006, Nature Neuroscience.

[3]  Febo Cincotti,et al.  Multimodal integration of high-resolution EEG and functional magnetic resonance imaging data: a simulation study , 2003, NeuroImage.

[4]  Bruno Maraviglia,et al.  Hemodynamic response (BOLD/fMRI) in focal epilepsy with reference to benzodiazepine effect. , 2004, Magnetic resonance imaging.

[5]  O. Josephs,et al.  EEG recording during fMRI experiments: Image quality , 2000, Human brain mapping.

[6]  Hellmuth Obrig,et al.  Correlates of alpha rhythm in functional magnetic resonance imaging and near infrared spectroscopy , 2003, NeuroImage.

[7]  Robert Turner,et al.  A Method for Removing Imaging Artifact from Continuous EEG Recorded during Functional MRI , 2000, NeuroImage.

[8]  S. Debener,et al.  Effects of simultaneous EEG recording on MRI data quality at 1.5, 3 and 7 tesla. , 2008, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[9]  B. Feige,et al.  Cortical and subcortical correlates of electroencephalographic alpha rhythm modulation. , 2005, Journal of neurophysiology.

[10]  Kenneth Hugdahl,et al.  Assessing the spatiotemporal evolution of neuronal activation with single-trial event-related potentials and functional MRI. , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[11]  Richard S. J. Frackowiak,et al.  Endogenous Cortical Rhythms Determine Cerebral Specialization for Speech Perception and Production , 2007, Neuron.

[12]  Karl J. Friston,et al.  MEG source localization under multiple constraints: An extended Bayesian framework , 2006, NeuroImage.

[13]  Douglas C Noll,et al.  A modified electrode cap for EEG recordings in MRI scanners , 1999, Clinical Neurophysiology.

[14]  Nikos K Logothetis,et al.  Simultaneous EEG and fMRI in the macaque monkey at 4.7 Tesla. , 2005, Magnetic resonance imaging.

[15]  Michiro Negishi,et al.  Removal of time-varying gradient artifacts from EEG data acquired during continuous fMRI , 2004, Clinical Neurophysiology.

[16]  Hyun Wook Park,et al.  Improved ballistocardiac artifact removal from the electroencephalogram recorded in fMRI , 2004, Journal of Neuroscience Methods.

[17]  S Warach,et al.  Monitoring the patient's EEG during echo planar MRI. , 1993, Electroencephalography and clinical neurophysiology.

[18]  M. Fukunaga,et al.  Low frequency BOLD fluctuations during resting wakefulness and light sleep: A simultaneous EEG‐fMRI study , 2008, Human brain mapping.

[19]  B. Condon,et al.  Investigation of the factors responsible for burns during MRI , 2001, Journal of magnetic resonance imaging : JMRI.

[20]  A. Engel,et al.  Trial-by-Trial Coupling of Concurrent Electroencephalogram and Functional Magnetic Resonance Imaging Identifies the Dynamics of Performance Monitoring , 2005, The Journal of Neuroscience.

[21]  Mark W. Woolrich,et al.  Probabilistic diffusion tractography with multiple fibre orientations: What can we gain? , 2007, NeuroImage.

[22]  Daniel Brandeis,et al.  Synchronization facilitates removal of MRI artefacts from concurrent EEG recordings and increases usable bandwidth , 2006, NeuroImage.

[23]  Helmut Laufs,et al.  Where the BOLD signal goes when alpha EEG leaves , 2006, NeuroImage.

[24]  Anneke Steens,et al.  Reduced cortical activity during maximal bilateral contractions of the index finger , 2007, NeuroImage.

[25]  K Bachmann,et al.  Effects of magnetic resonance imaging on cardiac pacemakers and electrodes. , 1997, American heart journal.

[26]  Hamid Soltanian-Zadeh,et al.  Integrated MEG/EEG and fMRI model based on neural masses , 2006, IEEE Transactions on Biomedical Engineering.

[27]  V Menon,et al.  Combined EEG and fMRI studies of human brain function. , 2005, International review of neurobiology.

[28]  J W Belliveau,et al.  Visual evoked potential (VEP) measured by simultaneous 64-channel EEG and 3T fMRI. , 1999, Neuroreport.

[29]  Reto Meuli,et al.  Radiofrequency heating effects around resonant lengths of wire in MRI. , 2002, Physics in medicine and biology.

[30]  S. Debener,et al.  Properties of the ballistocardiogram artefact as revealed by EEG recordings at 1.5, 3 and 7 T static magnetic field strength. , 2008, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[31]  Jens Frahm,et al.  Task- and EEG-correlated analyses of BOLD MRI responses to eyes opening and closing , 2006, Brain Research.

[32]  Giorgio Bonmassar,et al.  On the effect of resistive EEG electrodes and leads during 7 T MRI: simulation and temperature measurement studies. , 2006, Magnetic resonance imaging.

[33]  R. J Dolan,et al.  Activity in ventromedial prefrontal cortex covaries with sympathetic skin conductance level: a physiological account of a “default mode” of brain function , 2004, NeuroImage.

[34]  G. Srivastava,et al.  ICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner , 2005, NeuroImage.

[35]  Jean A. Tkach,et al.  Parkinson disease: pattern of functional MR imaging activation during deep brain stimulation of subthalamic nucleus--initial experience. , 2006, Radiology.

[36]  A. Kleinschmidt,et al.  Simultaneous Recording of Cerebral Blood Oxygenation Changes during Human Brain Activation by Magnetic Resonance Imaging and Near-Infrared Spectroscopy , 1996, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[37]  Helmut Laufs,et al.  'Brain activation and hypothalamic functional connectivity during human non-rapid eye movement sleep: an EEG/fMRI study'--its limitations and an alternative approach. , 2007, Brain : a journal of neurology.

[38]  Louis Lemieux,et al.  EEG/Functional MRI in Epilepsy: The Queen Square Experience , 2004, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[39]  N. Logothetis,et al.  Neurophysiological investigation of the basis of the fMRI signal , 2001, Nature.

[40]  Timothy Edward John Behrens,et al.  A Bayesian framework for global tractography , 2007, NeuroImage.

[41]  Kazuki Iwata,et al.  Artifact reduction for simultaneous EEG/fMRI recording: Adaptive FIR reduction of imaging artifacts , 2006, Clinical Neurophysiology.

[42]  David Poeppel,et al.  How can EEG/MEG and fMRI/PET data be combined? , 2002, Human brain mapping.

[43]  H. Laufs,et al.  Electroencephalography/functional MRI in human epilepsy: what it currently can and cannot do , 2007, Current opinion in neurology.

[44]  A A Snisarenko The cardiac rhythm during waking and the various periods of sleep. , 1978, Human physiology.

[45]  Karsten Krakow,et al.  Spontaneous dissociation during functional MRI experiments. , 2007, Journal of psychiatric research.

[46]  Rami K. Niazy,et al.  Removal of FMRI environment artifacts from EEG data using optimal basis sets , 2005, NeuroImage.

[47]  J. Belliveau,et al.  Metallic electrodes and leads in simultaneous EEG‐MRI: Specific absorption rate (SAR) simulation studies , 2004, Bioelectromagnetics.

[48]  Karl J. Friston,et al.  Statistical parametric mapping , 2013 .

[49]  Carsten Meyer,et al.  Combining Algorithms in Automatic Detection of QRS Complexes in ECG Signals , 2006, IEEE Transactions on Information Technology in Biomedicine.

[50]  Robin Goldman,et al.  Tomographic mapping of alpha rhythm using simultaneous EEG/fMRI , 2001, NeuroImage.

[51]  Bruno Rossion,et al.  Parametric design and correlational analyses help integrating fMRI and electrophysiological data during face processing , 2004, NeuroImage.

[52]  Helmut Laufs,et al.  ELP06 Impact of interictal secondarily-generalized activity on brain function in epileptic encephalopathy: an EEG-fMRI study , 2007 .

[53]  Emery N. Brown,et al.  Motion and Ballistocardiogram Artifact Removal for Interleaved Recording of EEG and EPs during MRI , 2002, NeuroImage.

[54]  L. Lemieux,et al.  Modelling large motion events in fMRI studies of patients with epilepsy. , 2007, Magnetic resonance imaging.

[55]  Snisarenko Aa,et al.  The cardiac rhythm during waking and the various periods of sleep. , 1978 .

[56]  L Bozzao,et al.  Real-time MR artifacts filtering during continuous EEG/fMRI acquisition. , 2003, Magnetic resonance imaging.

[57]  Frédéric Grouiller,et al.  A comparative study of different artefact removal algorithms for EEG signals acquired during functional MRI , 2007, NeuroImage.

[58]  Giorgio Bonmassar,et al.  EEG/(f)MRI measurements at 7 Tesla using a new EEG cap (“InkCap”) , 2006, NeuroImage.

[59]  Jens Frahm,et al.  Simultaneous recordings of visual evoked potentials and BOLD MRI activations in response to visual motion processing , 2005, NMR in biomedicine.

[60]  Karl J. Friston,et al.  EEG–fMRI of idiopathic and secondarily generalized epilepsies , 2006, NeuroImage.

[61]  Karl J. Friston,et al.  Modelling cardiac signal as a confound in EEG-fMRI and its application in focal epilepsy studies , 2006, NeuroImage.

[62]  Nelson J. Trujillo-Barreto,et al.  Realistically Coupled Neural Mass Models Can Generate EEG Rhythms , 2007, Neural Computation.

[63]  J Sijbers,et al.  Restoration of MR-induced artifacts in simultaneously recorded MR/EEG data. , 1999, Magnetic resonance imaging.

[64]  Hugo D. Critchley,et al.  Brain activity relating to the contingent negative variation: an fMRI investigation , 2004, NeuroImage.

[65]  Natasha M. Maurits,et al.  Surface EMG measurements during fMRI at 3T: Accurate EMG recordings after artifact correction , 2005, NeuroImage.

[66]  J Riera,et al.  Fusing EEG and fMRI based on a bottom-up model: inferring activation and effective connectivity in neural masses , 2005, Philosophical Transactions of the Royal Society B: Biological Sciences.

[67]  William D. Penny,et al.  CHAPTER 25 – Spatio-temporal models for fMRI , 2007 .

[68]  J Sijbers,et al.  Special designed RF-antenna with integrated non-invasive carbon electrodes for simultaneous magnetic resonance imaging and electroencephalography acquisition at 7T. , 2000, Magnetic resonance imaging.

[69]  S. Debener,et al.  Simultaneous recording of EEG and BOLD responses: a historical perspective. , 2008, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[70]  F. Vargha-Khadem,et al.  Impact of interictal epileptic activity on normal brain function in epileptic encephalopathy: An electroencephalography–functional magnetic resonance imaging study , 2007, Epilepsy & Behavior.

[71]  John S. Duncan,et al.  BOLD and perfusion changes during epileptic generalised spike wave activity , 2008, NeuroImage.

[72]  Kristina M. Ropella,et al.  Ballistocardiogram artifact reduction in the simultaneous acquisition of auditory ERPS and fMRI , 2004, NeuroImage.

[73]  Gian Luca Romani,et al.  Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis , 2007, NeuroImage.

[74]  K J Werhahn,et al.  Electroencephalography during functional echo‐planar imaging: Detection of epileptic spikes using post‐processing methods , 2000, Magnetic resonance in medicine.

[75]  Deborah A. Vitacco,et al.  Correspondence of event‐related potential tomography and functional magnetic resonance imaging during language processing , 2002, Human brain mapping.

[76]  Louis Lemieux,et al.  Identification of EEG Events in the MR Scanner: The Problem of Pulse Artifact and a Method for Its Subtraction , 1998, NeuroImage.

[77]  Seppo P. Ahlfors,et al.  Geometrical interpretation of fMRI-guided MEG/EEG inverse estimates , 2004, NeuroImage.

[78]  Nelson J. Trujillo-Barreto,et al.  Bayesian model averaging in EEG/MEG imaging , 2004, NeuroImage.

[79]  Bradley G. Goodyear,et al.  Simultaneous 3-T fMRI and high-density recording of human auditory evoked potentials , 2004, NeuroImage.

[80]  G. Iannetti,et al.  BOLD functional MRI in disease and pharmacological studies: room for improvement? , 2007, Magnetic resonance imaging.

[81]  Arno Villringer,et al.  Visual evoked potentials recovered from fMRI scan periods , 2005, Human brain mapping.

[82]  F Kruggel,et al.  Recording of the event‐related potentials during functional MRI at 3.0 Tesla field strength , 2000, Magnetic resonance in medicine.

[83]  Manuel Schabus,et al.  Hemodynamic cerebral correlates of sleep spindles during human non-rapid eye movement sleep , 2007, Proceedings of the National Academy of Sciences.

[84]  A. Kleinschmidt,et al.  Electroencephalographic signatures of attentional and cognitive default modes in spontaneous brain activity fluctuations at rest , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[85]  Wolfgang Skrandies,et al.  Global field power and topographic similarity , 2005, Brain Topography.

[86]  Andrzej Cichocki,et al.  Removal of ballistocardiogram artifacts from simultaneously recorded EEG and fMRI data using independent component analysis , 2006, IEEE Transactions on Biomedical Engineering.

[87]  M. Scherg,et al.  Mental Chronometry of Working Memory Retrieval: A Combined Functional Magnetic Resonance Imaging and Event-Related Potentials Approach , 2006, The Journal of Neuroscience.

[88]  Jean Gotman,et al.  Concordance between distributed EEG source localization and simultaneous EEG-fMRI studies of epileptic spikes , 2008, NeuroImage.

[89]  Alberto Inuggi,et al.  Visual evoked potentials may be recorded simultaneously with fMRI scanning: A validation study , 2005, Human brain mapping.

[90]  J. Gotman,et al.  Generalized epileptic discharges show thalamocortical activation and suspension of the default state of the brain. , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[91]  Karl J. Friston,et al.  Variational Bayesian inversion of the equivalent current dipole model in EEG/MEG , 2008, NeuroImage.

[92]  Stephan Wolff,et al.  Spatial filters and automated spike detection based on brain topographies improve sensitivity of EEG–fMRI studies in focal epilepsy , 2007, NeuroImage.

[93]  M. Czisch,et al.  Brain activation and hypothalamic functional connectivity during human non-rapid eye movement sleep: an EEG/fMRI study. , 2006, Brain : a journal of neurology.

[94]  M. Scherg,et al.  Localizing P300 Generators in Visual Target and Distractor Processing: A Combined Event-Related Potential and Functional Magnetic Resonance Imaging Study , 2004, The Journal of Neuroscience.

[95]  Karl J. Friston,et al.  Anatomically Informed Basis Functions for EEG Source Localization: Combining Functional and Anatomical Constraints , 2002, NeuroImage.

[96]  Bettina Sorger,et al.  Improved quality of auditory event-related potentials recorded simultaneously with 3-T fMRI: Removal of the ballistocardiogram artefact , 2007, NeuroImage.

[97]  R G Hoffmann,et al.  Determination of drug‐induced changes in functional MRI signal using a pharmacokinetic model , 1999, Human brain mapping.

[98]  M. Corbetta,et al.  Electrophysiological signatures of resting state networks in the human brain , 2007, Proceedings of the National Academy of Sciences.

[99]  A. Villringer,et al.  Simultaneous EEG–fMRI , 2006, Neuroscience & Biobehavioral Reviews.

[100]  Jean Gotman,et al.  Negative BOLD responses to epileptic spikes , 2006, Human brain mapping.

[101]  K. Chiappa,et al.  EEG during MR imaging , 1995, Neurology.

[102]  G L Shulman,et al.  INAUGURAL ARTICLE by a Recently Elected Academy Member:A default mode of brain function , 2001 .

[103]  Andrew P. Bagshaw,et al.  Single trial variability of EEG and fMRI responses to visual stimuli , 2007, NeuroImage.

[104]  J. Gotman,et al.  Combining EEG and fMRI: A multimodal tool for epilepsy research , 2006, Journal of magnetic resonance imaging : JMRI.

[105]  Karl J. Friston,et al.  Comparing hemodynamic models with DCM , 2007, NeuroImage.

[106]  Andreas Kleinschmidt,et al.  EEG-correlated fMRI of human alpha activity , 2003, NeuroImage.

[107]  Karl J. Friston,et al.  Hemodynamic correlates of EEG: A heuristic , 2005, NeuroImage.

[108]  D. Heeger,et al.  In this issue , 2002, Nature Reviews Drug Discovery.

[109]  L. Lemieux,et al.  Recording of EEG during fMRI experiments: Patient safety , 1997, Magnetic resonance in medicine.

[110]  Dieter Vaitl,et al.  Relationship between regional hemodynamic activity and simultaneously recorded EEG‐theta associated with mental arithmetic‐induced workload , 2007, Human brain mapping.

[111]  A K Liu,et al.  Spatiotemporal imaging of human brain activity using functional MRI constrained magnetoencephalography data: Monte Carlo simulations. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[112]  Byron L. Lam,et al.  Visual Evoked Potential , 2005 .

[113]  N. Trujillo-Barreto,et al.  Bayesian model for EEG/MEG and fMRI data fusion , 2001, NeuroImage.

[114]  Tracy Warbrick,et al.  Scanning strategies for simultaneous EEG-fMRI evoked potential studies at 3 T. , 2008, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[115]  穴見 公隆,et al.  Stepping stone sampling for retrieving artifact-free electroencephalogram during functional magnetic resonance imaging , 2005 .

[116]  T Landis,et al.  Non-invasive epileptic focus localization using EEG-triggered functional MRI and electromagnetic tomography. , 1998, Electroencephalography and clinical neurophysiology.

[117]  Soo Yeol Lee,et al.  A technique to consider mismatches between fMRI and EEG/MEG sources for fMRI-constrained EEG/MEG source imaging: a preliminary simulation study , 2006, Physics in medicine and biology.

[118]  Jean Gotman,et al.  Hemodynamic Responses to Interictal Epileptiform Discharges in Children with Symptomatic Epilepsy , 2007, Epilepsia.

[119]  Jean Gotman,et al.  EEG–fMRI of epileptic spikes: Concordance with EEG source localization and intracranial EEG , 2006, NeuroImage.

[120]  Giorgio Bonmassar,et al.  Influence of EEG electrodes on the BOLD fMRI signal , 2001, Human brain mapping.

[121]  Peter A. Bandettini,et al.  Task-Independent Functional Brain Activity Correlation with Skin Conductance Changes: An fMRI Study , 2002, NeuroImage.

[122]  L. G. Hanson,et al.  Encoding of EEG in MR images , 2007 .

[123]  Jérémie Mattout,et al.  Symmetrical event-related EEG/fMRI information fusion in a variational Bayesian framework , 2007, NeuroImage.

[124]  G H Glover,et al.  Image‐based method for retrospective correction of physiological motion effects in fMRI: RETROICOR , 2000, Magnetic resonance in medicine.

[125]  Nelson J. Trujillo-Barreto,et al.  A symmetrical Bayesian model for fMRI and EEG/MEG neuroimage fusion , 2001 .

[126]  Robert Turner,et al.  BOLD correlates of EMG spectral density in cortical myoclonus: Description of method and case report , 2006, NeuroImage.

[127]  J.-M. Lina,et al.  Assessing the relevance of fMRI-based prior in the EEG inverse problem: a bayesian model comparison approach , 2005, IEEE Transactions on Signal Processing.

[128]  E. Halgren,et al.  Dynamic Statistical Parametric Mapping Combining fMRI and MEG for High-Resolution Imaging of Cortical Activity , 2000, Neuron.

[129]  A. Engel,et al.  Single-trial EEG–fMRI reveals the dynamics of cognitive function , 2006, Trends in Cognitive Sciences.

[130]  John S. Thornton,et al.  Functional MRI with active, fully implanted, deep brain stimulation systems: Safety and experimental confounds , 2007, NeuroImage.

[131]  Karl J. Friston,et al.  Studying spontaneous EEG activity with fMRI , 2003, Brain Research Reviews.

[132]  Mark S. Cohen,et al.  Acquiring simultaneous EEG and functional MRI , 2000, Clinical Neurophysiology.

[133]  J. Gotman,et al.  Quality of EEG in simultaneous EEG-fMRI for epilepsy , 2003, Clinical Neurophysiology.

[134]  A. Kleinschmidt,et al.  Linking Generalized Spike‐and‐Wave Discharges and Resting State Brain Activity by Using EEG/fMRI in a Patient with Absence Seizures , 2006, Epilepsia.

[135]  A. Kleinschmidt,et al.  Effects of sedation, stimulation, and placebo on cerebral blood oxygenation: a magnetic resonance neuroimaging study of psychotropic drug action , 1999, NMR in biomedicine.

[136]  G. Curio,et al.  Dipole source localization and fMRI of simultaneously recorded data applied to somatosensory categorization , 2003, NeuroImage.

[137]  Karl J. Friston,et al.  Comparing dynamic causal models , 2004, NeuroImage.

[138]  M. Roth,et al.  Single‐trial analysis of oddball event‐related potentials in simultaneous EEG‐fMRI , 2007, Human brain mapping.

[139]  J R Ives,et al.  EEG-triggered echo-planar functional MRI in epilepsy , 1996, Neurology.

[140]  Maquet,et al.  Functional neuroimaging of normal human sleep by positron emission tomography , 2000, Journal of sleep research.

[141]  R. Oostenveld,et al.  Frontal theta EEG activity correlates negatively with the default mode network in resting state. , 2008, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[142]  V. Tronnier,et al.  Active deep brain stimulation during MRI: A feasibility study , 2004, Magnetic resonance in medicine.

[143]  A. Kleinschmidt,et al.  Temporal lobe interictal epileptic discharges affect cerebral activity in “default mode” brain regions , 2006, Human brain mapping.

[144]  D. W. Carmichael,et al.  Safety of localising intracranial EEG electrodes using MRI , 2007 .