Long-term follow-up of pyrolytic carbon metacarpophalangeal implants.

BACKGROUND The metacarpophalangeal joint is the most commonly involved joint when rheumatoid arthritis affects the hand. Many prosthetic implants have been designed for the replacement of this joint. Although studies of these implants have shown relief of pain, they have generally demonstrated a poor range of motion, progression of ulnar drift, and bone loss, as well as failure, fracture, and dislocation of the implant. METHODS From December 1979 to February 1987, 151 pyrolytic carbon metacarpophalangeal implants were inserted in fifty-three patients. The implants had an articulating, unconstrained design with a hemispherical head and grooved, offset stems. Forty-four patients had rheumatoid arthritis; five, posttraumatic arthritis; three, osteoarthritis; and one, systemic lupus erythematosus. Three patients (eleven implants) were lost to long-term follow-up, and twenty patients (fifty-one functioning implants) died after the implant had been in situ for an average of 7.2 years. Eighteen implants (12 percent) in eleven patients were revised. Fourteen of the eighteen implants were replaced with a silicone-elastomer or another type of implant, and the remaining four were removed and a pyrolytic carbon implant was reinserted with the addition of bone cement or bone graft, or both. Twenty-six patients (seventy-one implants) were available for long-term review at an average of 11.7 years (range, 10.1 to 16.0 years) after implantation. RESULTS The implants improved the arc of motion of the fingers by an average of 13 degrees and elevated the arc by an average of 16 degrees. As a result, fingers were in a more functional, extended position. A complete set of preoperative, postoperative, and follow-up radiographs was available for fifty-three of the seventy-one implants that were followed long term. There was a high prevalence of joint stability: fifty (94 percent) of the fifty-three implants were in a reduced position postoperatively, and forty-one (82 percent) of those fifty implants were still in the postoperative reduced position at the time of long-term follow-up. Ulnar deviation averaged 20 degrees preoperatively and 19 degrees at the time of follow-up, with only the long finger having an increase in deviation. No adverse remodeling or resorption of bone was seen. Fifty (94 percent) of the fifty-three implants had evidence of osseointegration, with sclerosis around the end and shaft of the prosthetic stems. Radiolucent changes were seen adjacent to twelve implants. There was minimum-to-moderate subsidence (four millimeters or less) of thirty-four implants; most of the subsidence occurred immediately postoperatively. Survivorship analysis demonstrated an average annual failure rate of 2.1 percent and a sixteen-year survival rate of 70.3 percent. The five and ten-year survival rates were 82.3 percent (95 percent confidence interval, 74.6 to 88.2 percent) and 81.4 percent (95 percent confidence interval, 73.0 to 87.8 percent), respectively. None of the revised implants had any visible changes of wear or deformity of the surfaces or stems. Four instances of chronic inflammatory tissue and three instances of proliferative synovitis were noted histologically. Focal pigment deposits were seen in three fingers, one of which had removal of the implant two months after a fracture. No evidence of intracellular particles or particulate synovitis was found. CONCLUSIONS The results of this study demonstrate that pyrolytic carbon is a biologically and biomechanically compatible, wear-resistant, and durable material for arthroplasty of the metacarpophalangeal joint.

[1]  P. Branemark,et al.  Metacarpophalangeal joint replacement with osseointegrated endoprostheses. , 1986, Scandinavian journal of plastic and reconstructive surgery.

[2]  B. Levack,et al.  Metacarpo-phalangeal joint replacement with a new prosthesis: description and preliminary results of treatment with the Helal flap joint. , 1987, Journal of hand surgery.

[3]  S. Cook,et al.  Pyrolite carbon implants in the metacarpophalangeal joint of baboons. , 1983, Orthopedics.

[4]  R. Linscheid,et al.  Review and analysis of silicone-rubber metacarpophalangeal implants. , 1976, The Journal of bone and joint surgery. American volume.

[5]  Y. Wilson,et al.  Long-Term Follow-Up of Swanson’s Silastic Arthroplasty of the Metacarpophalangeal Joints in Rheumatoid Arthritis , 1993, Journal of hand surgery.

[6]  A. Swanson,et al.  The host response to silicone elastomer implants for small joint arthroplasty. , 1995, The Journal of hand surgery.

[7]  Proposed digital arthroplasty critical study of the preliminary results. , 1988, Annales de chirurgie de la main : organe officiel des societes de chirurgie de la main.

[8]  K. Doi,et al.  Alumina ceramic finger implants: a preliminary biomaterial and clinical evaluation. , 1984, The Journal of hand surgery.

[9]  K K Hansraj,et al.  Swanson metacarpophalangeal joint arthroplasty in patients with rheumatoid arthritis. , 1997, Clinical orthopaedics and related research.

[10]  J. BotellaLlusiá,et al.  [Long-term results]. , 1983, Anales de la Real Academia Nacional de Medicina.

[11]  Proposition pour une arthroplastie digitaleEtude critique des premiers rsultats , 1988 .

[12]  J. Buckwalter,et al.  Metacarpophalangeal joint implant arthroplasty with a Silastic spacer. , 1984, The Journal of bone and joint surgery. American volume.

[13]  G. Scuderi**,et al.  Survivorship of cemented knee replacements. , 1989, The Journal of bone and joint surgery. British volume.

[14]  A. Flatt RESTORATION OF RHEUMATOID FINGER-JOINT FUNCTION. , 1963, The Journal of bone and joint surgery. American volume.

[15]  S. Varma,et al.  The Nicolle Finger Joint Prosthesis: A Reappraisal , 1991, Journal of hand surgery.

[16]  J. Buckwalter,et al.  Metacarpophalangeal Joint Arthroplasty with a Metallic Hinged Prosthesis , 1984, Clinical orthopaedics and related research.

[17]  J. Jeffs,et al.  Experience with Silastic prostheses in the rheumatoid hand. A 5-year follow-up. , 1978, Annals of the rheumatic diseases.

[18]  A. Swanson,et al.  Bone remodeling phenomena in flexible implant arthroplasty in the metacarpophalangeal joints. Long-term study. , 1986, Clinical orthopaedics and related research.

[19]  J. Rand,et al.  Survivorship analysis of total knee arthroplasty. Cumulative rates of survival of 9200 total knee arthroplasties. , 1991, The Journal of bone and joint surgery. American volume.

[20]  R. W. Hakstian,et al.  Ulnar Deviation of the Fingers: The Role Of Joint Structure And Function , 1967 .

[21]  B. Adams,et al.  Schultz metacarpophalangeal arthroplasty: a long-term follow-up study. , 1990, The Journal of hand surgery.

[22]  S. Cook,et al.  The influence of implant elastic modulus on the stress distribution around LTI carbon and aluminum oxide dental implants. , 1981, Journal of biomedical materials research.

[23]  M A Ritter,et al.  Long-term comparison of the Charnley, Muller, and Trapezoidal-28 total hip prostheses. A survival analysis. , 1987, The Journal of arthroplasty.

[24]  H. Gellman,et al.  Sequential infection of silicone metacarpophalangeal joint arthroplasties resulting from skin breakdown. , 1992, The Journal of hand surgery.

[25]  R. Haddad,et al.  The effect of surface treatments on the interface mechanics of LTI pyrolytic carbon implants. , 1985, Journal of biomedical materials research.

[26]  E. W. Brannon,et al.  Experiences with a finger-joint prosthesis. , 1959, The Journal of bone and joint surgery. American volume.

[27]  Murakata La,et al.  Silicone lymphadenopathy with concomitant malignant lymphoma. , 1989 .

[28]  D W Murray,et al.  Survival analysis of joint replacements. , 1993, The Journal of bone and joint surgery. British volume.

[29]  J. J. Niebauer,et al.  Long-term follow-up of metacarpal phalangeal arthroplasty with silicone Dacron prostheses. , 1986, The Journal of hand surgery.

[30]  T. C. Whitmore,et al.  Long-term study , 1991, Nature.

[31]  Rupert G. Miller,et al.  Survival Analysis , 2022, The SAGE Encyclopedia of Research Design.

[32]  Haubold Ad On the durability of pyrolytic carbon in vivo. , 1994 .

[33]  A. Flatt Restoration of Rheumatoid Finger-Joint Function: Interim Report on Trial of Prosthetic Replacement , 1961 .

[34]  J. Bokros,et al.  Carbon biomedical devices , 1977 .

[35]  J. Kent,et al.  Quantitative histologic evaluation of LTI carbon, carbon-coated aluminum oxide and uncoated aluminum oxide dental implants. , 1983, Journal of Biomedical Materials Research.

[36]  M. Minami,et al.  Alumina ceramic prosthesis arthroplasty of the metacarpophalangeal joint in the rheumatoid hand. A 2-4-year follow-up study. , 1988, The Journal of arthroplasty.

[37]  D. Beevers,et al.  Metacarpophalangeal Joint Prostheses , 1995, Journal of hand surgery.

[38]  D. Kirschenbaum,et al.  Arthroplasty of the metacarpophalangeal joints with use of silicone-rubber implants in patients who have rheumatoid arthritis. Long-term results. , 1993, The Journal of bone and joint surgery. American volume.

[39]  A. Swanson Implant arthroplasty in the hand and upper extremity and its future. , 1981, The Surgical clinics of North America.

[40]  R. Beckenbaugh Preliminary experience with a noncemented nonconstrained total joint arthroplasty for the metacarpophalangeal joints. , 1983, Orthopedics.

[41]  L. Cocchiarella,et al.  Guides to the evaluation of permanent impairment , 2000 .