A Review of Power Quality Monitor Placement Methods in Transmission and Distribution Systems

In today's modern world, customers require a high level of power quality than ever before because of the increasing availability of semiconductor devices and microprocessors that are more sensitive against power system disturbances. One of the most frequently occurring types of power quality disturbances are voltage sags, which are considered to likely have a severe impact on sensitive load. Thus, power quality monitors (PQM) are required to be installed in many buses in a power system to assess disturbances such as voltage sags. However, the installation of PQMs at all buses considered in the system is uneconomical. Generally, PQM placement comprises four main methods, namely, monitor reach area, covering and packing, graph theory, and multivariable regression. This paper presents a comprehensive review of articles that deal with various methods of PQM placement. The concepts as well as the advantages and disadvantages of these methods are discussed and tabulated for an all-exclusive review. Although this paper does not show a comparison of numerical performance, most of the research publications on the subject of PQM placement methods are sorted and appended for easy reference. This work may be considered as an important guide for researchers who are interested in knowing and developing better PQM placement methods. Streszczenie. W artykule przedstawiono przegląd dotychczasowych prac dotyczących określenia lokalizacji montazu urządzen do monitoringu jakości energii w sieci. Omowiono idee dzialania, wady i zalety kazdej z metod. Nie dokonano porownania zlozoności obliczeniowej. Niniejsza praca stanowi przewodnik dla badaczy pracujących z tego typu urządzeniami. (Przegląd sposobow lokalizacji punktow monitorowania jakości energii w systemach przesylu i wytwarzania energii elektrycznej).

[1]  B.K. Duncan,et al.  Protection, metering, monitoring, and control of medium-voltage power systems , 2004, IEEE Transactions on Industry Applications.

[2]  J. V. Milanovic,et al.  On improvement of accuracy of optimal voltage sag monitoring programmes , 2010, Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010.

[3]  Hussain Shareef,et al.  A method for real power transfer allocation using multivariable regression analysis , 2012 .

[4]  Irene Yu-Hua Gu,et al.  Signal processing of power quality disturbances , 2006 .

[5]  Alessandro Ferrero,et al.  A distributed system for electric power quality measurement , 2002, IEEE Trans. Instrum. Meas..

[6]  Seung-Il Moon,et al.  Topological Locating of Power Quality Event Source , 2006 .

[7]  H. Shareef,et al.  Optimal placement of voltage sag monitors based on monitor reach area and sag severity index , 2010, 2010 IEEE Student Conference on Research and Development (SCOReD).

[8]  M. Eldery A novel power quality monitoring allocation algorithm , 2006, 2006 IEEE Power Engineering Society General Meeting.

[9]  Cai Wei,et al.  A study on optimal placement of voltage sag monitors , 2010, CICED 2010 Proceedings.

[10]  Math Bollen,et al.  Stochastic assessment of unbalanced voltage dips in large transmission systems , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[11]  Hussain Shareef,et al.  An Improved Power Quality Monitor Placement Method Using MVR Model and Combine Cp and Rp Statistical Indices , 2012 .

[12]  G. W. Stagg,et al.  Computer methods in power system analysis , 1968 .

[13]  J.V. Milanovic,et al.  Load modeling for voltage sag studies , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[14]  P.F. Ribeiro,et al.  Transmission systems power quality monitors allocation , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[15]  Il-Yop Chung,et al.  Development of power quality monitoring system with central processing scheme , 2002, IEEE Power Engineering Society Summer Meeting,.

[16]  M.H.J. Bollen,et al.  Effect of induction motors and other loads on voltage dips: theory and measurements , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[17]  Seon-Ju Ahn,et al.  Determination of the relative location of voltage sag source according to event cause , 2004, IEEE Power Engineering Society General Meeting, 2004..

[18]  H. Shareef,et al.  A novel PQM placement method using Cp and Rp statistical indices for power transmission and distribution networks , 2012, 2012 IEEE International Power Engineering and Optimization Conference Melaka, Malaysia.

[19]  Azah Mohamed,et al.  Tracking the Voltage Sag Source Location Using Multivariable Regression Model , 2011 .

[20]  Elisa Espinosa-Juarez,et al.  Neural Networks Applied to Solve the Voltage Sag State Estimation Problem: An Approach Based on the Fault Positions Concept , 2009, 2009 Electronics, Robotics and Automotive Mechanics Conference (CERMA).

[21]  M.H.J. Bollen,et al.  An optimal monitoring program for obtaining Voltage sag system indexes , 2006, IEEE Transactions on Power Systems.

[22]  C. F. M. Almeida,et al.  Allocation of Power Quality Monitors by Genetic Algorithms and Fuzzy Sets Theory , 2009, 2009 15th International Conference on Intelligent System Applications to Power Systems.

[23]  R. Schnorr von Carolsfeld,et al.  Using distributed power quality monitoring for better electrical system management , 1998, Conference Record of 1998 Annual Pulp and Paper Industry Technical Conference (Cat. No.98CH36219).

[24]  J.A. Martinez,et al.  Voltage sag studies in distribution Networks-part I: system modeling , 2006, IEEE Transactions on Power Delivery.

[25]  IEEE Power Engineering Society General Meeting , 2007, 2007 IEEE Power Engineering Society General Meeting.

[26]  Seon-Ju Ahn,et al.  A method to determine the relative location of voltage sag source for PQ , 2005, 2005 International Conference on Electrical Machines and Systems.

[27]  Math Bollen,et al.  Optimal dips monitoring program for characterization of transmission system , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[28]  Hussain Shareef,et al.  A new method for determining voltage sag source locations by using multivariable regression coefficients , 2011 .

[29]  Giovanni Bucci,et al.  A distributed measurement architecture for industrial applications , 2003, IEEE Trans. Instrum. Meas..

[30]  N. Kuzjurin Combinatorial Problems of Packing and Covering and Related Problems of Integer Linear Programming , 2002 .

[31]  Mark Allen Weiss,et al.  Data structures and problem solving using Java , 1997, SIGA.

[32]  E. Farjah,et al.  Optimal placement of monitors in transmission systems using fuzzy boundaries for voltage sag assessment , 2009, 2009 IEEE Bucharest PowerTech.

[33]  Azah Mohamed,et al.  A New Power Quality Monitor Placement Method Using the Multivariable Regression Model and Statistical Indices , 2011 .

[34]  G. Olguin An Optimal Trade-off between Monitoring and Simulation for Voltage Dip Characterization of Transmission Systems , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[35]  H.A. Abyaneh,et al.  A New Optimal Meter Placement Method for Obtaining a Transmission System Indices , 2007, 2007 IEEE Lausanne Power Tech.

[36]  H. Shareef,et al.  Optimal power quality monitor placement in power systems based on particle swarm optimization and artificial immune system , 2011, 2011 3rd Conference on Data Mining and Optimization (DMO).

[37]  Mark McGranaghan,et al.  Trends in Power Quality Monitoring P , 2001 .

[38]  Giovanni Bucci,et al.  Digital measurement station for power quality analysis in distributed environments , 2003, IEEE Trans. Instrum. Meas..

[39]  Seung-Il Moon,et al.  Optimal number and locations of power quality monitors considering system topology , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[40]  Jong-Woong Choe,et al.  A new algorithm to locate power-quality event source with improved realization of distributed monitoring scheme , 2006, IEEE Transactions on Power Delivery.