Open-Delta Three-Phase Inverter Current Control Using Predictive Control For PV System Connected To The Grid

Abstract. Predictive control method has advantages such as simple structure, functional and follow the simple mathematical. In this paper, a new method is provided for controlling the open-Delta three-phase inverter . Model-based predictive control system is used for controlling the current of a open-Delta three-phase inverter, which is in the process of converting the photovoltaic energy conversion plays a three-phase network. The controller at any time, the next period current are estimated using a model system. Four switches are used to build a open-delta three-phase inverter, that Four signal switches are necessary for inverter and Signals can be done based on the cost function minimization. Open-Delta Three-phase inverter, produces four pulses required to conduct two basic switching using switching PWM. Appropriate choice of switching states and estimated future states of the phase currents, the inverter may be provided with reasonable accuracy the phase currents. In this study the effect of different parameters such as: inductance coupling inductors, capacitors and reference current is evaluated on the performance of the proposed controller. A sample of inverters, with nominal power 3300 VA is simulated by SIMULINK MATLAB software.  At the simulation section of  paper, An example of the current predictive controller is designed for Open-Delta three-phase inverter , and is implemented in SIMULINK MATLAB software. The current predictive controller for the six-switch three-phase inverter is designed and implemented in SIMULINK MATLAB software and simulation results have been compared both three-phase inverter topology .

[1]  E.F. El-Saadany,et al.  Robust High Bandwidth Discrete-Time Predictive Current Control with Predictive Internal Model—A Unified Approach for Voltage-Source PWM Converters , 2008, IEEE Transactions on Power Electronics.

[2]  Liuchen Chang,et al.  An Advanced SVPWM-Based Predictive Current Controller for Three-Phase Inverters in Distributed Generation Systems , 2008, IEEE Transactions on Industrial Electronics.

[3]  A. Keyhani,et al.  Control of distributed generation systems-Part I: Voltages and currents control , 2004, IEEE Transactions on Power Electronics.

[4]  Frede Blaabjerg,et al.  A new optimized space-vector modulation strategy for a component-minimized voltage source inverter , 1997 .

[5]  Paolo Mattavelli,et al.  An improved deadbeat control for UPS using disturbance observers , 2005, IEEE Transactions on Industrial Electronics.

[6]  E.F. El-Saadany,et al.  Adaptive Discrete-Time Grid-Voltage Sensorless Interfacing Scheme for Grid-Connected DG-Inverters Based on Neural-Network Identification and Deadbeat Current Regulation , 2008, IEEE Transactions on Power Electronics.

[7]  Poh Chiang Loh,et al.  An improved robust predictive current regulation algorithm , 2005, IEEE Transactions on Industry Applications.

[8]  S. Buso,et al.  Robust dead-beat current control for PWM rectifiers and active filters , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[9]  A. Nasiri Digital Control of Three-Phase Series-Parallel Uninterruptible Power Supply Systems , 2007, IEEE Transactions on Power Electronics.

[10]  Paolo Mattavelli,et al.  Uninterruptible power supply multiloop control employing digital predictive voltage and current regulators , 2001 .

[11]  Jiang Li,et al.  Flux vector modulation strategy for a four-switch three-phase inverter for motor drive applications , 1997, PESC97. Record 28th Annual IEEE Power Electronics Specialists Conference. Formerly Power Conditioning Specialists Conference 1970-71. Power Processing and Electronic Specialists Conference 1972.

[12]  T. Undeland,et al.  Stationary frame voltage harmonic controller for standalone power generation , 2007, 2007 European Conference on Power Electronics and Applications.

[13]  Paolo Mattavelli,et al.  An Adaptive Control for UPS to Compensate Unbalance and Harmonic Distortion Using a Combined Capacitor/Load Current Sensing , 2007, IEEE Transactions on Industrial Electronics.

[14]  A.M.N. Lima,et al.  AC/AC converter with four switch three phase structures , 1996, PESC Record. 27th Annual IEEE Power Electronics Specialists Conference.

[15]  Paolo Mattavelli,et al.  Repetitive-Based Controller for a UPS Inverter to Compensate Unbalance and Harmonic Distortion , 2007, IEEE Transactions on Industrial Electronics.

[16]  Thomas A. Lipo,et al.  VSI-PWM rectifier/inverter system with a reduced switch count , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[17]  Y. Kawabata,et al.  Novel vector control system using deadbeat controlled PWM inverter with output LC filter , 2002, Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344).

[18]  W. Mcmurray,et al.  Modulation of the Chopping Frequency in DC Choppers and PWM Inverters Having Current-Hysteresis Controllers , 1983, IEEE Transactions on Industry Applications.

[19]  Ehab F. El-Saadany,et al.  An Improved Deadbeat Current Control Scheme With a Novel Adaptive Self-Tuning Load Model for a Three-Phase PWM Voltage-Source Inverter , 2007, IEEE Transactions on Industrial Electronics.

[20]  Jacobus Daniel van Wyk,et al.  A Comparative Investigation of a Three-Phase Induction Machine Drive with a Component Minimized Voltage-Fed Inverter under Different Control Options , 1984 .

[21]  Frede Blaabjerg,et al.  Adaptive SVM to compensate DC-link voltage ripple for four-switch three-phase voltage-source inverters , 1999 .

[22]  F. Blaabjerg,et al.  Comparison of a Space-Vector Modulation Strategy for a Three Phase Standard and a Component Minimized Voltage Source Inverter , 1995 .

[23]  Osman Kukrer,et al.  Deadbeat control of a three-phase inverter with an output LC filter , 1996 .

[24]  Sheng-Ming Yang,et al.  A deadbeat current controller for field oriented induction motor drives , 2002 .

[25]  P. Mattavelli,et al.  Predictive digital control of power factor preregulators with input voltage estimation using disturbance observers , 2005, IEEE Transactions on Power Electronics.

[26]  Frede Blaabjerg,et al.  A new optimized space vector modulation strategy for a component minimized voltage source inverter , 1995, Proceedings of 1995 IEEE Applied Power Electronics Conference and Exposition - APEC'95.

[27]  Poh Chiang Loh,et al.  Analysis of multiloop control strategies for LC/CL/LCL-filtered voltage-source and current-source inverters , 2005, IEEE Transactions on Industry Applications.

[28]  Poh Chiang Loh,et al.  A comparative analysis of multiloop voltage regulation strategies for single and three-phase UPS systems , 2003 .