Comparative Testing of a Miniature Diffusion Size Classifier to Assess Airborne Ultrafine Particles Under Field Conditions

Miniature diffusion size classifiers (miniDiSC) are novel handheld devices to measure ultrafine particles (UFP). UFP have been linked to the development of cardiovascular and pulmonary diseases; thus, detection and quantification of these particles are important for evaluating their potential health hazards. As part of the UFP exposure assessments of highway maintenance workers in western Switzerland, we compared a miniDiSC with a portable condensation particle counter (P-TRAK). In addition, we performed stationary measurements with a miniDiSC and a scanning mobility particle sizer (SMPS) at a site immediately adjacent to a highway. Measurements with miniDiSC and P-TRAK correlated well (correlation of r = 0.84) but average particle numbers of the miniDiSC were 30%–60% higher. This difference was significantly increased for mean particle diameters below 40 nm. The correlation between the miniDiSC and the SMPS during stationary measurements was very high (r = 0.98) although particle numbers from the miniDiSC were 30% lower. Differences between the three devices were attributed to the different cutoff diameters for detection. Correction for this size dependent effect led to very similar results across all counters. We did not observe any significant influence of other particle characteristics. Our results suggest that the miniDiSC provides accurate particle number concentrations and geometric mean diameters at traffic-influenced sites, making it a useful tool for personal exposure assessment in such settings. Copyright 2012 American Association for Aerosol Research

[1]  A. Peters,et al.  Particulate Matter Air Pollution and Cardiovascular Disease: An Update to the Scientific Statement From the American Heart Association , 2010, Circulation.

[2]  Joel Schwartz,et al.  REVIEW OF EPIDEMIOLOGICAL EVIDENCE OF HEALTH EFFECTS OF PARTICULATE AIR POLLUTION , 1995 .

[3]  A. Peters,et al.  Lessons From Air Pollution Epidemiology for Studies of Engineered Nanomaterials , 2011, Journal of occupational and environmental medicine.

[4]  Alireza Afshari,et al.  Measurement of Ultrafine Particles: A Comparison of Two Handheld Condensation Particle Counters , 2004 .

[5]  H. Schulz,et al.  Dosimetry and toxicology of inhaled ultrafine particles , 2009, Biomarkers : biochemical indicators of exposure, response, and susceptibility to chemicals.

[6]  A. Peters,et al.  Exposure to traffic and the onset of myocardial infarction. , 2004, The New England journal of medicine.

[7]  Yifang Zhu,et al.  Field Comparison of P-Trak and Condensation Particle Counters , 2006 .

[8]  Heinz Burtscher,et al.  Design, Calibration, and Field Performance of a Miniature Diffusion Size Classifier , 2011 .

[9]  Ronald W Williams,et al.  Cardiovascular effects in patrol officers are associated with fine particulate matter from brake wear and engine emissions , 2004, Particle and Fibre Toxicology.

[10]  Wojciech Zareba,et al.  Changes in deceleration capacity of heart rate and heart rate variability induced by ambient air pollution in individuals with coronary artery disease , 2010, Particle and Fibre Toxicology.

[11]  David B. Kittelson,et al.  Measurement of Electrical Charge on Diesel Particles , 2005 .

[12]  Eero Antikainen,et al.  Particle Emissions from a Small Two-Stroke Engine: Effects of Fuel, Lubricating Oil, and Exhaust Aftertreatment on Particle Characteristics , 2005 .