Fault-Location Algorithms Without Utilizing Line Parameters Based on the Distributed Parameter Line Model

This paper presents novel power system transmission-line fault-location algorithms without requiring transmission-line parameters. The voltages and currents from both ends of a line are taken as inputs and no synchronization is required. Both prefault and fault data may be utilized. The proposed methods are based on a distributed parameter line model and, hence, fully consider the impacts of shunt capacitance of the line. Positive-sequence line parameters may also be estimated as a byproduct. No assumption on the source impedance and fault resistance is made. Evaluation studies based on Electromagnetic Transients Program (EMTP) simulation data demonstrate that the new methods are able to achieve quite accurate estimates.

[1]  S. Elangovan,et al.  Unsynchronised two-terminal transmission-line fault-location without using line parameters , 2006 .

[2]  A. T. Johns,et al.  New technique for the accurate location of earth faults on transmission systems , 1995 .

[3]  D. J. Lawrence,et al.  Development of an advanced transmission line fault location system. II. Algorithm development and simulation , 1992 .

[4]  M. Saha,et al.  An Accurate Fault Locator With Compensation For Apparent Reactance In The Fault Resistance Resulting From Remore-End Infeed , 1985, IEEE Transactions on Power Apparatus and Systems.

[5]  Yuan Liao,et al.  Optimal Estimate of Transmission Line Fault Location Considering Measurement Errors , 2007, IEEE Transactions on Power Delivery.

[6]  J. Izykowski,et al.  Accurate location of faults on power transmission lines with use of two-end unsynchronized measurements , 2006, IEEE Transactions on Power Delivery.

[7]  J. A. Jiang,et al.  A New Adaptive PMU-Based Protection Scheme for Transposed/Untransposed Parallel Transmission Lines , 2002, IEEE Power Engineering Review.

[8]  M. S. Sachdev,et al.  A technique for estimating transmission line fault locations from digital impedance relay measurements , 1988 .

[9]  Adly A. Girgis,et al.  A new fault location technique for two- and three-terminal lines , 1992 .

[10]  A.A. Girgis,et al.  Fault location on a transmission line using synchronized Voltage measurements , 2004, IEEE Transactions on Power Delivery.

[11]  Mladen Kezunovic,et al.  Locating faults in the transmission network using sparse field measurements, simulation data and genetic algorithm , 2004 .

[12]  Gary W. Chang,et al.  Power System Analysis , 1994 .