Quantitative head ultrasound measurements to determine thresholds for preterm neonates requiring interventional therapies following intraventricular hemorrhage

Dilation of the cerebral ventricles is a common condition in preterm neonates with intraventricular hemorrhage (IVH). This post hemorrhagic ventricle dilation (PHVD) can lead to lifelong neurological impairment through ischemic injury due to increased intracranial pressure and without treatment, can lead to death. Clinically, 2D ultrasound (US) through the fontanelles ('soft spots') of the patients are serially acquired to monitor the progression of the ventricle dilation. These images are used to determine when interventional therapies such as needle aspiration of the built up cerebrospinal fluid (CSF) ('ventricle tap', VT) might be indicated for a patient; however, quantitative measurements of the growth of the ventricles are often not performed. There is no consensus on when a neonate with PHVD should have an intervention and often interventions are performed after the potential for brain damage is quite high. Previously we have developed and validated a 3D US system to monitor the progression of ventricle volumes (VV) in IVH patients. We will describe the potential utility of quantitative 2D and 3D US to monitor and manage PHVD in neonates. Specifically, we will look to determine image-based measurement thresholds for patients who will require VT in comparison to patients with PHVD who resolve without intervention. Additionally, since many patients who have an initial VT will require subsequent interventions, we look at the potential for US to determine which PHVD patients will require additional VT after the initial one has been performed.

[1]  L. Papile,et al.  Quantification of neonatal cerebral ventricular volume by real‐time ultrasonography. In vivo validation of the cylindrical coordinate method. , 1990, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[2]  Donal B. Downey,et al.  Three-dimensional ultrasound imaging , 1995, Medical Imaging.

[3]  N. Nagdyman,et al.  3-D ultrasound quantification of neonatal cerebral ventricles in different head positions. , 1999, Ultrasound in medicine & biology.

[4]  M W Davies,et al.  Reference ranges for the linear dimensions of the intracranial ventricles in preterm neonates , 2000, Archives of disease in childhood. Fetal and neonatal edition.

[5]  H C Charles,et al.  Infant cerebral ventricle volume: a comparison of 3-D ultrasound and magnetic resonance imaging. , 2001, Ultrasound in medicine & biology.

[6]  A. Synnes,et al.  Variations in intraventricular hemorrhage incidence rates among Canadian neonatal intensive care units. , 2001, The Journal of pediatrics.

[7]  L J Horwood,et al.  Posthaemorrhagic ventricular dilatation in the premature infant: natural history and predictors of outcome , 2002, Archives of disease in childhood. Fetal and neonatal edition.

[8]  Mariko Momoi,et al.  Cerebral ventricular volume assessment by three-dimensional ultrasonography , 2005, Journal of perinatal medicine.

[9]  Angelika Berger,et al.  3-D ultrasonographic imaging of the cerebral ventricular system in very low birth weight infants. , 2005, Ultrasound in medicine & biology.

[10]  Andrew Whitelaw,et al.  Management of posthaemorrhagic ventricular dilatation , 2011, Archives of Disease in Childhood: Fetal and Neonatal Edition.

[11]  Sergio A Ajzen,et al.  Fetal cerebral ventricle volumetry: comparison between 3D ultrasound and magnetic resonance imaging in fetuses with ventriculomegaly , 2011, The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians.

[12]  A Fenster,et al.  3D ultrasound system to investigate intraventricular hemorrhage in preterm neonates , 2013, Physics in Medicine and Biology.

[13]  Aaron Fenster,et al.  In vivo validation of a 3D ultrasound system for imaging the lateral ventricles of neonates , 2014, Medical Imaging.

[14]  Aaron Fenster,et al.  User-guided segmentation of preterm neonate ventricular system from 3-D ultrasound images using convex optimization. , 2015, Ultrasound in medicine & biology.

[15]  Aaron Fenster,et al.  In Vivo Validation of a 3-D Ultrasound System for Imaging the Lateral Ventricles of Neonates. , 2016, Ultrasound in medicine & biology.