A temporal method of avoiding the Cerenkov radiation generated in organic scintillator dosimeters by pulsed mega-voltage electron and photon beams.

The output signal of an organic scintillator probe consists of a scintillation signal and Cerenkov and fluorescence radiation (CFR) signal when the probe is exposed to a mega-voltage photon or electron beam. The CFR signal is usually unwanted because it comes from both the scintillator and light guide and so it is not proportional to the absorbed dose in the scintillator. A new organic scintillator detector system has been constructed for absorbed dose measurement in pulsed mega-voltage electron and photon beams that are commonly used in radiotherapy treatment, eliminating most of the CFR signal. The new detector system uses a long decay constant BC-444G (Bicron, Newbury, OH, USA) scintillator which gives a signal that can be time resolved from the prompt CFR signal so that the measured contribution of prompt signal is negligible. The response of the new scintillator detector system was compared with the measurements from a plastic scintillator detector that were corrected for the signal contribution from the CFR, and to appropriately corrected ion chamber measurements showing agreement in the 16 MeV electron beam used.

[1]  R. Schmidt-Ullrich,et al.  Radiation-induced light in optical fibers and plastic scintillators: application to brachytherapy dosimetry , 1996 .

[2]  Thomas R. Mackie,et al.  Cerenkov light generated in optical fibres and other light pipes irradiated by electron beams , 1992 .

[3]  R A Sutton,et al.  Water equivalence of plastic organic scintillators in megavoltage radiotherapy bremsstrahlung beams. , 2000, Physics in medicine and biology.

[4]  M R McEwen,et al.  Ion recombination corrections for the NACP parallel-plate chamber in a pulsed electron beam. , 1998, Physics in medicine and biology.

[5]  F. H. Attix,et al.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements. , 1992, Physics in medicine and biology.

[6]  Leon S. Lasdon,et al.  Design and Testing of a Generalized Reduced Gradient Code for Nonlinear Programming , 1978, TOMS.

[7]  J. W. Boag,et al.  Ionization Measurements at Very High Intensities—Part I , 1950 .

[8]  A Piermattei,et al.  The saturation loss for plane parallel ionization chambers at high dose per pulse values. , 2000, Physics in medicine and biology.

[9]  A. Nahum,et al.  The IPEMB code of practice for electron dosimetry for radiotherapy beams of initial energy from 2 to 50 MeV based on an air kerma calibration. Institution of Physics and Engineering in Medicine and Biology. , 1996, Physics in medicine and biology.

[10]  A. Swallow Book Review: The dosimetry of pulsed radiation. ICRU Report 34, International Commission on Radiation Units and Measurements, Bethesda, Maryland, 1982, pp. vii + 47. , 1984 .

[11]  P. L. Mattern,et al.  Absorption Induced in Optical Waveguides by Pulsed Electrons as a Function of Temperature, Low Dose Rate Gamma and Beta Rays, and 14 MeV Neutrons , 1975, IEEE Transactions on Nuclear Science.

[12]  P. B. Lyons,et al.  Transient Radiation Effects in Low-Loss Optical Waveguides , 1977, IEEE Transactions on Nuclear Science.

[13]  A. Savitzky,et al.  Smoothing and Differentiation of Data by Simplified Least Squares Procedures. , 1964 .

[14]  Aapm A protocol for the determination of absorbed dose from high-energy photon and electron beams. , 1983, Medical physics.

[15]  J W Boag,et al.  Current collection and ionic recombination in small cylindrical ionization chambers exposed to pulsed radiation. , 1980, The British journal of radiology.

[16]  H. H. Madden Comments on the Savitzky-Golay convolution method for least-squares-fit smoothing and differentiation of digital data , 1976 .

[17]  A S Beddar,et al.  Optical filtering and spectral measurements of radiation-induced light in plastic scintillation dosimetry , 1993 .

[18]  D Flühs,et al.  Direct reading measurement of absorbed dose with plastic scintillators--the general concept and applications to ophthalmic plaque dosimetry. , 1996, Medical physics.

[19]  M. Clift,et al.  Dealing with Cerenkov radiation generated in organic scintillator dosimeters by bremsstrahlung beams. , 2000, Physics in medicine and biology.

[20]  F. H. Attix,et al.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration. , 1992, Physics in medicine and biology.

[21]  B. D. Evans,et al.  Permanent and transient radiation induced losses in optical fibers , 1974 .

[22]  L. M. Watkins,et al.  The effects of radiation on the absorption and luminescence of fiber optic waveguides and materials , 1974 .