Measurement and analysis of Vibrio Fischeri cell-based microfluidic device for personal health monitoring

The cell-based microfluidic chip was designed and fabricated as a low-cost detector to continuously monitor toxicants in drinking water or human urine samples, which is expected to be an important component of a household health monitoring system in the future. The bioluminescent bacterium, Vibrio Fischeri, was selected to validate the function of device. Water samples and Vibrio fischeri cells were mixed and encapsulated into droplets in air flow, which can guarantee sufficient oxygen supply for cells in droplets. Preliminary tests were performed using copper ion (Cu2+) as the model toxicant. The droplet system was measured and analyzed at various flow rates in different observation chambers. Both deionized water and human urine samples were tested in the cell-based device. Interestingly, a strong relation between the R.L.U. (Relative Luminescence Units) in the observation chamber and the minute concentration of toxicant (Cu2+) was found using deionized water as solvent, whereas the relation was insignificant using human urine as solvent. This study showed the Vibrio fischeri cell-based device might be reliably employed as an early-warning system for the safety of drinking water. However, Vibrio fischeri is not competent to detect dangerous mThe cell-based microfluidic chip was designed and fabricated as a low-cost detector to continuously monitor toxicants in drinking water or human urine samples, which is expected to be an important component of a household health monitoring system in the future. The bioluminescent bacterium, Vibrio Fischeri, was selected to validate the function of device. Water samples and Vibrio fischeri cells were mixed and encapsulated into droplets in air flow, which can guarantee sufficient oxygen supply for cells in droplets. Preliminary tests were performed using copper ion (Cu2+) as the model toxicant. The droplet system was measured and analyzed at various flow rates in different observation chambers. Both deionized water and human urine samples were tested in the cell-based device. Interestingly, a strong relation between the R.L.U. (Relative Luminescence Units) in the observation chamber and the minute concentration of toxicant (Cu2+) was found using deionized water as solvent, whereas the relation was insignificant using human urine as solvent. This study showed the Vibrio fischeri cell-based device might be reliably employed as an early-warning system for the safety of drinking water. However, Vibrio fischeri is not competent to detect dangerous materials in a complex biofluid. With the replacement of cell sensors, the microfluidic device might be functional to analyze urine samples in theory.aterials in a complex biofluid. With the replacement of cell sensors, the microfluidic device might be functional to analyze urine samples in theory.

[1]  Li Xie,et al.  Microelectronic cell sensor assay for detection of cytotoxicity and prediction of acute toxicity. , 2006, Toxicology in vitro : an international journal published in association with BIBRA.

[2]  Tao Dong,et al.  Design and optimization of non-clogging counter-flow microconcentrator for enriching epidermoid cervical carcinoma cells , 2011, Biomedical microdevices.

[3]  Adrian W. Müller,et al.  Detection of environmental pollutants using optical biosensor with immobilized algae cells , 1998 .

[4]  P. Marriott,et al.  A review of environmental toxicant analysis by using multidimensional gas chromatography and comprehensive GC. , 2003, Clinica chimica acta; international journal of clinical chemistry.

[5]  M. Truong,et al.  Toward the detection of prostate cancer in urine: a critical analysis. , 2013, The Journal of urology.

[6]  Shimshon Belkin,et al.  Microbial sensor cell arrays. , 2012, Current opinion in biotechnology.

[7]  Tao Dong,et al.  Freon R141b flow boiling in silicon microchannel heat sinks: experimental investigation , 2007 .

[8]  Miguel Rodriguez,et al.  Biosensors for rapid monitoring of primary-source drinking water using naturally occurring photosynthesis. , 2002, Biosensors & bioelectronics.

[9]  Xinyan Zhao,et al.  Multifunctional sample preparation kit and on-chip quantitative nucleic acid sequence-based amplification tests for microbial detection. , 2012, Analytical chemistry.

[10]  Nuno M. M. Pires,et al.  A mediator embedded micro-immunosensing unit for electrochemical detection on viruses within physiological saline media , 2011 .

[11]  Eirik Bentzen Egeland,et al.  Integratable non-clogging microconcentrator based on counter-flow principle for continuous enrichment of CaSki cells sample , 2011 .

[12]  Tao Dong,et al.  A smart fully integrated micromachined separator with soft magnetic micro-pillar arrays for cell isolation , 2010 .

[13]  Tao Dong,et al.  Integrated micro Pirani gauge based hermetical package monitoring for uncooled VOx bolometer FPAs , 2011 .

[14]  Chao Zhang,et al.  Construction and evaluation of two biosensors based on yeast transcriptional response to genotoxic chemicals. , 2013, Biosensors & bioelectronics.

[15]  I. Gitelson,et al.  A bioluminescent signal system: detection of chemical toxicants in water. , 2007, Luminescence : the journal of biological and chemical luminescence.

[16]  Tao Dong,et al.  Measurement and modeling of R141b condensation heat transfer in silicon rectangular microchannels , 2008 .

[17]  Zhaochu Yang,et al.  Compatible immuno-NASBA LOC device for quantitative detection of waterborne pathogens: design and validation. , 2012, Lab on a chip.

[18]  Tao Dong,et al.  Power generation from conductive droplet sliding on electret film , 2012 .

[19]  Zhaochu Yang,et al.  Molecular simulations of R141b boiling flow in micro/nano channel: Interfacial phenomena , 2006 .