Robust EPI Nyquist ghost elimination via spatial and temporal encoding

Nyquist ghosts are an inherent artifact in echo planar imaging acquisitions. An approach to robustly eliminate Nyquist ghosts is presented that integrates two previous Nyquist ghost correction techniques: temporal domain encoding (phase labeling for additional coordinate encoding: PLACE and spatial domain encoding (phased array ghost elimination: PAGE). Temporal encoding modulates the echo planar imaging acquisition trajectory from frame to frame, enabling one to interleave data to remove inconsistencies that occur between sampling on positive and negative gradient readouts. With PLACE, one can coherently combine the interleaved data to cancel residual Nyquist ghosts. If the level of ghosting varies significantly from image to image, however, the signal cancellation that occurs with PLACE can adversely affect SNR‐sensitive applications such as perfusion imaging with arterial spin labeling. This work proposes integrating PLACE into a PAGE‐based reconstruction process to yield significantly better Nyquist ghost correction that is more robust than PLACE or PAGE alone. The robustness of this method is demonstrated in the presence of magnetic field drift with an in‐vivo arterial spin labeling perfusion experiment. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.

[1]  J M Taveras,et al.  Magnetic Resonance in Medicine , 1991, The Western journal of medicine.

[2]  F H Epstein,et al.  Adaptive sensitivity encoding incorporating temporal filtering (TSENSE) † , 2001, Magnetic resonance in medicine.

[3]  D. Larkman,et al.  Parallel magnetic resonance imaging , 2007, Physics in medicine and biology.

[4]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[5]  C. Ahn,et al.  A New Phase Correction Method in NMR Imaging Based on Autocorrelation and Histogram Analysis , 1987, IEEE Transactions on Medical Imaging.

[6]  P. Bandettini,et al.  QUIPSS II with thin‐slice TI1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling , 1999, Magnetic resonance in medicine.

[7]  S G Kim,et al.  Perfusion imaging by a flow‐sensitive alternating inversion recovery (Fair) technique: Application to functional brain imaging , 1997, Magnetic resonance in medicine.

[8]  Jon-Fredrik Nielsen,et al.  Automatic correction of echo‐planar imaging (EPI) ghosting artifacts in real‐time interactive cardiac MRI using sensitivity encoding , 2008, Journal of magnetic resonance imaging : JMRI.

[9]  Huan Tan,et al.  Improved self-referenced parallel MRI imaging in EPI by using UNFOLD to remove Nyquist ghosts , 2009 .

[10]  Martin Blaimer,et al.  General formulation for quantitative G‐factor calculation in GRAPPA reconstructions , 2009, Magnetic resonance in medicine.

[11]  J. Pipe Motion correction with PROPELLER MRI: Application to head motion and free‐breathing cardiac imaging , 1999, Magnetic resonance in medicine.

[12]  H Bruder,et al.  Image reconstruction for echo planar imaging with nonequidistant k‐space sampling , 1992, Magnetic resonance in medicine.

[13]  R Turner,et al.  Real‐time movie imaging from a single cardiac cycle by NMR , 1987, Magnetic resonance in medicine.

[14]  D. Le Bihan,et al.  Double-sampled echo-planar imaging at 3 tesla. , 1996, Journal of magnetic resonance. Series B.

[15]  Peter Kellman,et al.  Phased array ghost elimination , 2006, NMR in biomedicine.

[16]  M H Buonocore,et al.  Image‐based ghost correction for interleaved EPI , 2001, Magnetic resonance in medicine.

[17]  J. H. Duyn,et al.  Multislice Imaging of Quantitative Cerebral Perfusion with Pulsed Arterial Spin-Labeling , 1998, NeuroImage.

[18]  E R McVeigh,et al.  Referenceless interleaved echo‐planar imaging , 1999, Magnetic resonance in medicine.

[19]  F. Ye,et al.  Correction for geometric distortion and N/2 ghosting in EPI by phase labeling for additional coordinate encoding (PLACE) , 2007, Magnetic resonance in medicine.

[20]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[21]  J Sijbers,et al.  Estimation of the noise in magnitude MR images. , 1998, Magnetic resonance imaging.

[22]  William Scott Hoge,et al.  A subspace identification extension to the phase correlation method [MRI application] , 2003, IEEE Transactions on Medical Imaging.

[23]  Nan-kuei Chen,et al.  Removal of EPI Nyquist ghost artifacts with two‐dimensional phase correction , 2004, Magnetic resonance in medicine.

[24]  Walter F Block,et al.  Characterizing and correcting gradient errors in non‐cartesian imaging: Are gradient errors linear time‐invariant (LTI)? , 2009, Magnetic resonance in medicine.