Numerical analysis of a shell-and-tube latent heat storage unit with fins for air-conditioning application

Free cooling is an effective way to make good use of night cold energy and helps to reduce air-conditioning energy consumption in the daytime. This research proposed integrating a new-type of shell-and-tube based phase change material (PCM) thermal storage system with conventional air-conditioner to increase cooling coefficient of performance (COP). The proposed PCM thermal storage unit uses two different kinds of media (water and air) for the heat transfer fluids (HTF). Water is used for charging loop while air is used for discharging loop. The two HTFs better fit the heat transfer needs of nighttime’s free cooling harvest and daytime’s condensing water use by the air-conditioning system. A numerical model for the PCM thermal storage unit has been developed, particularly with consideration of staged natural convection effects in PCM melting process. The numerical model equipped with a new PCM staged effective thermal conductivity has been validated by experimental data. Numerical study has evaluated the effects of HTF inlet temperature, mass flow rate and conductive fin height on the PCM thermal storage system’s performance. Modeling results show that HTF mass flow rate and fin height need to be designed through an optimization process according to the cooling load profile and achieve best performance of the PCM thermal storage system. Effectiveness of this proposed PCM thermal storage system is generally higher than 0.5. Case study of replacing conventional cooling tower by the proposed PCM thermal storage system for a water-cooled air-conditioner shows a COP value increase of about 25.6%.

[1]  X. Py,et al.  Highly conductive composites made of phase change materials and graphite for thermal storage , 2008 .

[2]  Eduardo Zarza,et al.  Analysis of the experimental behaviour of a 100 kWth latent heat storage system for direct steam generation in solar thermal power plants , 2010 .

[3]  Zia Ud Din,et al.  Phase change material (PCM) storage for free cooling of buildings—A review , 2013 .

[4]  Changying Zhao,et al.  A numerical investigation of heat transfer in phase change materials (PCMs) embedded in porous metals , 2011 .

[5]  Saiful Bari,et al.  Waste heat recovery from a diesel engine using shell and tube heat exchanger , 2013 .

[6]  T. L. Bergman,et al.  High temperature latent heat thermal energy storage using heat pipes , 2010 .

[7]  Mark Modera,et al.  Swimming pools as heat sinks for air conditioners: Model design and experimental validation for natural thermal behavior of the pool , 2011 .

[8]  M. Farid,et al.  An electrical storage heater using the phase-change method of heat storage , 1990 .

[9]  Zhenyu Liu,et al.  Numerical modeling for solid–liquid phase change phenomena in porous media: Shell-and-tube type latent heat thermal energy storage , 2013 .

[10]  V. Selladurai,et al.  Experimental analysis of a new refrigerant mixture as drop-in replacement for CFC12 and HFC134a , 2008 .

[11]  Mark Modera,et al.  Swimming pools as heat sinks for air conditioners: California feasibility analysis , 2013 .

[12]  Francis W.H. Yik,et al.  Modeling the performance characteristics of water-cooled air-conditioners , 2008 .

[13]  Hongfa Di,et al.  Application of latent heat thermal energy storage in buildings: State-of-the-art and outlook , 2007 .

[14]  W. L. Lee,et al.  Applying water cooled air conditioners in residential buildings in Hong Kong , 2008 .

[15]  Francis Agyenim,et al.  A review of materials, heat transfer and phase change problem formulation for latent heat thermal energy storage systems (LHTESS) , 2010 .

[16]  Bin-Juine Huang,et al.  Study of a high efficiency residential split water-cooled air conditioner , 2005 .

[17]  Nasrudin Abd Rahim,et al.  Review of PCM based cooling technologies for buildings , 2012 .

[18]  Hansjürg Leibundgut,et al.  Stuck in a stack—Temperature measurements of the microclimate around split type condensing units in a high rise building in Singapore , 2014 .

[19]  Kamil Kaygusuz,et al.  Thermal energy storage performance of paraffin in a novel tube-in-shell system , 2008 .

[20]  Abdollah Avara,et al.  Optimum placement of condensing units of split-type air-conditioners by numerical simulation , 2008 .

[21]  Patrick E. Phelan,et al.  Feasibility of lowering the condenser's inlet water temperature of a chiller using thermal water storage , 2000 .

[22]  Yvan Dutil,et al.  A review on phase-change materials: Mathematical modeling and simulations , 2011 .

[23]  B. Nedjar,et al.  An enthalpy-based finite element method for nonlinear heat problems involving phase change , 2002 .

[24]  R. Velraj,et al.  Heat transfer and pressure drop studies on a PCM-heat exchanger module for free cooling applications , 2011 .

[25]  Liang-Bi Wang,et al.  Numerical study of the heat charging and discharging characteristics of a shell-and-tube phase change heat storage unit , 2013 .

[26]  Mervyn Smyth,et al.  A comparison of heat transfer enhancement in a medium temperature thermal energy storage heat exchanger using fins , 2009 .

[27]  Yuehong Su,et al.  Experimental investigation on PCM cold storage integrated with ejector cooling system , 2014 .

[28]  S. M. Shiva Nagendra,et al.  Passive alternatives to mechanical air conditioning of building: A review , 2013 .

[29]  Jiang Yi,et al.  Modeling and experimental study on an innovative passive cooling system—NVP system , 2003 .

[30]  Zhanhua Ma,et al.  Solid velocity correction schemes for a temperature transforming model for convection phase change , 2006 .

[31]  Donal Finn,et al.  Mathematical modeling of a low temperature low approach direct cooling tower for the provision of high temperature chilled water for conditioning of building spaces , 2014 .

[32]  Anica Trp,et al.  An experimental and numerical investigation of heat transfer during technical grade paraffin melting and solidification in a shell-and-tube latent thermal energy storage unit , 2005 .

[33]  V. Voller FAST IMPLICIT FINITE-DIFFERENCE METHOD FOR THE ANALYSIS OF PHASE CHANGE PROBLEMS , 1990 .

[34]  Ya-Ling He,et al.  Numerical study on thermal energy storage performance of phase change material under non-steady-state inlet boundary , 2011 .

[35]  Craig P. Wray,et al.  The effects of roof reflectance on air temperatures surrounding a rooftop condensing unit , 2008 .

[36]  Hamid Ait Adine,et al.  Numerical analysis of the thermal behaviour of a shell-and-tube heat storage unit using phase change materials , 2009 .

[37]  Per Heiselberg,et al.  Review of thermal energy storage technologies based on PCM application in buildings , 2013 .

[38]  Martin Belusko,et al.  Maximisation of heat transfer in a coil in tank PCM cold storage system , 2011 .

[39]  Luisa F. Cabeza,et al.  Experimental analysis of the effectiveness of a high temperature thermal storage tank for solar cooling applications , 2013 .

[40]  Ciro Aprea,et al.  Numerical analysis of an air condenser working with the refrigerant fluid R407C , 2007 .

[41]  Dongsoo Jung,et al.  Performance of R290 and R1270 for R22 applications with evaporator and condenser temperature variation , 2008 .

[42]  Luisa F. Cabeza,et al.  Building integration of PCM for natural cooling of buildings , 2013 .

[43]  K. Sopian,et al.  Internal and external fin heat transfer enhancement technique for latent heat thermal energy storage in triplex tube heat exchangers , 2013 .

[44]  J. Payá,et al.  Performance characterization of a PCM storage tank , 2014 .