Reliability of clinical nerve function assessment in peripheral neuropathies.

INTRODUCTION Sensory and/or motor nerve function impairment as a consequence of neuropathy is often assessed using electroneurophysiological tests. However, in low-resource countries where the required equipment is rarely available, manual muscle strength testing (MMST) and monofilament testing (MFT) offer very reliable alternatives. In six leprosy programmes in four Asian countries, a multi-centre randomised clinical trial (RCT) was carried out to assess the effect of corticosteroids on neuropathy in leprosy-affected people. The sensory and motor nerve function was tested using MMST and MFT, including new test sites for the sural and radial cutaneous nerves (MFT) and the posterior tibial and common peroneal nerves (MMST). The reliability studies of the MMST and MFT tests of the TENLEP (Treatment of Early Neuropathy in LEProsy) trials are presented here. METHODS Two assessors in each centre independently used the MFT and MMST in 30 leprosy-affected people. RESULTS Reliability is good to very good for MFT in nearly all nerves. MMST also shows good to very good agreement, with a few exceptions. CONCLUSION Our study confirms that MMST and MFT can be performed reliably, and that the new tests also have acceptable reliability.

[1]  D. Lockwood,et al.  Two randomized controlled clinical trials to study the effectiveness of prednisolone treatment in preventing and restoring clinical nerve function loss in leprosy: the TENLEP study protocols , 2012, BMC Neurology.

[2]  R. Wexler,et al.  Dorsal sensory impairment in hands and feet of people affected by Hansen's disease in Israel. , 2007, Leprosy review.

[3]  W. V. van Brakel,et al.  Ensuring inter-tester reliability of voluntary muscle and monofilament sensory testing in the INFIR Cohort Study. , 2007, Leprosy review.

[4]  H. Stam,et al.  The Intrinsic Muscles of the Hand , 2007 .

[5]  D. Lockwood,et al.  The INFIR Cohort Study: investigating prediction, detection and pathogenesis of neuropathy and reactions in leprosy. Methods and baseline results of a cohort of multibacillary leprosy patients in north India. , 2005, Leprosy review.

[6]  H. van Mameren,et al.  The paper grip test for screening on intrinsic muscle paralysis in the foot of leprosy patients. , 2002, International journal of leprosy and other mycobacterial diseases : official organ of the International Leprosy Association.

[7]  J. Birke,et al.  Sensory testing with monofilaments in Hansen's disease and normal control subjects. , 2000, International journal of leprosy and other mycobacterial diseases : official organ of the International Leprosy Association.

[8]  A. Anderson,et al.  Reliability of Semmes Weinstein monofilament and ballpoint sensory testing, and voluntary muscle testing in Bangladesh. , 1999, Leprosy review.

[9]  A. Anderson,et al.  Intertester reliability of manual muscle strength testing in leprosy patients. , 1998, Leprosy review.

[10]  R. Oostendorp,et al.  Manual muscle strength testing: intraobserver and interobserver reliabilities for the intrinsic muscles of the hand. , 1995, Journal of hand therapy : official journal of the American Society of Hand Therapists.

[11]  J. Bell-Krotoski,et al.  The repeatability of testing with Semmes-Weinstein monofilaments. , 1987, The Journal of hand surgery.

[12]  W. Brandsma Basic nerve function assessment in leprosy patients. , 1981, Leprosy review.