Inherent Overload Protection for the Series Resonant Converter

The overload characteristics of the full bridge series resonant power converter are considered. This includes analyses of the two most common control methods presently in use. The first of these uses a current zero crossing detector to synchronize the control signals and is referred to as the ¿ controller. The second is driven by a voltage controlled oscillator and is referred to as the ¿ controller. It is shown that the ¿ controller has certain reliability advantages in that it can be designed with inherent short circuit protection. Experimental results are included for an 86 kHz converter using power metal-oxide-semiconductor field-effect transistors (MOSFETs).

[1]  F.C. Schwarz,et al.  A Method of Resonant Current Pulse Modulation for Power Converters , 1970, IEEE Transactions on Industrial Electronics and Control Instrumentation.

[2]  J. J. Biess,et al.  High voltage series resonant inverter ion engine screen supply. [SCR series resonant inverter for space applications] , 1974 .

[3]  Francisc C. Schwarz,et al.  An improved method of resonant current pulse modulation for power converters , 1976, 1975 IEEE Power Electronics Specialists Conference.

[4]  J. Ben Klaassens,et al.  A controllable secondary multikilowatt dc current source with constant maximum power factor in its three phase supply line , 1975, 1975 IEEE Power Electronics Specialists Conference.

[5]  J. Ben Klaassens,et al.  A Controllable Secondary Multikilowatt DC Current Source With Constant Maximum Power Factor in its Three-Phase Supply Line , 1976, IEEE Transactions on Industrial Electronics and Control Instrumentation.

[6]  F. Schwarz,et al.  A 95-Percent Efficient 1-kW DC Converter with an Internal Frequency of 50 kHz , 1978 .

[7]  Michael R. P. Dougherty A series resonant inverter simulation using SUPER-SCEPTRE , 1979 .

[8]  Robert C. Cole,et al.  A gated resonant inverter power processor for pulsed loads , 1981, 1981 IEEE Power Electronics Specialists Conference.

[9]  R. King,et al.  A Normalized Model for the Half-Bridge Series Resonant Converter , 1981, IEEE Transactions on Aerospace and Electronic Systems.

[10]  V. Vorperian,et al.  A complete DC analysis of the series resonant converter , 1982, 1982 IEEE Power Electronics Specialists conference.

[11]  T.A. Stuart,et al.  Modeling the Full-Bridge Series-Resonant Power Converter , 1982, IEEE Transactions on Aerospace and Electronic Systems.

[12]  R. Robson Advances in series resonant inverter technology and its effect on spacecraft employing electric propulsion , 1982 .

[13]  T. Stuart,et al.  Transformer Induced Instability of the Series Resonant Converter , 1983, IEEE Transactions on Aerospace and Electronic Systems.