Design and characterization of a miniaturized epi-illuminated microscope

The ability to observe functional and morphological changes in the brain is critical in understanding behavioral and developmental neuroscience. With advances in electronics and miniaturization, electrophysiological recordings from awake, behaving animals has allowed investigators to perform a multitude of behavioral studies by observing changes as an animal is engaged in certain tasks. Imaging offers advantages of observing structure as well as function, and the ability to monitor activity over large areas. However, imaging from an awake, behaving animal has not been explored well. We present the design and characterization of a miniaturized epi-illuminated optical system that is part of a larger goal to perform optical imaging in awake, behaving animals. The system comprises of a tunable light source and imaging optics in a small footprint of 18 mm diameter, 18 mm height and weight 5.7 grams. It offers a spatial illumination non-uniformity of 3.2% over a maximum field of view of 1.5 mm × 1.5 mm, negligible temporal illumination and temperature variation and controllable magnification. Uncorrected radial distortion was 5.3% (corrected to 1.8%) and the spatial frequency response was comparable to a reference system. The system was used to image cortical vasculature in an anesthetized rat.

[1]  B. Winegar,et al.  Isoflurane depresses hippocampal CA1 glutamate nerve terminals without inhibiting fiber volleys , 2006, BMC Neuroscience.

[2]  E. Culurciello,et al.  Voltage sensitive dye imaging system for awake and freely moving animals , 2008, 2008 IEEE Biomedical Circuits and Systems Conference.

[3]  Janne Heikkilä,et al.  A four-step camera calibration procedure with implicit image correction , 1997, Proceedings of IEEE Computer Society Conference on Computer Vision and Pattern Recognition.

[4]  Y. Sabharwal,et al.  Slit-scanning confocal microendoscope for high-resolution in vivo imaging. , 1999, Applied optics.

[5]  Zhengyou Zhang,et al.  Flexible camera calibration by viewing a plane from unknown orientations , 1999, Proceedings of the Seventh IEEE International Conference on Computer Vision.

[6]  P. Redgrave,et al.  A miniature CCD video camera for high-sensitivity light measurements in freely behaving animals , 1997, Journal of Neuroscience Methods.

[7]  C. Petersen,et al.  Visualizing the Cortical Representation of Whisker Touch: Voltage-Sensitive Dye Imaging in Freely Moving Mice , 2006, Neuron.

[8]  F. Helmchen,et al.  Ultra-compact fiber-optic two-photon microscope for functional fluorescence imaging in vivo. , 2008, Optics express.

[9]  Jean-Yves Bouguet,et al.  Camera calibration toolbox for matlab , 2001 .

[10]  T. Sejnowski,et al.  A Compact Multiphoton 3D Imaging System for Recording Fast Neuronal Activity , 2007, PloS one.

[11]  T. Tokuda,et al.  An implantable CMOS image sensor for monitoring deep brain activities of a freely moving mouse , 2008, 2008 IEEE Biomedical Circuits and Systems Conference.

[12]  I. Langmoen,et al.  The effect of isoflurane on excitatory synaptic transmission in the rat hippocampus , 1992, Acta anaesthesiologica Scandinavica.

[13]  Zoran Nenadic,et al.  Semi-chronic motorized microdrive and control algorithm for autonomously isolating and maintaining optimal extracellular action potentials. , 2005, Journal of neurophysiology.

[14]  Peter D. Burns,et al.  Slanted-Edge MTF for Digital Camera and Scanner Analysis , 2000, PICS.

[15]  E. Schutter,et al.  Miniature carrier with six independently moveable electrodes for recording of multiple single-units in the cerebellar cortex of awake rats , 1999, Journal of Neuroscience Methods.

[16]  D. Tank,et al.  Imaging Large-Scale Neural Activity with Cellular Resolution in Awake, Mobile Mice , 2007, Neuron.

[17]  Laurie D. Burns,et al.  High-speed, miniaturized fluorescence microscopy in freely moving mice , 2008, Nature Methods.