Electronic apex locator.

Locating the appropriate apical position always has been a challenge in clinical endodontics. The electronic apex locator (EAL) is used for working length determination as an important adjunct to radiography. The EAL helps to reduce the treatment time and the radiation dose, which may be higher with conventional radiographic measurements. According to recent publications, the accuracy of frequency-dependent EALs appears to be much higher compared with traditional-type EALs (simple resistance type or impedance type). This article reviews the history and the working mechanism of the currently available EALs, and suggests the correct usage of the apex locator for a better canal length measurement.

[1]  T. Baccetti,et al.  A SEM study of in vivo accuracy of the Root ZX electronic apex locator. , 1998, Journal of endodontics.

[2]  Y. Kuttler,et al.  Microscopic investigation of root apexes. , 1955, Journal of the American Dental Association.

[3]  J. C. Donnelly,et al.  In vitro evaluation of the accuracy of several electronic apex locators. , 1995, Journal of endodontics.

[4]  H. Ounsi,et al.  In vitro evaluation of the reliability of the Endex electronic apex locator. , 1998, Journal of endodontics.

[5]  N Inoue,et al.  A simple and accurate way to measuring root canal length. , 1985, Journal of endodontics.

[6]  M Ohashi,et al.  A new method and apparatus for measuring root canal length. , 1986, The Journal of Nihon University School of Dentistry.

[7]  K Gulabivala,et al.  An in vivo evaluation of the ENDEX and RCM Mark II electronic apex locators in root canals with different contents. , 1995, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[8]  K I Knowles,et al.  Effect of preflaring on Root ZX apex locators. , 1999, Journal of endodontics.

[9]  M. A. Martínez-Lozano,et al.  Methodological considerations in the determination of working length. , 2001, International endodontic journal.

[10]  J. Marshall,et al.  An in vivo comparison of two frequency-based electronic apex locators. , 2003, Journal of endodontics.

[11]  C Kobayashi,et al.  A new engine-driven canal preparation system with electronic canal measuring capability. , 1997, Journal of endodontics.

[12]  J. Ushiyama,et al.  New principle and method for measuring the root canal length. , 1983, Journal of endodontics.

[13]  S. Friedman,et al.  Electronic length measurement using small and large files in enlarged canals. , 1996, International endodontic journal.

[14]  E A BeGole,et al.  An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals. , 1998, Journal of endodontics.

[15]  A L Frank,et al.  An in vivo evaluation of Endex electronic apex locator. , 1993, Journal of endodontics.

[16]  A Katz,et al.  Electronic apex locator: a useful tool for root canal treatment in the primary dentition. , 1996, ASDC journal of dentistry for children.

[17]  T. Macfarlane,et al.  The effect of an apex locator on exposure to radiation during endodontic therapy. , 2002, Journal of endodontics.

[18]  R Weiger,et al.  Frequency of overinstrumentation with an acceptable radiographic working length. , 2001, Journal of endodontics.

[19]  D. H. Pratten,et al.  Comparison of radiographic and electronic working lengths. , 1996, Journal of endodontics.

[20]  D. Pitts,et al.  Determination of impedance changes at varying frequencies in relation to root canal file position and irrigant. , 1997, Journal of endodontics.

[21]  C Kobayashi,et al.  Electronic canal length measurement. , 1995, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[22]  S Shabahang,et al.  An in vivo evaluation of Root ZX electronic apex locator. , 1996, Journal of endodontics.

[23]  Roland Weiger,et al.  The ability of root ZX apex locator to reduce the frequency of overestimated radiographic working length. , 2002, Journal of endodontics.

[24]  E J Hovland,et al.  An evaluation of the Apex Locator Endocater. , 1990, Journal of endodontics.

[25]  R. Olson,et al.  Clinical evaluation of five electronic root canal length measuring instruments. , 1990, Journal of endodontics.

[26]  J. Simon,et al.  In vivo measurement accuracy in vital and necrotic canals with the Endex apex locator. , 1993, Journal of endodontics.

[27]  Young-Joo Kim,et al.  Clinical accuracy of a new apex locator with an automatic compensation circuit. , 2002, Journal of endodontics.

[28]  McDonald Nj,et al.  The electronic determination of working length. , 1992 .

[29]  W A Walker,et al.  An in vitro evaluation of the accuracy of the root ZX in the presence of various irrigants. , 2001, Journal of endodontics.

[30]  M H Nekoofar,et al.  The accuracy of the Neosono Ultima EZ apex locator using files of different alloys: an in vitro study. , 2002, Journal of the California Dental Association.

[31]  I J Soares,et al.  In vitro evaluation of an audiometric device in locating the apical foramen of teeth. , 1994, Endodontics & dental traumatology.

[32]  A. Kaufman,et al.  Accuracy of a new apex locator: an in vitro study. , 2002, International endodontic journal.

[33]  Z. Fuss,et al.  Determination of location of root perforations by electronic apex locators. , 1996, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[34]  I. Sunada New Method for Measuring the Length of the Root Canal , 1962 .

[35]  Dejan Krizaj,et al.  Numerical computation of impedances of a human tooth for estimation of the root canal length , 2002, IEEE Transactions on Biomedical Engineering.

[36]  L Vajrabhaya,et al.  Accuracy of apex locator. , 1997, Endodontics & dental traumatology.

[37]  H Suda,et al.  New electronic canal measuring device based on the ratio method. , 1994, Journal of endodontics.

[38]  E. Rivera,et al.  Accuracy of the Endex with variations in canal irrigants and foramen size. , 1993, Journal of endodontics.

[39]  H. Steiman,et al.  The influence of sodium hypochlorite irrigation on the accuracy of the Root ZX electronic apex locator. , 2002, Journal of endodontics.

[40]  A. Kielbassa,et al.  Clinical evaluation of the measuring accuracy of ROOT ZX in primary teeth. , 2003, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[41]  P M Dummer,et al.  The position and topography of the apical canal constriction and apical foramen. , 1984, International endodontic journal.

[42]  N P Chandler,et al.  Electronic apex locators. , 2004, International endodontic journal.

[43]  L. Huang,et al.  Variables affecting electronic root canal measurement. , 1992, International endodontic journal.

[44]  N Inoue,et al.  An audiometric method for determining the length of root canals. , 1973, Journal of the Canadian Dental Association.

[45]  G. Bergenholtz,et al.  Periodontal wound healing following intentional root perforations in permanent teeth of Macaca mulatta. , 1986, International endodontic journal.

[46]  L. E. Custer Exact Method of Locating the Apical Foramen , 1918, The Dental register.

[47]  A Naaman,et al.  In vitro evaluation of the reliability of the Root ZX electronic apex locator. , 1999, International endodontic journal.

[48]  C. Ferrer‐Luque,et al.  In vitro evaluation of the accuracy of three electronic apex locators. , 2004, Journal of Endodontics.

[49]  D. Ricucci Apical limit of root canal instrumentation and obturation, part 1. Literature review. , 2002, International endodontic journal.

[50]  L Tronstad,et al.  Accuracy of an electronic apex locator under controlled clinical conditions. , 1985, Endodontics & dental traumatology.

[51]  F Lutz,et al.  An in vivo comparison of gradient and absolute impedance electronic apex locators. , 1996, Journal of endodontics.

[52]  Oliver Stamm,et al.  Influence of the canal contents on the electrical assisted determination of the length of root canals. , 2002, Journal of endodontics.

[53]  L. Huang,et al.  An experimental study of the principle of electronic root canal measurement. , 1987, Journal of endodontics.

[54]  Z. Fuss,et al.  Reliability of different electronic apex locators to detect root perforations in vitro. , 1997, International endodontic journal.

[55]  S. J. Lee,et al.  Root canal length measurement in teeth with electrolyte compensation , 2002, Medical and Biological Engineering and Computing.

[56]  J G Burch,et al.  The relationship of the apical foramen to the anatomic apex of the tooth root. , 1972, Oral surgery, oral medicine, and oral pathology.

[57]  Fernando Goldberg,et al.  In vitro measurement accuracy of an electronic apex locator in teeth with simulated apical root resorption. , 2002, Journal of endodontics.