Management of pellucid marginal degeneration with intracorneal ring segments.

PURPOSE To present intracorneal ring segments for potential management of pellucid marginal degeneration. METHODS A 41-year-old man with pellucid marginal degeneration with poor visual acuity due to irregular astigmatism was treated with Intacs microthin insert (KeraVision, Fremont, Calif) in the left eye. RESULTS Uncorrected visual acuity improved from 2/60 to 6/60 following the procedure. The procedure completely eliminated myopia of -8.00 diopters and improved the irregularity of the astigmatism, although it did not change its magnitude. CONCLUSIONS Insertion of the intracorneal ring segment improves visual acuity in pellucid marginal degeneration by flattening the central corneal protrusion, thus reducing myopia and improving the astigmatism irregularity.