Impact of sensor measurement error on sensor positioning in water quality monitoring networks

This paper studies the impact of sensor measurement error on designing a water quality monitoring network for a river system, and shows that robust sensor locations can be obtained when an optimization algorithm is combined with a statistical process control (SPC) method. Specifically, we develop a possible probabilistic model of sensor measurement error and the measurement error model is embedded into a simulation model of a river system. An optimization algorithm is used to find the optimal sensor locations that minimize the expected time until a spill detection in the presence of a constraint on the probability of detecting a spill. The experimental results show that the optimal sensor locations are highly sensitive to the variability of measurement error and false alarm rates are often unacceptably high. An SPC method is useful in finding thresholds that guarantee a false alarm rate no more than a pre-specified target level, and an optimization algorithm combined with the thresholds finds a robust sensor network.

[1]  Seong-Hee Kim,et al.  Penalty Function with Memory for Discrete Optimization via Simulation with Stochastic Constraints , 2015, Oper. Res..

[2]  Fred Spiring,et al.  Introduction to Statistical Quality Control , 2007, Technometrics.

[3]  Ilker T. Telci,et al.  Optimal water quality monitoring network design for river systems. , 2009, Journal of environmental management.

[4]  Barry L. Nelson,et al.  Optimization via simulation over discrete decision variables , 2010 .

[5]  Marc F. P. Bierkens,et al.  Designing a monitoring network for detecting groundwater pollution with stochastic simulation and a cost model , 2006 .

[6]  Leyuan Shi,et al.  Nested Partitions Method for Stochastic Optimization , 2000 .

[7]  Seong-Hee Kim,et al.  Designing an optimal water quality monitoring network for river systems using constrained discrete optimization via simulation , 2014 .

[8]  Gerald R. North,et al.  Formalism for Comparing Rain Estimation Designs , 1989 .

[9]  James R. Wilson,et al.  A distribution-free tabular CUSUM chart for autocorrelated data , 2007 .

[10]  M. Storey,et al.  Advances in on-line drinking water quality monitoring and early warning systems. , 2011, Water research.

[11]  Hui Wang,et al.  Bayesian approach to contaminant source characterization in water distribution systems: adaptive sampling framework , 2013, Stochastic Environmental Research and Risk Assessment.

[12]  Chulsang Yoo,et al.  On the sampling errors from raingauges and microwave attenuation measurements , 2000 .

[13]  Mustafa M. Aral,et al.  Real Time Optimal Monitoring Network Design in River Networks , 2008 .

[14]  Robert O Strobl,et al.  Network design for water quality monitoring of surface freshwaters: a review. , 2008, Journal of environmental management.

[15]  Mustafa M. Aral,et al.  Contaminant Source Location Identification in River Networks Using Water Quality Monitoring Systems for Exposure Analysis , 2011 .