Quantitative electrochemical metalloimmunoassay for TFF3 in urine using a paper analytical device.

We report a paper-based assay platform for the detection of the kidney disease marker Trefoil Factor 3 (TFF3) in human urine. The sensor is based on a quantitative metalloimmunoassay that can determine TFF3 concentrations via electrochemical detection of environmentally stable silver nanoparticle (AgNP) labels attached to magnetic microbeads via a TFF3 immunosandwich. The paper electroanalytical device incorporates two preconcentration steps that make it possible to detect concentrations of TFF3 in human urine at the low end of the target TFF3 concentration range (0.03-7.0 μg mL(-1)). Importantly, the paper device provides a level of accuracy for TFF3 determination in human urine equivalent to that of a commercial kit. The paper sensor has a dynamic range of ∼2.5 orders of magnitude, only requires a simple, one-step incubation protocol, and is fast, requiring only 10 min to complete. The cost of the materials at the prototypic laboratory scale, excluding reagents, is just US$0.42.

[1]  Ali Khademhosseini,et al.  Microfluidics for drug discovery and development: from target selection to product lifecycle management. , 2008, Drug discovery today.

[2]  Shenguang Ge,et al.  Photoelectrochemical lab-on-paper device equipped with a porous Au-paper electrode and fluidic delay-switch for sensitive detection of DNA hybridization. , 2013, Lab on a chip.

[3]  Despina P Kalogianni,et al.  Carbon nano-strings as reporters in lateral flow devices for DNA sensing by hybridization , 2011, Analytical and bioanalytical chemistry.

[4]  Orawon Chailapakul,et al.  Electrochemical detection for paper-based microfluidics. , 2009, Analytical chemistry.

[5]  Peter Kauffman,et al.  Microfluidics without pumps: reinventing the T-sensor and H-filter in paper networks. , 2010, Lab on a chip.

[6]  J. Wölcke,et al.  Miniaturized HTS technologies - uHTS. , 2001, Drug discovery today.

[7]  R. Schasfoort,et al.  TUTORIAL REVIEW , 2001 .

[8]  T. Reiter,et al.  Trefoil Factor 1 Excretion Is Increased in Early Stages of Chronic Kidney Disease , 2015, PloS one.

[9]  R. Crooks,et al.  Three-dimensional paper microfluidic devices assembled using the principles of origami. , 2011, Journal of the American Chemical Society.

[10]  Mark Pinches,et al.  Characterization of renal biomarkers for use in clinical trials: biomarker evaluation in healthy volunteers , 2014, Drug design, development and therapy.

[11]  P. Hewitt,et al.  Biomarkers for Drug-Induced Renal Damage and Nephrotoxicity—An Overview for Applied Toxicology , 2011, The AAPS Journal.

[12]  Claudio Parolo,et al.  Paper-based nanobiosensors for diagnostics. , 2013, Chemical Society reviews.

[13]  T. Lindmo,et al.  Analyte and label binding assay read by flow cytometry. , 1996, Clinical chemistry.

[14]  E. Nexo,et al.  Trefoil factor family peptides in human saliva and cyclical cervical mucus. Method evaluation and results on healthy individuals , 2011, Clinical chemistry and laboratory medicine.

[15]  Shenguang Ge,et al.  Supplementary Material (esi) for Chemical Communications Electronic Supplementary Information a Disposable Paper-based Electrochemical Sensor with Addressable Electrode Array for Cancer Screening , 2022 .

[16]  Richard M Crooks,et al.  Paper electrochemical device for detection of DNA and thrombin by target-induced conformational switching. , 2014, Analytical chemistry.

[17]  P. Connolly Clinical diagnostics opportunities for biosensors and bioelectronics. , 1995, Biosensors & bioelectronics.

[18]  S. T. Lee,et al.  Small-Diameter Silicon Nanowire Surfaces , 2003, Science.

[19]  Richard M Crooks,et al.  Paper-based SlipPAD for high-throughput chemical sensing. , 2013, Analytical chemistry.

[20]  S. Calza,et al.  Trefoil factor 3: a novel serum marker identified by gene expression profiling in high-grade endometrial carcinomas , 2008, British Journal of Cancer.

[21]  G. Whitesides,et al.  Paper-based piezoresistive MEMS sensors. , 2011, Lab on a chip.

[22]  Paul Yager,et al.  Highly Sensitive Immunoassay Based on Controlled Rehydration of Patterned Reagents in a 2-Dimensional Paper Network , 2014, Analytical chemistry.

[23]  Xi Chen,et al.  DNA circuits as amplifiers for the detection of nucleic acids on a paperfluidic platform. , 2012, Lab on a chip.

[24]  Richard M Crooks,et al.  Three-dimensional wax patterning of paper fluidic devices. , 2014, Langmuir : the ACS journal of surfaces and colloids.

[25]  William F Weiss,et al.  High-throughput analysis of concentration-dependent antibody self-association. , 2011, Biophysical journal.

[26]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[27]  S. T. Phillips,et al.  Fluidic timers for time-dependent, point-of-care assays on paper. , 2010, Analytical chemistry.

[28]  Ali Kemal Yetisen,et al.  Paper-based microfluidic point-of-care diagnostic devices. , 2013, Lab on a chip.

[29]  Ting Du,et al.  Circulating Serum Trefoil Factor 3 (TFF3) Is Dramatically Increased in Chronic Kidney Disease , 2013, PloS one.

[30]  Yen-Yuan Chen,et al.  Long-term risk of coronary events after AKI. , 2014, Journal of the American Society of Nephrology : JASN.

[31]  Richard M Crooks,et al.  Hollow-channel paper analytical devices. , 2013, Analytical chemistry.

[32]  Joseph V Bonventre,et al.  Acute kidney injury, mortality, length of stay, and costs in hospitalized patients. , 2005, Journal of the American Society of Nephrology : JASN.

[33]  Andrew Ustianowski,et al.  Tropical infectious diseases: Diagnostics for the developing world , 2004, Nature Reviews Microbiology.

[34]  Emanuel Carrilho,et al.  Paper-based ELISA. , 2010, Angewandte Chemie.

[35]  C. K. Koo,et al.  An inkjet-printed electrowetting valve for paper-fluidic sensors. , 2013, The Analyst.

[36]  Richard M Crooks,et al.  Simple, sensitive, and quantitative electrochemical detection method for paper analytical devices. , 2014, Analytical chemistry.

[37]  Shenguang Ge,et al.  Electrochemical DNA sensor based on three-dimensional folding paper device for specific and sensitive point-of-care testing , 2012 .

[38]  J. Justin Gooding,et al.  Recent Advances in Paper-Based Sensors , 2012, Sensors.

[39]  G. S. Wilson,et al.  Studies of the 'hook' effect in the one-step sandwich immunoassay. , 1992, Journal of immunological methods.

[40]  Amy G. Aslamkhan,et al.  Urinary biomarkers trefoil factor 3 and albumin enable early detection of kidney tubular injury , 2010, Nature Biotechnology.

[41]  E. Nexo,et al.  Validation of commercial assays for measurements of trefoil factor family peptides in serum , 2011, Clinical chemistry and laboratory medicine.

[42]  Yeoheung Yun,et al.  High performance magnesium anode in paper-based microfluidic battery, powering on-chip fluorescence assay. , 2014, Biomicrofluidics.

[43]  R. Richards-Kortum,et al.  A paper and plastic device for performing recombinase polymerase amplification of HIV DNA. , 2012, Lab on a chip.

[44]  Bingling Li,et al.  DNA detection using origami paper analytical devices. , 2013, Analytical chemistry.

[45]  Orawon Chailapakul,et al.  Development of automated paper-based devices for sequential multistep sandwich enzyme-linked immunosorbent assays using inkjet printing. , 2013, Lab on a chip.

[46]  Glenda C Gobe,et al.  Biomarkers in chronic kidney disease: a review. , 2011, Kidney international.

[47]  Joseph V Bonventre,et al.  Next-generation biomarkers for detecting kidney toxicity , 2010, Nature Biotechnology.

[48]  Yi Lu,et al.  Aptamer-based origami paper analytical device for electrochemical detection of adenosine. , 2012, Angewandte Chemie.

[49]  Jaclyn A. Adkins,et al.  Recent developments in paper-based microfluidic devices. , 2015, Analytical chemistry.

[50]  G. Eknoyan,et al.  Prevalence of chronic kidney disease and decreased kidney function in the adult US population: Third National Health and Nutrition Examination Survey. , 2003, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[51]  S A. Sundberg,et al.  Microchip-based systems for target validation and HTS. , 2000, Drug discovery today.

[52]  Chao-Min Cheng,et al.  Paper - a potential platform in pharmaceutical development. , 2015, Trends in biotechnology.

[53]  S. Shevkoplyas,et al.  Integrated separation of blood plasma from whole blood for microfluidic paper-based analytical devices. , 2012, Lab on a chip.

[54]  Shenguang Ge,et al.  Photoelectrochemical lab-on-paper device based on an integrated paper supercapacitor and internal light source. , 2013, Analytical chemistry.

[55]  G. Whitesides,et al.  Patterned paper as a platform for inexpensive, low-volume, portable bioassays. , 2007, Angewandte Chemie.

[56]  W. Marsden I and J , 2012 .

[57]  A. Köttgen,et al.  Trefoil Factor 3 Predicts Incident Chronic Kidney Disease: A Case-Control Study Nested within the Atherosclerosis Risk in Communities (ARIC) Study , 2011, American Journal of Nephrology.

[58]  Peng Xue,et al.  Paper-based microfluidic electrochemical immunodevice integrated with nanobioprobes onto graphene film for ultrasensitive multiplexed detection of cancer biomarkers. , 2013, Analytical chemistry.

[59]  Joakim Lundeberg,et al.  Activated paper surfaces for the rapid hybridization of DNA through capillary transport. , 2012, Analytical chemistry.

[60]  George M Whitesides Viewpoint on "Dissolvable fluidic time delays for programming multi-step assays in instrument-free paper diagnostics". , 2013, Lab on a chip.

[61]  W. Hoffmann Trefoil factors , 2005, Cellular and Molecular Life Sciences CMLS.

[62]  Long Luo,et al.  Paper-Based Sensor for Electrochemical Detection of Silver Nanoparticle Labels by Galvanic Exchange , 2016 .

[63]  S. Poulsen,et al.  Development and evaluation of an ELISA for human trefoil factor 3. , 2002, Clinical chemistry.

[64]  Huan‐Tsung Chang,et al.  Detection of mercury(II) ions using colorimetric gold nanoparticles on paper-based analytical devices. , 2014, Analytical chemistry.

[65]  P. Lisowski,et al.  Microfluidic Paper-Based Analytical Devices (μPADs) and Micro Total Analysis Systems (μTAS): Development, Applications and Future Trends , 2013, Chromatographia.