Measuring Arterial Diameters for Surgery Assistance, Patient Customized Endovascular Prosthesis Design and Post-Surgery Evaluation

This paper presents a method for arterial diameter measurement for the patient customization of endovascular prosthesis and for the assistance in preoperative procedures. The use of three-dimensional reconstruction and organ representation through a traversable geometric representation, known as doubly linked face list (DLFL), which guarantees some topological properties, allows the measurement of the diameter of the polygons formed by the intersection between any arbitrary plane and the organ to be performed in a very efficient way

[1]  R. S. Mitchell,et al.  Aortic neck morphology after endovascular repair of descending thoracic aortic aneurysms. , 2006, Journal of vascular surgery.

[2]  H H Eckstein,et al.  Morphometry and Classification in Abdominal Aortic Aneurysms: Patient Selection for Endovascular and Open Surgery , 1997, Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery.

[3]  G. Rubin,et al.  Impact of aortoiliac tortuosity on endovascular repair of abdominal aortic aneurysms: evaluation of 3D computer-based assessment. , 2001, Journal of vascular surgery.

[4]  Thomas Boehm,et al.  Computerized Modeling Based on Spiral CT Data for Noninvasive Determination of Aortic Stent-Graft Length , 2002, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[5]  Daniel Duarte Abdala,et al.  Three-dimensional visualization of radiological images using octrees , 2004 .

[6]  Rüdiger Dillmann,et al.  Split-and-Merge Segmentation using Octrees , 1995 .

[7]  Rodney A. White,et al.  Abdominal Aortic Aneurysm Rupture following Endoluminal Graft Deployment: Report of a Predictable Event , 2000, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[8]  Herculano Haymussi de Biasi Desenvolvimento de uma metodologia de visão computacional para o auxílio no planejamento cirúrgico no implante de próteses endoluminais , 2002 .

[9]  VINOD SRINIVASAN,et al.  Topological Construction of 2-Manifold Meshes from Arbitrary Polygonal Data , 2002 .

[10]  Theodosios Pavlidis,et al.  Picture Segmentation by a Tree Traversal Algorithm , 1976, JACM.

[11]  Roberto Chiesa,et al.  Midterm clinical success and behavior of the aneurysm sac after endovascular AAA repair with the Excluder graft. , 2005, Journal of vascular surgery.

[12]  G. Nano,et al.  Mid-term results after endovascular repair of abdominal aortic aneurysms: a four-year experience. , 2004, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[13]  Ergun Akleman,et al.  Guaranteeing the 2-Manifold Property for Meshes with doubly Linked Face List , 1999, Int. J. Shape Model..

[14]  William E. Lorensen,et al.  Marching cubes: A high resolution 3D surface construction algorithm , 1987, SIGGRAPH.

[15]  Martti Mäntylä,et al.  Introduction to Solid Modeling , 1988 .

[16]  Ergun Akleman,et al.  Guaranteeing 2-manifold property for meshes , 1999, Proceedings Shape Modeling International '99. International Conference on Shape Modeling and Applications.

[17]  M. Carter Computer graphics: Principles and practice , 1997 .