2D wavelet-analysis-based calibration technique for flat-panel imaging detectors: application in cone beam volume CT

The application of the newly developed flat panel x-ray imaging detector in cone beam volume CT has attracted increasing interest recently. Due to an imperfect solid state array manufacturing process, however, defective elements, gain non-uniformity and offset image unavoidably exist in all kinds of flat panel x-ray imaging detectors, which will cause severe streak and ring artifacts in a cone beam reconstruction image and severely degrade image quality. A calibration technique, in which the artifacts resulting from the defective elements, gain non-uniformity and offset image can be reduced significantly, is presented in this paper. The detection of defective elements is distinctively based upon two-dimensional (2D) wavelet analysis. Because of its inherent localizability in recognizing singularities or discontinuities, wavelet analysis possesses the capability of detecting defective elements over a rather large x-ray exposure range, e.g., 20% to approximately 60% of the dynamic range of the detector used. Three-dimensional (3D) images of a low-contrast CT phantom have been reconstructed from projection images acquired by a flat panel x-ray imaging detector with and without calibration process applied. The artifacts caused individually by defective elements, gain non-uniformity and offset image have been separated and investigated in detail, and the correlation with each other have also been exposed explicitly. The investigation is enforced by quantitative analysis of the signal to noise ratio (SNR) and the image uniformity of the cone beam reconstruction image. It has been demonstrated that the ring and streak artifacts resulting from the imperfect performance of a flat panel x-ray imaging detector can be reduced dramatically, and then the image qualities of a cone beam reconstruction image, such as contrast resolution and image uniformity are improved significantly. Furthermore, with little modification, the calibration technique presented here is also applicable to the flat panel x-ray imaging detector in digital radiography (DR), fluoroscopy (DF) and mammography.

[1]  Norbert Conrads,et al.  Dynamic x-ray imaging system based on an amorphous silicon thin-film array , 1998, Medical Imaging.

[2]  Ruola Ning,et al.  Image-intensifier-based volume tomographic angiography imaging system , 1997, Medical Imaging.

[3]  Manabu Tanaka,et al.  Development of a selenium-based flat-panel detector for real-time radiography and fluoroscopy , 1998, Medical Imaging.

[4]  Wei Zhao,et al.  Flat panel detector for digital radiology using active matrix readout of amorphous selenium , 1997, Medical Imaging.

[5]  Stéphane Mallat,et al.  Singularity detection and processing with wavelets , 1992, IEEE Trans. Inf. Theory.

[6]  Brian G. Rodricks,et al.  Radiographic imaging characteristics of a direct conversion detector using selenium and thin film transistor array , 1997, Medical Imaging.

[7]  Ruola Ning,et al.  Selenium flat-panel detector-based volume tomographic angiography imaging: phantom studies , 1998, Medical Imaging.

[8]  John A. Rowlands,et al.  Detective quantum efficiency of direct flat-panel x-ray imaging detectors for fluoroscopy , 1998, Medical Imaging.

[9]  Maxwell J. Allen,et al.  Characterization of an amorphous-silicon fluoroscopic imager , 1997, Medical Imaging.

[10]  Norbert Jung,et al.  Technical and clinical results of an experimental flat dynamic (digital) x-ray image detector (FDXD) system with real-time corrections , 1998, Medical Imaging.

[11]  Isaias D. Job,et al.  Flat-panel imaging system for fluoroscopy applications , 1998, Medical Imaging.

[12]  Richard L. Weisfield,et al.  Improved page-size 127-um-pixel amorphous-silicon image sensor for x-ray diagnostic medical imaging applications , 1997, Medical Imaging.

[13]  John M. Boone,et al.  Flat-field correction technique for digital detectors , 1998, Medical Imaging.

[14]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .