Validation of a 3D computational fluid-structure interaction model simulating flow through an elastic aperture.

This work presents a validation of a fluid-structure interaction computational model simulating the flow conditions in an in vitro mock heart chamber modeling mitral valve regurgitation during the ejection phase during which the trans-valvular pressure drop and valve displacement are not as large. The mock heart chamber was developed to study the use of 2D and 3D color Doppler techniques in imaging the clinically relevant complex intra-cardiac flow events associated with mitral regurgitation. Computational models are expected to play an important role in supporting, refining, and reinforcing the emerging 3D echocardiographic applications. We have developed a 3D computational fluid-structure interaction algorithm based on a semi-implicit, monolithic method, combined with an arbitrary Lagrangian-Eulerian approach to capture the fluid domain motion. The mock regurgitant mitral valve corresponding to an elastic plate with a geometric orifice, was modeled using 3D elasticity, while the blood flow was modeled using the 3D Navier-Stokes equations for an incompressible, viscous fluid. The two are coupled via the kinematic and dynamic conditions describing the two-way coupling. The pressure, the flow rate, and orifice plate displacement were measured and compared with numerical simulation results. In-line flow meter was used to measure the flow, pressure transducers were used to measure the pressure, and a Doppler method developed by one of the authors was used to measure the axial displacement of the orifice plate. The maximum recorded difference between experiment and numerical simulation for the flow rate was 4%, the pressure 3.6%, and for the orifice displacement 15%, showing excellent agreement between the two.

[1]  J Vierendeels,et al.  Validation of a Fluid–Structure Interaction Model of a Heart Valve using the Dynamic Mesh Method in Fluent , 2004, Computer methods in biomechanics and biomedical engineering.

[2]  M Cerrolaza,et al.  Analysis of 3D transient blood flow passing through an artificial aortic valve by Lattice-Boltzmann methods. , 1998, Journal of biomechanics.

[3]  A two-dimensional fluid-structure interaction model of the aortic valve [correction of value]. , 2000, Journal of biomechanics.

[4]  T. Tezduyar,et al.  Space-time finite element computation of compressible flows involving moving boundaries and interfaces☆ , 1993 .

[5]  C. W. Hirt,et al.  An Arbitrary Lagrangian-Eulerian Computing Method for All Flow Speeds , 1997 .

[6]  Annalisa Quaini,et al.  Algorithms for fluid-structure interaction problems arising in hemodynamics , 2009 .

[7]  W. Zoghbi,et al.  In vitro validation of real-time three-dimensional color Doppler echocardiography for direct measurement of proximal isovelocity surface area in mitral regurgitation. , 2007, The American journal of cardiology.

[8]  S. Osher,et al.  A Level Set Formulation of Eulerian Interface Capturing Methods for Incompressible Fluid Flows , 1996 .

[9]  Annalisa Quaini,et al.  Splitting Methods Based on Algebraic Factorization for Fluid-Structure Interaction , 2008, SIAM J. Sci. Comput..

[10]  R. Codina Stabilized finite element approximation of transient incompressible flows using orthogonal subscales , 2002 .

[11]  Annalisa Quaini,et al.  A Three-Dimensional Computational Fluid Dynamics Model of Regurgitant Mitral Valve Flow: Validation Against In Vitro Standards and 3D Color Doppler Methods , 2011, Cardiovascular engineering and technology.

[12]  C. Hartley,et al.  An ultrasonic method for measuring tissue displacement: technical details and validation for measuring myocardial thickening , 1991, IEEE Transactions on Biomedical Engineering.

[13]  P J Dionne,et al.  Three‐Dimensional Coupled Fluid‐Structure Simulation of Pericardial Bioprosthetic Aortic Valve Function , 1997, ASAIO journal.

[14]  W. Zoghbi,et al.  Three-dimensional ultrasound imaging model of mitral valve regurgitation: design and evaluation. , 2008, Ultrasound in medicine & biology.

[15]  P. J. O'Rourke,et al.  Three-Dimensional Computational Fluid Dynamics , 1998 .

[16]  Alberto Redaelli,et al.  3-D simulation of the SJM bileaflet valve opening process: fluid-structure interaction study and experimental validation , 2004 .

[17]  R. Glowinski,et al.  A fictitious domain method for external incompressible viscous flow modeled by Navier-Stokes equations , 1994 .

[18]  C. Peskin The immersed boundary method , 2002, Acta Numerica.

[19]  Giovanna Guidoboni,et al.  Blood Flow in Compliant Arteries: An Effective Viscoelastic Reduced Model, Numerics, and Experimental Validation , 2006, Annals of Biomedical Engineering.

[20]  R. Cheng,et al.  Three-Dimensional Fluid-Structure Interaction Simulation of Bileaflet Mechanical Heart Valve Flow Dynamics , 2004, Annals of Biomedical Engineering.

[21]  A Karac,et al.  Validation of a fluid-structure interaction numerical model for predicting flow transients in arteries. , 2009, Journal of biomechanics.

[22]  Charles A. Taylor,et al.  A coupled momentum method for modeling blood flow in three-dimensional deformable arteries , 2006 .

[23]  M. Olufsen,et al.  Numerical Simulation and Experimental Validation of Blood Flow in Arteries with Structured-Tree Outflow Conditions , 2000, Annals of Biomedical Engineering.

[24]  A. Quarteroni,et al.  A SEMI-IMPLICIT APPROACH FOR FLUID-STRUCTURE INTERACTION BASED ON AN ALGEBRAIC FRACTIONAL STEP METHOD , 2007 .

[25]  S. Mittal,et al.  A new strategy for finite element computations involving moving boundaries and interfaces—the deforming-spatial-domain/space-time procedure. II: Computation of free-surface flows, two-liquid flows, and flows with drifting cylinders , 1992 .

[26]  Fabio Nobile,et al.  Added-mass effect in the design of partitioned algorithms for fluid-structure problems , 2005 .

[27]  Annalisa Quaini,et al.  Modular vs. non-modular preconditioners for fluid-structure systems with large added-mass effect , 2008 .

[28]  Yousef Saad,et al.  Iterative methods for sparse linear systems , 2003 .

[29]  van de Fn Frans Vosse,et al.  Evaluation of a fictitious domain method for predicting dynamic response of mechanical heart valves , 2004 .

[30]  Alberto Redaelli,et al.  3-D simulation of the St. Jude Medical bileaflet valve opening process: fluid-structure interaction study and experimental validation. , 2004, The Journal of heart valve disease.

[31]  Rui Cheng,et al.  Two-dimensional fluid-structure interaction simulation of bileaflet mechanical heart valve flow dynamics. , 2003, The Journal of heart valve disease.

[32]  Fabio Nobile,et al.  Numerical approximation of fluid-structure interaction problems with application to haemodynamics , 2001 .

[33]  Jens-Dominik Mueller,et al.  Validation of a fluid–structure interaction model for a bileaflet mechanical heart valve , 2008 .

[34]  M. Enriquez-Sarano,et al.  Chapter 76 – Mitral Regurgitation , 2009 .

[35]  Wing Kam Liu,et al.  Lagrangian-Eulerian finite element formulation for incompressible viscous flows☆ , 1981 .

[36]  S. Čanić,et al.  A two-dimensional effective model describing fluid–structure interaction in blood flow: analysis, simulation and experimental validation , 2005 .

[37]  P. Tallec,et al.  Load and motion transfer algorithms for fluid/structure interaction problems with non-matching discrete interfaces: Momentum and energy conservation, optimal discretization and application to aeroelasticity , 1998 .

[38]  T. Tezduyar,et al.  A new strategy for finite element computations involving moving boundaries and interfaces—the deforming-spatial-domain/space-time procedure. I: The concept and the preliminary numerical tests , 1992 .