3-D airborne ultrasound synthetic aperture imaging based on capacitive micromachined ultrasonic transducers.

In this paper, we present an airborne 3-D volumetric imaging system based on capacitive micromachined ultrasonic transducers (CMUTs). For this purpose we fabricated 89-kHz CMUTs where each CMUT is made of a circular single-crystal silicon plate with a radius of 1mm and a thickness of 20 μm, which is actuated by electrostatic force through a 20-μm vacuum gap. The measured transmit sensitivity at 300-V DC bias is 14.6 Pa/V and 24.2 Pa/V, when excited by a 30-cycle burst and a continuous wave, respectively. The measured receive sensitivity at 300-V DC bias is 16.6 mV/Pa (-35.6 dB re 1 V/Pa) for a 30-cycle burst. A 26×26 2-D array was implemented by mechanical scanning a co-located transmitter and receiver using the classic synthetic aperture (CSA) method. The measurement of a 1.6λ-size target at a distance of 500 mm presented a lateral resolution of 3.17° and also showed good agreement with the theoretical point spread function. The 3-D imaging of two plates at a distance of 350 mm and 400 mm was constructed to exhibit the capability of the imaging system. This study experimentally demonstrates that a 2-D CMUT array can be used for practical 3-D imaging applications in air, such as a human-machine interface.

[1]  K. Park,et al.  Dynamic response of an array of flexural plates in acoustic medium. , 2012, The Journal of the Acoustical Society of America.

[2]  Adrian Neild,et al.  Radiated fields of capacitive micromachined ultrasonic transducers in air. , 2003, The Journal of the Acoustical Society of America.

[3]  A. J. Zuckerwar,et al.  Atmospheric absorption of sound: Further developments , 1995 .

[4]  O. Oralkan,et al.  Volumetric ultrasound imaging using 2-D CMUT arrays , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  D. Schindel,et al.  The design and characterization of micromachined air-coupled capacitance transducers , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  L. Capineri,et al.  Piezo-polymer transducers for ultrasonic imaging in air , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  Butrus T. Khuri-Yakub,et al.  Minimally Redundant 2-D Array Designs for 3-D Medical Ultrasound Imaging , 2009, IEEE Transactions on Medical Imaging.

[8]  Ultrasonic Position Measurement using Phased Array Microsensors with Resonant Frequency Variation , 2007, TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference.

[9]  Abdullah Atalar,et al.  Micromachined two-dimensional array piezoelectrically actuated transducers , 1998 .

[10]  C. Wykes,et al.  Diagnostic measurements in capacitive transducers , 1993 .

[11]  Hideo Furuhashi,et al.  Three-dimensional imaging sensor system using an ultrasonic array sensor and a camera , 2010, 2010 IEEE Sensors.

[12]  T. Kanashima,et al.  Influences of perforation ratio in characteristics of capacitive micromachined ultrasonic transducers in air , 2011 .

[13]  Abdelhak M. Zoubir,et al.  Three-Dimensional Ultrasound Imaging in Air using a 2D Array on a Fixed Platform , 2007, 2007 IEEE International Conference on Acoustics, Speech and Signal Processing - ICASSP '07.

[14]  C Wykes,et al.  The performance of capacitive ultrasonic transducers using v-grooved backplates , 1991 .

[15]  S. Harput,et al.  Ultrasonic Phased Array Device for Acoustic Imaging in Air , 2008, IEEE Sensors Journal.

[16]  Richard J. Przybyla,et al.  In-Air Rangefinding With an AlN Piezoelectric Micromachined Ultrasound Transducer , 2011, IEEE Sensors Journal.

[17]  V. Mágori Ultrasonic sensors in air , 1994, Proceedings - IEEE Ultrasonics Symposium.

[18]  A. Nikoozadeh,et al.  An integrated circuit with transmit beamforming flip-chip bonded to a 2-D CMUT array for 3-D ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  B. Khuri-Yakub,et al.  Fabrication of Capacitive Micromachined Ultrasonic Transducers via Local Oxidation and Direct Wafer Bonding , 2011, Journal of Microelectromechanical Systems.

[20]  Bernhard E. Boser,et al.  IN-AIR ULTRASONIC RANGEFINDING AND ANGLE ESTIMATION USING AN ARRAY OF ALN MICROMACHINED TRANSDUCERS , 2012 .

[21]  Aya Kamaya,et al.  Three-dimensional photoacoustic imaging using a two-dimensional CMUT array , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  H. Carr,et al.  DEVELOPMENTS IN CAPACITIVE TRANSDUCERS , 1992 .

[23]  Mario Kupnik,et al.  FEA of CMUTs suitable for wide gas pressure range applications , 2010, 2010 IEEE International Ultrasonics Symposium.

[24]  B. Khuri-Yakub,et al.  A surface micromachined electrostatic ultrasonic air transducer , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  M. Kupnik,et al.  50 kHz capacitive micromachined ultrasonic transducers for generation of highly directional sound with parametric arrays , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[26]  B. Khuri-Yakub,et al.  Finite element analysis of stress stiffening effects in CMUTS , 2008, 2008 IEEE Ultrasonics Symposium.

[27]  Jørgen Arendt Jensen,et al.  Synthetic aperture ultrasound imaging. , 2006, Ultrasonics.

[28]  D A Hutchins,et al.  A conical air-coupled capacitance transducer for surface imaging. , 2003, Ultrasonics.

[29]  G Wade Human uses of ultrasound: ancient and modern. , 2000, Ultrasonics.