A Resistive Sensor Readout Circuit With Intrinsic Insensitivity to Circuit Parameters and Its Evaluation

A novel readout circuit for interfacing single element resistive sensors is presented in this paper. The proposed scheme is based on a new relaxation oscillator (RO). The RO, along with a timer counter provides a digital output proportional to the resistance of the sensor. The output characteristic of most of the existing readout circuits for resistive sensors suffers from gain, offset, and nonlinearity errors. The sources of errors include various nonideal circuit parameters and their drift. The output of the proposed readout circuit has a special feature that it is not a function of the circuit parameters such as: 1) offset voltages of the opamps and comparators; 2) bias currents of the opamps and comparators; 3) gain of various units employed; 4) ON-resistance of the switches; 5) value or mismatch in the magnitudes of the reference voltages employed; 6) delay of the switches and comparator; 7) leakage current of the switch; and 8) slew rate of the opamp. Such a scheme will be useful for high accuracy measurements, even when the parameters 1)–8) may vary or drift, due to variation in the measurement environment. A prototype of the proposed readout scheme has been developed in the laboratory and the performance has been evaluated under various conditions. The output was found to be linear with a worst-case nonlinearity of 0.05%. Test results from a prototype developed show that the proposed scheme possesses all the features, described above, as expected.

[1]  Ernesto Serrano-Finetti,et al.  Low-Power Direct Resistive Sensor-to-Microcontroller Interfaces , 2016, IEEE Transactions on Instrumentation and Measurement.

[2]  Ildon Guilherme Borchardt,et al.  Pseudo−bridge: a different way to compare resistances , 1975 .

[3]  Boby George,et al.  An Improved Direct Digital Converter for Bridge-Connected Resistive Sensors , 2016, IEEE Sensors Journal.

[4]  Boby George,et al.  Resistance-to-digital converter designed for high power-line interference rejection capability , 2017, IET Circuits Devices Syst..

[5]  Marco Crepaldi,et al.  A $0.13~\mu{\rm m}$ CMOS Operational Schmitt Trigger R-to-F Converter for Nanogap-Based Nanosensors Read-Out , 2013, IEEE Transactions on Circuits and Systems I: Regular Papers.

[6]  Catherine Dehollain,et al.  A 15 $\mu{\rm W}$ 5.5 kS/s Resistive Sensor Readout Circuit with 7.6 ENOB , 2014, IEEE Transactions on Circuits and Systems I: Regular Papers.

[7]  Li-Rong Zheng,et al.  A UWB-Based Sensor-to-Time Transmitter for RF-Powered Sensing Applications , 2016, IEEE Transactions on Circuits and Systems II: Express Briefs.

[8]  Walt Kester,et al.  The data conversion handbook , 2005 .

[9]  Boby George,et al.  A Novel Dual-Slope Resistance-to-Digital Converter , 2010, IEEE Transactions on Instrumentation and Measurement.

[10]  A. Flammini,et al.  A New Low-Cost Electronic System to Manage Resistive Sensors for Gas Detection , 2007, IEEE Sensors Journal.

[11]  Daniele Marioli,et al.  A low-cost interface to high-value resistive sensors varying over a wide range , 2004, IEEE Transactions on Instrumentation and Measurement.

[12]  Boby George,et al.  A Resistance-to-Digital Converter possessing exceptional insensitivity to circuit parameters , 2016, 2016 IEEE International Instrumentation and Measurement Technology Conference Proceedings.

[13]  S. Kaliyugavaradan A linear resistance-to-time converter with high resolution , 2000, IEEE Trans. Instrum. Meas..

[14]  T. Islam,et al.  Relaxation Oscillator-Based Active Bridge Circuit for Linearly Converting Resistance to Frequency of Resistive Sensor , 2013, IEEE Sensors Journal.

[15]  Boby George,et al.  Analysis of a Sigma–Delta Resistance-to-Digital Converter for Differential Resistive Sensors , 2009, IEEE Transactions on Instrumentation and Measurement.

[16]  Hoon Kim,et al.  A Resistance Deviation-to-Pulsewidth Converter for Resistive Sensors , 2004, IEEE Transactions on Instrumentation and Measurement.

[17]  D. J. Yonce,et al.  A DC autonulling bridge for real-time resistance measurement , 2000 .

[18]  Ramon Pallàs Areny,et al.  Compensation of impedance meters when using an external front-end amplifier , 2002 .

[19]  Wuqiang Yang,et al.  Performance analysis of a digital capacitance measuring circuit. , 2015, The Review of scientific instruments.