POCS‐enhanced inherent correction of motion‐induced phase errors (POCS‐ICE) for high‐resolution multishot diffusion MRI
暂无分享,去创建一个
Feng Huang | Zhe Zhang | Chun Yuan | Hua Guo | Xiaodong Ma | Bida Zhang | Zhe Zhang | F. Huang | C. Yuan | Hua Guo | Xiaodong Ma | Bida Zhang
[1] Trong-Kha Truong,et al. High‐resolution multishot spiral diffusion tensor imaging with inherent correction of motion‐induced phase errors , 2014, Magnetic resonance in medicine.
[2] J C Gore,et al. Analysis and correction of motion artifacts in diffusion weighted imaging , 1994, Magnetic resonance in medicine.
[3] J. Pauly,et al. Isotropic diffusion‐weighted and spiral‐navigated interleaved EPI for routine imaging of acute stroke , 1997, Magnetic resonance in medicine.
[4] W. Manning,et al. Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays , 1997, Magnetic resonance in medicine.
[5] Robin M Heidemann,et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.
[6] Allen W. Song,et al. A robust multi-shot scan strategy for high-resolution diffusion weighted MRI enabled by multiplexed sensitivity-encoding (MUSE) , 2013, NeuroImage.
[7] John M. Pauly,et al. Improved automatic off‐resonance correction without a field map in spiral imaging , 1997, Magnetic resonance in medicine.
[8] Jens Frahm,et al. Inverse reconstruction method for segmented multishot diffusion‐weighted MRI with multiple coils , 2009, Magnetic resonance in medicine.
[9] M. Moseley,et al. Self‐navigated interleaved spiral (SNAILS): Application to high‐resolution diffusion tensor imaging , 2004, Magnetic resonance in medicine.
[10] Roland Bammer,et al. New methods in diffusion-weighted and diffusion tensor imaging. , 2009, Magnetic resonance imaging clinics of North America.
[11] R. Gerchberg. A practical algorithm for the determination of phase from image and diffraction plane pictures , 1972 .
[12] Bin Chen,et al. Correction for direction-dependent distortions in diffusion tensor imaging using matched magnetic field maps , 2006, NeuroImage.
[13] Roland Bammer,et al. Diffusion tensor imaging using single‐shot SENSE‐EPI , 2002, Magnetic resonance in medicine.
[14] R. Stollberger,et al. Improved diffusion‐weighted single‐shot echo‐planar imaging (EPI) in stroke using sensitivity encoding (SENSE) , 2001, Magnetic resonance in medicine.
[15] Bida Zhang,et al. Convergence behavior of iterative SENSE reconstruction with non‐Cartesian trajectories , 2005, Magnetic resonance in medicine.
[16] F. Huang,et al. Parallel imaging and compressed sensing combined framework for accelerating high‐resolution diffusion tensor imaging using inter‐image correlation , 2015, Magnetic resonance in medicine.
[17] P. Jezzard,et al. Correction for geometric distortion in echo planar images from B0 field variations , 1995, Magnetic resonance in medicine.
[18] Walter F Block,et al. POCS‐enhanced correction of motion artifacts in parallel MRI , 2010, Magnetic resonance in medicine.
[19] Peter R. Luijten,et al. Diffusion-weighted whole-body imaging with background body signal suppression (DWIBS): features and potential applications in oncology , 2008, European Radiology.
[20] Douglas C. Noll,et al. Deblurring for non‐2D fourier transform magnetic resonance imaging , 1992, Magnetic resonance in medicine.
[21] Jeffrey A. Fessler,et al. Nonuniform fast Fourier transforms using min-max interpolation , 2003, IEEE Trans. Signal Process..
[22] D. Youla,et al. Image Restoration by the Method of Convex Projections: Part 1ߞTheory , 1982, IEEE Transactions on Medical Imaging.
[23] P Wach,et al. Diffusion-weighted imaging with navigated interleaved echo-planar imaging and a conventional gradient system. , 1999, Radiology.
[24] Stefan Skare,et al. Clinical multishot DW‐EPI through parallel imaging with considerations of susceptibility, motion, and noise , 2007, Magnetic resonance in medicine.
[25] R R Edelman,et al. Functional imaging of the kidney by means of measurement of the apparent diffusion coefficient. , 1994, Radiology.
[26] P. V. van Zijl,et al. Three‐dimensional tracking of axonal projections in the brain by magnetic resonance imaging , 1999, Annals of neurology.
[27] A. Macovski,et al. Selection of a convolution function for Fourier inversion using gridding [computerised tomography application]. , 1991, IEEE transactions on medical imaging.
[28] John C Gore,et al. High‐resolution human diffusion tensor imaging using 2‐D navigated multishot SENSE EPI at 7 T , 2013, Magnetic resonance in medicine.
[29] Hua Guo,et al. POCS-ICE : POCS based Inherent Correction of phase Errors for multi-shot spiral DWI , 2013 .
[30] P. Roemer,et al. The NMR phased array , 1990, Magnetic resonance in medicine.
[31] Ying-Hui Chou,et al. Interleaved EPI Based fMRI Improved by Integration of Multiplexed Sensitivity Encoding ( MUSE ) and Simultaneous Multi-band Imaging , 2013 .
[32] M Hedley,et al. Motion artifact correction in MRI using generalized projections. , 1991, IEEE transactions on medical imaging.
[33] Karla L Miller,et al. Nonlinear phase correction for navigated diffusion imaging , 2003, Magnetic resonance in medicine.
[34] David Atkinson,et al. Nonlinear phase correction of navigated multi‐coil diffusion images , 2006, Magnetic resonance in medicine.
[35] P. Boesiger,et al. SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.
[36] A. Connelly,et al. Sampling and reconstruction effects due to motion in diffusion‐weighted interleaved echo planar imaging , 2000, Magnetic resonance in medicine.
[37] Hangyi Jiang,et al. DtiStudio: Resource program for diffusion tensor computation and fiber bundle tracking , 2006, Comput. Methods Programs Biomed..
[38] R. Turner,et al. Layer-Specific Intracortical Connectivity Revealed with Diffusion MRI , 2012, Cerebral cortex.
[39] P. Basser,et al. MR diffusion tensor spectroscopy and imaging. , 1994, Biophysical journal.
[40] P. Bhattacharya. Diffusion MRI: Theory, methods, and applications, Derek K. Jones (Ed.). Oxford University press (2011), $152.77 , 2012 .
[41] Bo Liu,et al. A statistical approach to SENSE regularization with arbitrary k‐space trajectories , 2008, Magnetic resonance in medicine.
[42] Junfeng Yang,et al. A New Alternating Minimization Algorithm for Total Variation Image Reconstruction , 2008, SIAM J. Imaging Sci..
[43] Chris R. Johnson,et al. POCSENSE: POCS‐based reconstruction for sensitivity encoded magnetic resonance imaging , 2004, Magnetic resonance in medicine.
[44] J. Pauly,et al. Diffusion‐weighted interleaved echo‐planar imaging with a pair of orthogonal navigator echoes , 1996, Magnetic resonance in medicine.
[45] James G Pipe,et al. Multishot diffusion‐weighted FSE using PROPELLER MRI , 2002, Magnetic resonance in medicine.
[46] S. Skare,et al. Readout-segmented EPI for rapid high resolution diffusion imaging at 3 T. , 2008, European journal of radiology.
[47] Trong-Kha Truong,et al. Inherent correction of motion‐induced phase errors in multishot spiral diffusion‐weighted imaging , 2012, Magnetic resonance in medicine.
[48] R L O'Halloran,et al. Model for the correction of motion‐induced phase errors in multishot diffusion‐weighted‐MRI of the head: Are cardiac‐motion‐induced phase errors reproducible from beat‐to‐beat? , 2012, Magnetic resonance in medicine.