A model and method to determine solar extinction coefficient of aerogel granules layer through experiment under real climatic condition

Abstract Solar extinction coefficient is an important parameter in simulating the thermal and energy performances of glazing, but it is difficult to obtain the solar extinction coefficient of aerogel granules layer (SECAL) due to its nano-porous network structure. In this study, an in-field test room is built to measure the irradiance at both sides of granular nano-porous silica aerogel glazing system under different climatic conditions. The SECAL is estimated through an optical model and mathematical methodology from the measurement data. The optical model is proposed on the base of interface energy balance principle, in which the incident angle and scattering phenomena happening in the nano-porous silica aerogel are taken into account. Through the optical model, the irradiation transmittance is calculated by an assumed SECAL value and indoor irradiance is predicted. The SECAL value is estimated by finding the minimal error between the predicted and measured indoor irradiance. The SECAL values for clear and overcast sky are respectively obtained, and the values are 0.0392/mm and 0.0296/mm respectively. Sky clearness factor is used as the index of weather condition to select the SECAL values. The optical model and methodology is valid to determine SECAL and the optical model is accurate to calculate solar irradiance through aerogel glazing system.

[1]  R. Pekala,et al.  Thermal Conductivity of Monolithic Organic Aerogels , 1992, Science.

[2]  Umberto Berardi,et al.  The development of a monolithic aerogel glazed window for an energy retrofitting project , 2015 .

[3]  Dominique Baillis,et al.  Experimental Determination and Modeling of the Radiative Properties of Silica Nanoporous Matrices , 2009 .

[4]  M. Ayers,et al.  Effective optical constants n and κ and extinction coefficient of silica aerogel , 1996 .

[5]  Bjørn Petter Jelle,et al.  Perspective of aerogel glazings in energy efficient buildings , 2016 .

[6]  Taehoon Hong,et al.  LCC and LCCO2 analysis of green roofs in elementary schools with energy saving measures , 2012 .

[7]  Dong Liu,et al.  Calculation and experimental validation of spectral properties of microsize grains surrounded by nanoparticles. , 2014, Optics express.

[8]  Huijun Wu,et al.  Quantitative research on the influence of particle size and filling thickness on aerogel glazing performance , 2018, Energy and Buildings.

[9]  Yang Liu,et al.  Solar Extinction Coefficient of Silica Aerogel Calculated through Integral Model and Experimental Data , 2017 .

[10]  Mark Z. Jacobson,et al.  Fundamentals of atmospheric modeling , 1998 .

[11]  Arild Gustavsen,et al.  Key elements of and material performance targets for highly insulating window frames , 2011 .

[12]  D. Saheb-Koussa,et al.  Experimental investigation of simple solar radiation spectral model performances under a Mediterranean Algerian's climate , 2017 .

[13]  P. Ineichen,et al.  A new simplified version of the perez diffuse irradiance model for tilted surfaces , 1987 .

[14]  Tore Kolås Performance of Daylight Redirecting Venetian Blinds for Sidelighted Spaces at High Latitudes , 2013 .

[15]  Arild Gustavsen,et al.  Aerogel granulate glazing facades and their application potential from an energy saving perspective , 2015 .

[16]  Jianlei Niu,et al.  Energy and visual performance of the silica aerogel glazing system in commercial buildings of Hong Kong , 2015 .

[17]  C. Gueymard The sun's total and spectral irradiance for solar energy applications and solar radiation models , 2004 .

[18]  X. Wang,et al.  A simplified model exploration research of new anisotropic diffuse radiation model , 2016 .

[19]  Valentina Serra,et al.  A numerical model to evaluate the thermal behaviour of active transparent façades , 2011 .

[20]  Cinzia Buratti,et al.  Experimental performance evaluation of aerogel glazing systems , 2012 .

[21]  A. G. Caldwell,et al.  Thermal Conductivity of Silica Aërogel , 1934 .

[22]  G. Tang,et al.  Numerical study of radiative properties of nanoporous silica aerogel , 2015 .

[23]  Dong Liu,et al.  Theoretical model of radiative transfer in opacified aerogel based on realistic microstructures , 2014 .

[24]  Jianlei Niu,et al.  Application of super-insulating translucent silica aerogel glazing system on commercial building envelope of humid subtropical climates - Impact on space cooling load , 2015 .

[25]  Jianlei Niu,et al.  Study on performance of energy-efficient retrofitting measures on commercial building external walls in cooling-dominant cities , 2013 .

[26]  Saffa Riffat,et al.  A state-of-the-art review on innovative glazing technologies , 2015 .

[27]  N. D. Kaushika,et al.  Solar transparent insulation materials: a review , 2003 .

[28]  Xiaoze Du,et al.  Radiative heat transfer study on silica aerogel and its composite insulation materials , 2013 .

[29]  R. Gayathri,et al.  Golden section search based maximum power point tracking strategy for a dual output DC-DC converter , 2016, Ain Shams Engineering Journal.