Spot size and quality of scanning laser correction of higher order wavefront aberrations.

PURPOSE To investigate the effect of laser spot size on the outcome of aberration correction with scanning laser corneal ablation. METHODS Numerical simulation of ablation outcome. RESULTS Correction of wavefront aberrations of Zernike modes from second to eighth order were simulated. Gaussian and top-hat beams of 0.6 to 2.0-mm full-width-half-maximum diameters were modeled. The fractional correction and secondary aberration (distortion) were evaluated. Using a distortion/correction ratio of less than 0.5 as a cutoff for adequate performance, we found that a 2 mm or smaller beam is adequate for spherocylindrical correction (Zernike second order), a 1 mm or smaller beam is adequate for correction of up to fourth order Zernike modes, and a 0.6 mm or smaller beam is adequate for correction of up to sixth order Zernike modes. CONCLUSIONS Since ocular aberrations above Zernike fourth order are relatively insignificant, current scanning lasers with a beam diameter of 1 mm or less are theoretically capable of eliminating most of the higher order aberrations of the eye.

[1]  Junzhong Liang,et al.  Aberrations and retinal image quality of the normal human eye. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[2]  S. Trokel,et al.  Corneal ablation profilometry and steep central islands. , 1997, Journal of refractive surgery.

[3]  T Seiler,et al.  Limitations of erbium:YAG laser photorefractive keratectomy. , 2000, Journal of refractive surgery.

[4]  J. Alió,et al.  Selective zonal ablations with excimer laser for correction of irregular astigmatism induced by refractive surgery. , 2000, Ophthalmology.

[5]  G. Alessio,et al.  Topography-driven photorefractive keratectomy: results of corneal interactive programmed topographic ablation software. , 2000, Ophthalmology.

[6]  J. Y. Wang,et al.  Wave-front interpretation with Zernike polynomials. , 1980, Applied optics.

[7]  H R Taylor,et al.  Prevalence of central islands after excimer laser refractive surgery , 1995, Journal of cataract and refractive surgery.

[8]  S M MacRae,et al.  Supernormal vision, hypervision, and customized corneal ablation. , 2000, Journal of cataract and refractive surgery.

[9]  C. McGhee,et al.  Natural history of central topographic islands following excimer laser photorefractive keratectomy , 1996, Journal of cataract and refractive surgery.

[10]  G. E. Tamayo Fernandez,et al.  Early clinical experience using custom excimer laser ablations to treat irregular astigmatism , 2000, Journal of cataract and refractive surgery.

[11]  M. Kitai,et al.  The physics of UV laser cornea ablation , 1991 .

[12]  D R Williams,et al.  Supernormal vision and high-resolution retinal imaging through adaptive optics. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[13]  M. Knorz,et al.  Laser in situ keratomileusis assisted by corneal topography , 1998, Journal of cataract and refractive surgery.

[14]  D. Lieberman,et al.  A mathematical model for laser in situ keratomileusis and photorefractive keratectomy. , 2000, Journal of refractive surgery.

[15]  T Seiler,et al.  Excimer laser photorefractive keratectomy. , 1995, Survey of ophthalmology.

[16]  M. Knorz,et al.  Topographically-guided laser in situ keratomileusis to treat corneal irregularities. , 2000, Ophthalmology.

[17]  E Schröder,et al.  Topography-controlled excimer laser photorefractive keratectomy. , 2000, Journal of refractive surgery.

[18]  L. Thibos,et al.  Standards for reporting the optical aberrations of eyes. , 2002, Journal of refractive surgery.

[19]  J. M. Miller,et al.  Representation of videokeratoscopic height data with Zernike polynomials. , 1995, Journal of the Optical Society of America. A, Optics, image science, and vision.

[20]  R R Krueger,et al.  Quantitation of corneal ablation by ultraviolet laser light. , 1985, Archives of ophthalmology.