Microelectrochemical enzyme transistors, or enzyme switches, were prepared by connecting two carbon band electrodes (∼10 μm wide, 4.5 mm long separated by a 20-μm gap) with an anodically grown film of poly(aniline). Glucose oxidase (GOx, EC 1.1.3.4) was immobilized onto the poly(aniline) film in an insulating poly(1,2-diaminobenzene) polymer grown electro-chemically on top of the poly(aniline) film to complete the device

[1]  Adam Heller,et al.  Direct electrical communication between chemically modified enzymes and metal electrodes. I. Electron transfer from glucose oxidase to metal electrodes via electron relays, bound covalently to the enzyme , 1987 .

[2]  M. Natan,et al.  Modification of microelectrode arrays: new microelectrochemical devices for sensor applications , 1986 .

[3]  D. Bélanger,et al.  Electrochemistry of the polypyrrole glucose oxidase electrode , 1989 .

[4]  R. Lal,et al.  A biosensor based on conducting polymers , 1992 .

[5]  Laurence M. Peter,et al.  Microelectrode studies of fast switching in polyaniline films , 1989 .

[6]  C. Lowe,et al.  Immobilization of glucose oxidase in ferrocene-modified pyrrole polymers. , 1988, Analytical chemistry.

[7]  P. N. Bartlett,et al.  Correction - Electrochemical Immobilization of Enzymes. 3. Immobilization of Glucose Oxidase in Thin Films on Electrochemically Polymerized Phenols , 1992 .

[8]  L. Nyholm,et al.  Redox switching of polyaniline films: Low temperature studies , 1993 .

[9]  L. Nyholm,et al.  Chronopotentiometric studies of polyaniline films , 1992 .

[10]  P. Trinder,et al.  An improved colour reagent for the determination of blood glucose by the oxidase system. , 1972, The Analyst.

[11]  D. Buttry,et al.  Determination of ion populations and solvent content as functions of redox state and pH in polyaniline , 1987 .

[12]  Philip N. Bartlett,et al.  ENZYME SWITCH RESPONSIVE TO GLUCOSE , 1993 .

[13]  James W. Thackeray,et al.  Chemically responsive microelectrochemical devices based on platinized poly(3-methylthiophene): variation in conductivity with variation in hydrogen, oxygen, or pH in aqueous solution , 1986 .

[14]  Antonio J. Ricco,et al.  Resistance of polyaniline films as a function of electrochemical potential and the fabrication of polyaniline-based microelectronic devices , 1985 .

[15]  Henry S. White,et al.  Chemical derivatization of an array of three gold microelectrodes with polypyrrole: Fabrication of a molecule-based transistor , 1984 .

[16]  James W. Thackeray,et al.  Poly(3-methylthiophene)-coated electrodes: optical and electrical properties as a function of redox potential and amplification of electrical and chemical signals using poly(3-methylthiophene)-based microelectrochemical transistors , 1985 .

[17]  I Uchida,et al.  Penicillin sensor based on a microarray electrode coated with pH-responsive polypyrrole. , 1992, Analytical chemistry.

[18]  Sze‐cheng Yang,et al.  Influence of oxidation and protonation on the electrical conductivity of polyaniline , 1987 .

[19]  H. White,et al.  A microelectrochemical diode with submicron contact spacing based on the connection of two microelectrodes using dissimilar redox polymers , 1985 .

[20]  Matsuhiko Nishizawa,et al.  An enzyme switch sensitive to NADH , 1991 .

[21]  L. Nyholm,et al.  Microelectrode studies of the switching of polyaniline films in unbuffered and buffered solutions , 1993 .

[22]  B. C. Webb,et al.  Response of an enzyme-modified pH-sensitive ion-selective device; experimental study of a glucose oxidase-modified ion-sensitive field effect transistor in buffered and unbuffered aqueous solution , 1985 .

[23]  P. Bartlett,et al.  The application of conducting polymers in biosensors , 1993 .