A Thorax Simulator for Complex Dynamic Bioimpedance Measurements With Textile Electrodes

Bioimpedance measurements on the human thorax are suitable for assessment of body composition or hemodynamic parameters, such as stroke volume; they are non-invasive, easy in application and inexpensive. When targeting personal healthcare scenarios, the technology can be integrated into textiles to increase ease, comfort and coverage of measurements. Bioimpedance is generally measured using two electrodes injecting low alternating currents (0.5-10 mA) and two additional electrodes to measure the corresponding voltage drop. The impedance is measured either spectroscopically (bioimpedance spectroscopy, BIS) between 5 kHz and 1 MHz or continuously at a fixed frequency around 100 kHz (impedance cardiography, ICG). A thorax simulator is being developed for testing and calibration of bioimpedance devices and other new developments. For the first time, it is possible to mimic the complete time-variant properties of the thorax during an impedance measurement. This includes the dynamic real part and dynamic imaginary part of the impedance with a peak-to-peak value of 0.2 Ω and an adjustable base impedance (24.6 Ω ≥ Z0 ≥ 51.6 Ω). Another novelty is adjustable complex electrode-skin contact impedances for up to 8 electrodes to evaluate bioimpedance devices in combination with textile electrodes. In addition, an electrocardiographic signal is provided for cardiographic measurements which is used in ICG devices. This provides the possibility to generate physiologic impedance changes, and in combination with an ECG, all parameters of interest such as stroke volume (SV), pre-ejection period (PEP) or extracellular resistance (Re) can be simulated. The speed of all dynamic signals can be altered. The simulator was successfully tested with commercially available BIS and ICG devices and the preset signals are measured with high correlation (r = 0.996).

[1]  Wenjun Hu,et al.  A study on methods for impedance cardiography , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[2]  H. Schwan Electrical properties of tissue and cell suspensions. , 1957, Advances in biological and medical physics.

[3]  Paulo Carvalho,et al.  Robust Characteristic Points for ICG - Definition and Comparative Analysis , 2011, BIOSIGNALS.

[4]  Prem C. Pandey,et al.  Thoracic Simulator for Impedance Cardiography , 2003 .

[5]  P. Squara,et al.  Bioreactance: A New Method for Non-invasive Cardiac Output Monitoring , 2008 .

[6]  S. Leonhardt,et al.  Simulation of lung edema in impedance cardiography , 2012, 2012 Computing in Cardiology.

[7]  Eung Je Woo,et al.  Nanofiber Web Textile Dry Electrodes for Long-Term Biopotential Recording , 2013, IEEE Transactions on Biomedical Circuits and Systems.

[8]  O. Alata,et al.  Impedance cardiography filtering using scale fourier linear combiner based on RLS algorithm , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  Prem C. Pandey,et al.  Impedance Simulator for Testing of Instruments for Bioimpedance Sensing , 2008 .

[10]  Prem C. Pandey,et al.  A microcontroller based thorax simulator for testing and calibration of impedance cardiographs , 2009 .

[11]  Donald P. Bernstein,et al.  Stroke volume equation for impedance cardiography , 2005, Medical and Biological Engineering and Computing.

[12]  L. Ward,et al.  Multiple frequency bioelectrical impedance analysis: a cross-validation study of the inductor circuit and Cole models. , 1999, Physiological measurement.

[13]  S. Leonhardt,et al.  Characterization of textile electrodes and conductors using standardized measurement setups , 2010, Physiological measurement.

[14]  R. Vogel,et al.  Impedance cardiography: the next vital sign technology? , 2003, Chest.

[15]  L. Critchley,et al.  Impedance cardiographyThe impact of new technology , 1998, Anaesthesia.

[16]  Sverre Grimnes,et al.  Bioimpedance and Bioelectricity Basics , 2000 .

[17]  Paulo Carvalho,et al.  Cardiac status assessment with a multi-signal device for improved home-based congestive heart failure management , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[18]  Thomas W. Kamarck,et al.  Stability of cardiac impedance measures: Aortic opening (B-point) detection and scoring , 1993, Biological Psychology.

[19]  John H. Busser,et al.  Principles of Applied Biomedical Instrumentation , 1968 .