Material fundamentals and clinical performance of plasma-sprayed hydroxyapatite coatings: a review.
暂无分享,去创建一个
K A Gross | L Sun | C. Berndt | K. Gross | Limin Sun | A. Kucuk | C C Berndt | A Kucuk | L. Sun | L. Sun
[1] J. F. Kay. A new concept for noncement fixation of orthopaedic devices , 1987 .
[2] W. E. Brown,et al. Crystallographic studies of the role of Mg as a stabilizing impurity in β-Ca3(PO4)2. The crystal structure of pure β-Ca3(PO4)2 , 1974 .
[3] P Ducheyne,et al. Bioactive ceramic prosthetic coatings. , 1992, Clinical orthopaedics and related research.
[4] P. Ducheyne,et al. Auger Electron Spectroscopic Analysis of Hydroxylapatite Coatings on Titanium , 1984 .
[5] Block Ms,et al. Prospective review of integral implants. , 1992 .
[6] B. C. Wang,et al. Changes in phases and crystallinity of plasma-sprayed hydroxyapatite coatings under heat treatment: a quantitative study. , 1995, Journal of biomedical materials research.
[7] S. Toksvig-Larsen,et al. Hydroxyapatite-Enhanced Tibial Prosthetic Fixation , 2000, Clinical orthopaedics and related research.
[8] E. Morscher. Hydroxyapatite coating of prostheses. , 1991, The Journal of bone and joint surgery. British volume.
[9] R. Huiskes. The various stress patterns of press-fit, ingrown, and cemented femoral stems. , 1990, Clinical orthopaedics and related research.
[10] Jui-Che Lin,et al. Ex-vivo blood compatibility of silicone-containing biomaterials , 1994 .
[11] A. Tonino,et al. Hydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem. , 1999, The Journal of bone and joint surgery. British volume.
[12] G. Papanicolaou,et al. Engineering Applications of New Composites , 1988 .
[13] G. Magyar,et al. Hydroxyapatite coating of threaded pins enhances fixation. , 1997, The Journal of bone and joint surgery. British volume.
[14] J N Kent,et al. Biointegrated hydroxylapatite-coated dental implants: 5-year clinical observations. , 1990, Journal of the American Dental Association.
[15] D. Scott,et al. Current Concepts Review - Total Hip Arthroplasty with Hydroxyapatite-Coated Prostheses* , 1996 .
[16] R. Bloebaum,et al. Osteolysis from a press-fit hydroxyapatite-coated implant. A case study. , 1993, The Journal of arthroplasty.
[17] A. Cigada,et al. Adhesion properties of plasma sprayed hydroxylapatite coatings for orthopaedic prostheses. , 1993, Bio-medical materials and engineering.
[18] M. Røkkum,et al. Polyethylene wear, osteolysis and acetabular loosening with an HA-coated hip prosthesis , 1999 .
[19] J D Haman,et al. Characterization of high velocity oxy-fuel combustion sprayed hydroxyapatite. , 1995, Biomaterials.
[20] M. Freeman,et al. Hydroxyapatite coating of an acetabular prosthesis. Effect on stability. , 1996, The Journal of bone and joint surgery. British volume.
[21] H. Oonishi,et al. The effect of hydroxyapatite coating on bone growth into porous titanium alloy implants. , 1989, The Journal of bone and joint surgery. British volume.
[22] W. Capello,et al. Remodeling of Bone around Hydroxyapatite-Coated Femoral Stems* , 1996, The Journal of bone and joint surgery. American volume.
[23] U. Pazzaglia,et al. Thermal behaviour of hydroxyapatite intended for medical applications. , 1993, Biomaterials.
[24] C. Doyle,et al. Plasma sprayed hydroxyapatite coatings on titanium substrates. Part 1: Mechanical properties and residual stress levels. , 1998, Biomaterials.
[25] C. Klein,et al. Chemical implant fixation using hydroxyl-apatite coatings. The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates. , 1987, Clinical orthopaedics and related research.
[26] K. Bachus,et al. Mineral apposition rates of human cancellous bone at the interface of porous coated implants. , 1994, Journal of biomedical materials research.
[27] S. Radin,et al. The effect of calcium phosphate ceramic composition and structure on in vitro behavior. I. Dissolution. , 1993, Journal of biomedical materials research.
[28] R. Geesink,et al. Six-year results of hydroxyapatite-coated total hip replacement. , 1995, The Journal of bone and joint surgery. British volume.
[29] A. Tonino,et al. Hydroxyapatite-coated femoral stems , 1999 .
[30] I. Turner,et al. Residual stress measurement in thermal sprayed hydroxyapatite coatings , 1994 .
[31] Newman Mg,et al. A study of in vitro attachment of Streptococcus sanguis and Actinomyces viscosus to saliva-treated titanium. , 1989 .
[32] H. Aoki,et al. Mechanical properties of sintered hydroxyapatite for prosthetic applications , 1981 .
[33] P. Ducheyne,et al. The effect of plasma-sprayed calcium phosphate ceramic coatings on the metal ion release from porous titanium and cobalt-chromium alloys. , 1988, Journal of biomedical materials research.
[34] J. Osborn,et al. Fixation of hip prostheses by hydroxyapatite ceramic coatings. , 1991, The Journal of bone and joint surgery. British volume.
[35] J. Kärrholm,et al. Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. , 1994, The Journal of bone and joint surgery. British volume.
[36] D R Sumner,et al. A quantitative study of bone and soft tissues in cementless porous-coated acetabular components retrieved at autopsy. , 1993, The Journal of arthroplasty.
[37] P. Ducheyne,et al. Effect of hydroxyapatite impregnation on skeletal bonding of porous coated implants. , 1980, Journal of biomedical materials research.
[38] W H Harris,et al. Localized osteolysis in stable, non-septic total hip replacement. , 1986, The Journal of bone and joint surgery. American volume.
[39] J. Besjakov,et al. Migration and wear of a hydroxyapatite-coated hip prosthesis. A controlled roentgen stereophotogrammetric study. , 1996, The Journal of bone and joint surgery. British volume.
[40] W. Maloney,et al. The progression of femoral cortical osteolysis in association with total hip arthroplasty without cement. , 1992, The Journal of bone and joint surgery. American volume.
[41] W. Bonfield,et al. Hydroxyapatite reinforced polyethylene--a mechanically compatible implant material for bone replacement. , 1981, Biomaterials.
[42] B. Kiratli,et al. Measurement of bone mineral density by dual-energy x-ray absorptiometry in patients with the Wisconsin hip, an uncemented femoral stem. , 1996, The Journal of arthroplasty.
[43] M. Yoshinari,et al. Thin hydroxyapatite coating produced by the ion beam dynamic mixing method. , 1994, Biomaterials.
[44] P. Delincé,et al. [Histological analysis of the bone/prosthesis interface in man after implantation of a hip prosthesis coated with plasma-sprayed hydroxyapatite]. , 1993, Revue de chirurgie orthopedique et reparatrice de l'appareil moteur.
[45] G. Chang,et al. Intramedullary implant of plasma-sprayed hydroxyapatite coating: an interface study. , 1997, Journal of biomedical materials research.
[46] J. Kärrholm,et al. Early failure of hydroxyapatite-coating in total knee arthroplasty. A case report. , 1994, Acta orthopaedica Scandinavica.
[47] D. Scott,et al. Total hip arthroplasty with hydroxyapatite-coated prostheses. , 1996, The Journal of bone and joint surgery. American volume.
[48] T. Nieh,et al. Preparing hydroxyapatite powders with controlled morphology. , 1996, Biomaterials.
[49] J. Gantenberg,et al. Calcium Phosphate (Ca-P) Coating Draft Guidance for Preparation of Food and Drug Administration (FDA) Submissions for Orthopedic and Dental Endosseous Implants , 1994 .
[50] B. C. Wang,et al. Plasma spraying of zirconia-reinforced hydroxyapatite composite coatings on titanium: Part II Dissolution behaviour in simulated body fluid and bonding degradation , 1997, Journal of materials science. Materials in medicine.
[51] M A Freeman,et al. Early migration and late aseptic failure of proximal femoral prostheses. , 1994, The Journal of bone and joint surgery. British volume.
[52] U. Aebi,et al. Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating. , 1998, The Journal of bone and joint surgery. British volume.
[53] W. Harris,et al. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. , 1969, The Journal of bone and joint surgery. American volume.
[54] C. Cobb,et al. Microbial colonization on natural tooth structure compared with smooth and plasma-sprayed dental implant surfaces. , 1993, Clinical oral implants research.
[55] S. Green,et al. Chronic osteomyelitis in pin tracks. , 1984, The Journal of bone and joint surgery. American volume.
[56] E. Chao,et al. Cortical bone reactions at the interface of external fixation half-pins under different loading conditions. , 1993, The Journal of trauma.
[57] L. Dorr,et al. Complications with hydroxyapatite particulate separation in total hip arthroplasty. , 1994, Clinical orthopaedics and related research.
[58] I. Hvid,et al. Gap healing enhanced by hydroxyapatite coating in dogs. , 1991, Clinical orthopaedics and related research.
[59] D. Puleo,et al. Understanding and controlling the bone-implant interface. , 1999, Biomaterials.
[60] W. Hozack,et al. Hydroxyapatite-Coated Femoral Stems. A Matched-Pair Analysis of Coated and Uncoated Implants* , 1996, The Journal of bone and joint surgery. American volume.
[61] L. Hench,et al. Mechanical properties of bioactive glasses, glass-ceramics and composites , 1998, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[62] Paul Ducheyne,et al. Bioceramics: material characteristics versus in vivo behavior. , 1987, Journal of biomedical materials research.
[63] W. Maloney,et al. Increasing incidence of femoral osteolysis in association with uncemented Harris-Galante total hip arthroplasty. A follow-up report. , 1996, The Journal of arthroplasty.
[64] M. Dunn,et al. In vitro evaluation of amorphous calcium phosphate and poorly crystallized hydroxyapatite coatings on titanium implants. , 1993, Journal of biomedical materials research.
[65] Christopher C. Berndt,et al. Thermal spraying for bioceramic applications , 1990 .
[66] C. Engh,et al. Patterns of osteolysis around total hip components inserted with and without cement. , 1995, The Journal of bone and joint surgery. American volume.
[67] W. E. Brown,et al. Ca4(PO4)2O, tetracalcium diphosphate monoxide. Crystal structure and relationships to Ca5(PO4)3OH and K3Na(SO4)2 , 1973 .
[68] I. Pinder,et al. Results of uncemented porous-coated anatomic total hip replacement. , 1994, The Journal of bone and joint surgery. British volume.
[69] Michael Jarcho,et al. Calcium phosphate ceramics as hard tissue prosthetics. , 1981, Clinical orthopaedics and related research.
[70] A. S. Posner,et al. Crystal Structure of Hydroxyapatite , 1964, Nature.
[71] K. Bachus,et al. Determining mineral content variations in bone using backscattered electron imaging. , 1997, Bone.
[72] A. Moroni,et al. Hydroxyapatite coated external fixation pins: an experimental study. , 1996, Clinical orthopaedics and related research.
[73] J. Maltha,et al. Mandibular bone response to plasma-sprayed coatings of hydroxyapatite. , 1990, The International journal of prosthodontics.
[74] H. Skinner,et al. Current concepts in orthopaedic biomaterials and implant fixation. , 1993, Instructional course lectures.
[75] T. Bauer,et al. Uncemented acetabular components. Histologic analysis of retrieved hydroxyapatite-coated and porous implants. , 1993, The Journal of arthroplasty.
[76] P. Delincé,et al. Bonding of hydroxyapatite-coated femoral prostheses. Histopathology of specimens from four cases. , 1991, The Journal of bone and joint surgery. British volume.
[77] R Z LeGeros,et al. Biodegradation and bioresorption of calcium phosphate ceramics. , 1993, Clinical materials.
[78] W H Harris,et al. Differential effects of different forms of hydroxyapatite and hydroxyapatite/tricalcium phosphate particulates on human monocyte/macrophages in vitro. , 1996, Journal of biomedical materials research.
[79] H Weinans,et al. Adaptive bone remodeling and biomechanical design considerations for noncemented total hip arthroplasty. , 1989, Orthopedics.
[80] K. Hayashi,et al. Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength. , 1994, Biomaterials.
[81] M. Freeman,et al. The effect of hydroxyapatite coating on ingrowth of bone into cavities in an implant. , 1991, The Journal of arthroplasty.
[82] M. Dunn,et al. Mechanical and histological evaluation of amorphous calcium phosphate and poorly crystallized hydroxyapatite coatings on titanium implants. , 1993, Journal of Biomedical Materials Research.
[83] Donald L. Wise,et al. Encyclopedic Handbook of Biomaterials and Bioengineering , 1995 .
[84] C. Klein,et al. Plasma sprayed coatings of hydroxylapatite. , 1987, Journal of biomedical materials research.
[85] Rolando Barbucci,et al. Biological Performance of Materials , 2000 .
[86] L. Dorr,et al. Bilateral total hip arthroplasty comparing hydroxyapatite coating to porous-coated fixation. , 1998, The Journal of arthroplasty.
[87] J. Jansen,et al. Development of a new percutaneous access device for implantation in soft tissues. , 1991, Journal of biomedical materials research.
[88] R. C. Weast. CRC Handbook of Chemistry and Physics , 1973 .
[89] Howard J. Sanders,et al. High-tech ceramics , 1984 .
[90] R G Geesink,et al. Experimental and clinical experience with hydroxyapatite-coated hip implants. , 1989, Orthopedics.
[91] T. W. Roberts,et al. Clinical and microbiological findings on newly inserted hydroxyapatite-coated and pure titanium human dental implants. , 1991, Clinical oral implants research.
[92] C. Berndt,et al. Evaluation of microhardness and elastic modulus of thermally sprayed nanostructured zirconia coatings , 2001 .
[93] A. Bentur. The Pore Structure of Hydrated Cementitious Compounds of Different Chemical Composition , 1980 .
[94] A. Biesbrock,et al. Evaluation of the clinical predictability of hydroxyapatite-coated endosseous dental implants: a review of the literature. , 1995, The International journal of oral & maxillofacial implants.
[95] K. Hayashi,et al. Comparison of bone-implant interface shear strength of hydroxyapatite-coated and alumina-coated metal implants. , 1995, Journal of biomedical materials research.
[96] J. Ong,et al. Post-deposition heat treatments for ion beam sputter deposited calcium phosphate coatings. , 1994, Biomaterials.
[97] H. Aoki,et al. Hydroxyapatite coating by dipping method, and bone bonding strength , 1996 .
[98] W. Capello,et al. Hydroxylapatite‐Coated Hip Implants Multicenter Three‐Year Clinical and Roentgenographic Results , 1992, Clinical orthopaedics and related research.
[99] C. Klein,et al. Bonding of bone to apatite-coated implants. , 1988, The Journal of bone and joint surgery. British volume.
[100] S. Toksvig-Larsen,et al. Enhanced Fixation With Hydroxyapatite Coated Pins , 1998, Clinical orthopaedics and related research.
[101] P. Aspenberg,et al. Bone formation in the presence of phagocytosable hydroxyapatite particles. , 1994, Clinical orthopaedics and related research.
[102] R. Poss,et al. Catastrophic failure of the polyethylene liner of uncemented acetabular components. , 1994, The Journal of bone and joint surgery. British volume.
[103] C. Berndt,et al. Amorphous phase formation in plasma-sprayed hydroxyapatite coatings. , 1998, Journal of biomedical materials research.
[104] K. Gross,et al. The contribution of coating microstructure to degradation and particle release in hydroxyapatite coated prostheses. , 2002, Journal of biomedical materials research.
[105] P. Delincé,et al. Two-year outcome of hydroxyapatite-coated prostheses. Two femoral prostheses retrieved at autopsy. , 1994, Acta orthopaedica Scandinavica.
[106] D. Hoelzer,et al. Interfacial characterization of plasma-spray coated calcium phosphate on Ti–6Al–4V , 1998, Journal of materials science. Materials in medicine.
[107] P. Ducheyne,et al. Plasma spraying induced changes of calcium phosphate ceramic characteristics and the effect onin vitro stability , 1992 .
[108] R. Pilliar,et al. Characterization of the interface in the plasma-sprayed HA coating/Ti-6Al-4V implant system. , 1991, Journal of biomedical materials research.
[109] M. Freeman,et al. RADIOLOGICAL AND SURVIVAL COMPARISON OF FOUR METHODS OF FIXATION OF A PROXIMAL FEMORAL STEM , 1997 .
[110] M. Semlitsch. Titanium alloys for hip joint replacements , 1987 .
[111] C. Ju,et al. Structure and properties of hydroxyapatite-bioactive glass composites plasma sprayed on Ti6Al4V , 1994 .
[112] R G Geesink,et al. Hydroxyapatite-coated total hip prostheses. Two-year clinical and roentgenographic results of 100 cases. , 1990, Clinical orthopaedics and related research.
[113] K. Søballe,et al. The current status of hydroxyapatite coating of prostheses. , 1996, The Journal of bone and joint surgery. British volume.
[114] R. Geesink. Hydroxyapatite-coated total hip protheses : two-year clinical roentenografic results of 100 cases , 1990 .
[115] C. V. van Blitterswijk,et al. Structural arrangements at the interface between plasma sprayed calcium phosphates and bone. , 1994, Biomaterials.
[116] B. C. Wang,et al. Plasma spraying of zirconia-reinforced hydroxyapatite composite coatings on titanium: Part I Phase, microstructure and bonding strength , 1997, Journal of materials science. Materials in medicine.
[117] S D Cook,et al. Hydroxylapatite coating of porous implants improves bone ingrowth and interface attachment strength. , 1992, Journal of biomedical materials research.
[118] T. Bauer. Hydroxyapatite: coating controversies. , 1995, Orthopedics.
[119] J J Callaghan,et al. The uncemented porous-coated anatomic total hip prosthesis. Two-year results of a prospective consecutive series. , 1988, The Journal of bone and joint surgery. American volume.
[120] J. Chae,et al. Macroscopic and microscopic evidence of prosthetic fixation with porous-coated materials. , 1988, Clinical orthopaedics and related research.
[121] G. Delange,et al. Structure of the bone interface to dental implants in vivo. , 1993 .
[122] A. Yee,et al. A randomized trial of hydroxyapatite coated prostheses in total hip arthroplasty. , 1999, Clinical orthopaedics and related research.
[123] K. Bachus,et al. Porous-Coated Metal-Backed Patellar Components in Total Knee Replacement. A Postmortem Retrieval Analysis* , 1998, The Journal of bone and joint surgery. American volume.
[124] J. Weng,et al. Formation and characteristics of the apatite layer on plasma-sprayed hydroxyapatite coatings in simulated body fluid. , 1997, Biomaterials.
[125] W. Capello,et al. Hydroxyapatite-Coated Total Hip Femoral Components in Patients Less Than Fifty Years Old. Clinical and Radiographic Results after Five to Eight Years of Follow-up* , 1997, The Journal of bone and joint surgery. American volume.
[126] S D Cook,et al. In vivo mechanical and histological characteristics of HA-coated implants vary with coating vendor. , 1995, Journal of biomedical materials research.
[127] Y. Kim,et al. Uncemented porous-coated anatomic total hip replacement. Results at six years in a consecutive series. , 1993, The Journal of bone and joint surgery. British volume.
[128] B C Wang,et al. The shear strength and the failure mode of plasma-sprayed hydroxyapatite coating to bone: the effect of coating thickness. , 1993, Journal of biomedical materials research.
[129] G. Böhm,et al. Histology of tissue adjacent to an HAC-coated femoral prosthesis. A case report. , 1994, The Journal of bone and joint surgery. British volume.
[130] C. Berndt,et al. Optimization of spraying parameters for hydroxyapatite , 1991 .
[131] E. Evans. Toxicity of hydroxyapatite in vitro: the effect of particle size. , 1991, Biomaterials.
[132] K. Bachus,et al. Dissolution of particulate hydroxyapatite in a macrophage organelle model. , 1998, Journal of biomedical materials research.
[133] Y.H. Kim,et al. Uncemented porous-coated anatomic total hip replacement , 1993 .
[134] H. Cameron. Bone Implant Interface , 1994 .
[135] A. Edidin,et al. Fixation of Acetabular Cups without Cement in Total Hip Arthroplasty. A Comparison of Three Different Implant Surfaces at a Minimum Duration of Follow-up of Five Years* , 1998, The Journal of bone and joint surgery. American volume.
[136] C. Bünger,et al. Tissue ingrowth into titanium and hydroxyapatite‐coated implants during stable and unstable mechanical conditions , 1992, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[137] C. Bünger,et al. Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs. , 1992, Acta orthopaedica Scandinavica.
[138] C. Engh,et al. Histologic analysis of a retrieved microporous-coated femoral prosthesis. A seven-year case report. , 1987, Clinical orthopaedics and related research.
[139] J. Jansen,et al. A histological and histomorphometrical investigation of fluorapatite, magnesiumwhitlockite, and hydroxylapatite plasma-sprayed coatings in goats. , 1993, Journal of biomedical materials research.
[140] W. E. Brown,et al. The crystal structure of a-Ca3(PO4)2 , 1977 .
[141] J. Trombe,et al. Some features of the incorporation of oxygen in different oxidation states in the apatitic lattice—I On the existence of calcium and strontium oxyapatites , 1978 .
[142] S. Stea,et al. Improvement of the bone-pin interface with hydroxyapatite coating: an in vivo long-term experimental study. , 1996, Journal of orthopaedic trauma.
[143] S. Toksvig-Larsen,et al. A Comparison of Hydroxyapatite-Coated, Titanium-Coated, and Uncoated Tapered External-Fixation Pins. An in Vivo Study in Sheep* , 1998, The Journal of bone and joint surgery. American volume.
[144] C. Bünger,et al. Hydroxyapatite coating converts fibrous tissue to bone around loaded implants. , 1993, The Journal of bone and joint surgery. British volume.
[145] L. Dorr,et al. Hydroxyapatite-coated proximal ingrowth femoral stems. A matched pair control study. , 1995, Clinical orthopaedics and related research.
[146] S D Cook,et al. A comparison of three varieties of noncemented porous-coated hip replacement. , 1990, The Journal of bone and joint surgery. British volume.
[147] K. Khor,et al. The production and characterization of hydroxyapatite (HA) powders , 1999 .
[148] C. Colwell,et al. Omnifit-HA stem in total hip arthroplasty. A 2- to 5-year followup. , 1999, Clinical orthopaedics and related research.
[149] O. Sbaizero,et al. Mechanical and chemical consequences of the residual stresses in plasma sprayed hydroxyapatite coatings. , 1997, Biomaterials.
[150] P. Klopper,et al. Tissue response to dense apatite implants in rats. , 1980, Journal of biomedical materials research.
[151] Saadoun Ap,et al. Clinical results and guidelines on Steri-Oss endosseous implants. , 1992 .
[152] P. Branemark. Osseointegration and its experimental background. , 1983, The Journal of prosthetic dentistry.
[153] A. Piattelli,et al. Bone-hydroxyapatite interface in retrieved hydroxyapatite-coated titanium implants: a clinical and histologic report. , 1999, The International journal of oral & maxillofacial implants.
[154] S. Cook,et al. The effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants. , 1995, The Journal of bone and joint surgery. American volume.
[155] R. E. Jensen,et al. Loss of hydroxyapatite coating on retrieved, total hip components. , 1993, The Journal of arthroplasty.
[156] P. Buma,et al. Tissue reactions around a hydroxyapatite-coated hip prosthesis. Case report of a retrieved specimen. , 1995, The Journal of arthroplasty.
[157] J. Elliott,et al. Structure and chemistry of the apatites and other calcium orthophosphates , 1994 .
[158] L. Dorr,et al. Postmortem Analysis of Bone Growth into Porous-Coated Acetabular Components* , 1997, The Journal of bone and joint surgery. American volume.
[159] T. Bauer,et al. Hydroxyapatite-coated femoral stems. Histological analysis of components retrieved at autopsy. , 1991, The Journal of bone and joint surgery. American volume.
[160] L. Claes,et al. Increase of stability in external fracture fixation by hydroxyapatite-coated bone screws. , 1995, Journal of applied biomaterials : an official journal of the Society for Biomaterials.
[161] Johnson Bw. HA-coated dental implants: long-term consequences. , 1992 .
[162] E R Valstar,et al. The Effect of Hydroxyapatite on the Micromotion of Total Knee Prostheses. A Prospective, Randomized, Double-Blind Study* , 1998, The Journal of bone and joint surgery. American volume.
[163] C. Berndt,et al. In vitro changes of hydroxyapatite coatings. , 1997, The International journal of oral & maxillofacial implants.
[164] S. Medendorp,et al. An indirect comparison of third-body wear in retrieved hydroxyapatite-coated, porous, and cemented femoral components. , 1994, Clinical orthopaedics and related research.
[165] C. Misch,et al. BONE‐GRAFTING MATERIALS IN IMPLANT DENTISTRY , 1993, Implant dentistry.
[166] W. Capello,et al. Hydroxyapatite in Total Hip Arthroplasty: Clinical Results and Critical Issues , 1998, Clinical orthopaedics and related research.
[167] H. Haanaes,et al. A comparative clinical study of three different endosseous implants in edentulous mandibles. , 1998, The International journal of oral & maxillofacial implants.
[168] W. Harris,et al. The problem is osteolysis. , 1995, Clinical orthopaedics and related research.
[169] E. Chao,et al. Analysis of the external fixator pin-bone interface. , 1993, Clinical orthopaedics and related research.
[170] C. B. Ponton,et al. Microstructural characterization of hydroxyapatite coating on titanium , 1992 .