In vivo dosimetry with optically stimulated luminescent dosimeters for conformal and intensity-modulated radiation therapy: A 2-year multicenter cohort study.

PURPOSE Optically stimulated luminescent dosimeters (OSLDs) are utilized for in vivo dosimetry (IVD) of modern radiation therapy techniques such as intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). Dosimetric precision achieved with conventional techniques may not be attainable. In this work, we measured accuracy and precision for a large sample of clinical OSLD-based IVD measurements. METHODS AND MATERIALS Weekly IVD measurements were collected from 4 linear accelerators for 2 years and were expressed as percent differences from planned doses. After outlier analysis, 10,224 measurements were grouped in the following way: overall, modality (photons, electrons), treatment technique (3-dimensional [3D] conformal, field-in-field intensity modulation, inverse-planned IMRT, and VMAT), placement location (gantry angle, cardinality, and central axis positioning), and anatomical site (prostate, breast, head and neck, pelvis, lung, rectum and anus, brain, abdomen, esophagus, and bladder). Distributions were modeled via a Gaussian function. Fitting was performed with least squares, and goodness-of-fit was assessed with the coefficient of determination. Model means (μ) and standard deviations (σ) were calculated. Sample means and variances were compared for statistical significance by analysis of variance and the Levene tests (α = 0.05). RESULTS Overall, μ ± σ was 0.3 ± 10.3%. Precision for electron measurements (6.9%) was significantly better than for photons (10.5%). Precision varied significantly among treatment techniques (P < .0001) with field-in-field lowest (σ = 7.2%) and IMRT and VMAT highest (σ = 11.9% and 13.4%, respectively). Treatment site models with goodness-of-fit greater than 0.90 (6 of 10) yielded accuracy within ±3%, except for head and neck (μ = -3.7%). Precision varied with treatment site (range, 7.3%-13.0%), with breast and head and neck yielding the best and worst precision, respectively. Placement on the central axis of cardinal gantry angles yielded more precise results (σ = 8.5%) compared with other locations (range, 10.5%-11.4%). CONCLUSIONS Accuracy of ±3% was achievable. Precision ranged from 6.9% to 13.4% depending on modality, technique, and treatment site. Simple, standardized locations may improve IVD precision. These findings may aid development of patient-specific tolerances for OSLD-based IVD.

[1]  B J Mijnheer,et al.  In vivo dosimetry during external photon beam radiotherapy. , 1999, International journal of radiation oncology, biology, physics.

[2]  D. Followill,et al.  Angular dependence of the nanoDot OSL dosimeter. , 2011, Medical physics.

[3]  N. Draper,et al.  Applied Regression Analysis. , 1967 .

[4]  Jean M Moran,et al.  Dose discrepancies in the buildup region and their impact on dose calculations for IMRT fields. , 2010, Medical physics.

[5]  P. Higgins,et al.  In vivo diode dosimetry for routine quality assurance in IMRT. , 2003, Medical physics.

[6]  J. Gasiot,et al.  Optically Stimulated Luminescence Dosimetry , 1983 .

[7]  Lakhwant Singh,et al.  Verification of IMRT dose calculations using AAA and PBC algorithms in dose buildup regions , 2010, Journal of applied clinical medical physics.

[8]  T. Nyholm,et al.  A practical approach to diode based in vivo dosimetry for intensity modulated radiotherapy. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  In vivo diode dosimetry for IMRT treatments generated by Pinnacle treatment planning system. , 2009, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[10]  Michel Rouzaud,et al.  In vivo quality assurance of volumetric modulated arc therapy for ano-rectal cancer with thermoluminescent dosimetry and image-guidance. , 2014, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[11]  D Huyskens,et al.  Practical guidelines for routine intensity-modulated radiotherapy verification: pre-treatment verification with portal dosimetry and treatment verification with in vivo dosimetry. , 2010, The British journal of radiology.

[12]  Michael F. Weber,et al.  In vivo prostate IMRT dosimetry with MOSFET detectors using brass buildup caps , 2006, Journal of applied clinical medical physics.

[13]  A. Olch,et al.  Validation of OSLD and a treatment planning system for surface dose determination in IMRT treatments. , 2014, Medical physics.

[14]  Ben Mijnheer,et al.  In vivo dosimetry in external beam radiotherapy. , 2013, Medical physics.

[15]  Z Kusić,et al.  Optically stimulated luminescence in vivo dosimetry for radiotherapy: physical characterization and clinical measurements in 60Co beams , 2011, Physics in medicine and biology.

[16]  J. Palta,et al.  Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40. , 1994, Medical physics.

[17]  Bernard R. Rosner,et al.  Fundamentals of Biostatistics. , 1992 .

[18]  S. Kraft,et al.  Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors. , 2012, Medical physics.

[19]  C. Reft The energy dependence and dose response of a commercial optically stimulated luminescent detector for kilovoltage photon, megavoltage photon, and electron, proton, and carbon beams. , 2009, Medical physics.

[20]  Alain Noel,et al.  Detection of errors in individual patients in radiotherapy by systematic in vivo dosimetry , 1995 .

[21]  Timothy C. Zhu,et al.  Diode in Vivo Dosimetry for Patients Receiving External Beam Radiation Therapy , 2005 .

[22]  P. Jursinic,et al.  Characterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurements. , 2007, Medical physics.

[23]  L A R da Rosa,et al.  Radiotherapy dosimetry using a commercial OSL system. , 2008, Medical physics.

[24]  J. Palta,et al.  Dose variations with varying calculation grid size in head and neck IMRT , 2006, Physics in medicine and biology.

[25]  P. Jursinic Changes in optically stimulated luminescent dosimeter (OSLD) dosimetric characteristics with accumulated dose. , 2009, Medical physics.